03.120.30;17.020 标准查询与下载



共找到 69 条与 相关的标准,共 5

This standard is Capability of detection - Part 2: Methodology in the linear calibration case; Technical Corrigendum 1

Capability of detection - Part 2: Methodology in the linear calibration case; Technical Corrigendum 1

ICS
03.120.30;17.020
CCS
A41
发布
2007-10
实施

この規格は,校正用数(検量線)が直線であり,かつ,残差根準偏差の値と正味状態変数の と値の間に特定の 係がある,というJIS Z 8462-2の前提条件を仮定しない場合の測定方法の検出的カの評価について規定する。

Capability of detection -- Part 4: Methodology for comparing the minimum detectable value with a given value

ICS
03.120.30;17.020
CCS
A50;N04
发布
2006-11-20
实施

Capability of detection - Part 2: Methodology in the linear calibration case (ISO 11843-2:2000; text in German, English)

ICS
03.120.30;17.020
CCS
N04
发布
2006-06
实施

The standard deals with methods for determining values of the capability of detection and defines a criterion to decide whether or not the minimum detectable value of the net state variable is below a specified value.

Capability of detection - Part 4: Methodology for comparing the minimum detectable value with a given value (ISO 11843-4:2003; text in German, English)

ICS
03.120.30;17.020
CCS
N04
发布
2006-06
实施

この規格は,合理的に予想されるほとんどの目的に適合し,正味の状態変数の値がゼロになるように選ぱれた参照状態に対し,その参照状態で繰り返し測定して 得た測定値の平均値及び標準偏差から,応答変数の限界値について推定する方法(5.1を参照)を規定する。

Capability of detection -- Part 3: Methodology for determination of the critical value for the response variable when no calibration data are used

ICS
03.120.30;17.020
CCS
A50
发布
2006-01-20
实施

This standard is about Accuracy (trueness and precision) of measurement methods and results - Part 5: Alternative methods for the determination of the precision of a standard measurement method; Technical Corrigendum 1

Accuracy (trueness and precision) of measurement methods and results - Part 5: Alternative methods for the determination of the precision of a standard measurement method; Technical Corrigendum 1

ICS
03.120.30;17.020
CCS
N04
发布
2005-08
实施

This Technical Report provides users with practical guidance to the use of ISO 5725-2:1994 and presents simplified step-by-step procedures for the design, implementation, and statistical analysis of inter-laboratory studies for assessing the variability of a standard measurement method and on the determination of repeatability and reproducibility of data obtained in inter-laboratory testing.

Accuracy (trueness and precision) of measurement methods and results - Practical guidance for the use of ISO 5725-2:1994 in designing, implementing and statistically analysing interlaboratory repeatability and reproducibility results

ICS
03.120.30;17.020
CCS
N04
发布
2005-01
实施

Statistical methods. Capability of detection. Methodology for determination of the critical value for the response variable when no calibration data are used

ICS
03.120.30;17.020
CCS
发布
2005
实施
2007-01-01

Statistical methods. Capability of detection. Methodology for comparing the minimum detectable value with a given value

ICS
03.120.30;17.020
CCS
发布
2005
实施
2007-01-01

Capability of detection - Part 4 : methodology for comparing the minimum detectable value with a given value.

ICS
03.120.30;17.020
CCS
N04
发布
2004-03-01
实施
2004-03-20

This part of ISO 11843 deals with the assessment of the capability of detection of a measurement method without the assumptions in ISO 11843-2 of a linear calibration curve and certain relationships between the residual standard deviation and the value of the net state variable NOTE These assumptions are often doubtful for values of the net state variable close to zero. Instead of estimating the minimum detectable value, this part of ISO 11843 provides . a criterion for judging whether the minimum detectable value is less than a given level of the net state variable, and . the basic experimental design for testing the conformity of this criterion. For asses

Capability of detection - Part 4: Methodology for comparing the minimum detectable value with a given value

ICS
03.120.30;17.020
CCS
发布
2004-02-12
实施
2004-01-16

This part of ISO 11843 specifies basic methods to: - design experiments for the estimation of the critical value of the net state variable, the critical value of the response variable and the minimum detectable value of the net state variable, - estimate the characteristics from experimental data for the cases in which the calibration function is linear and the standard deviation is either constant or linearly related to the net state variable. The methods described in this part of ISO 11843 are applicable to various situations such as checking the existence of a certain substance in a material, the emission of energy from samples or plants, or the geometri

Capability of detection - Part 2: Methodology in the linear calibration case

ICS
03.120.30;17.020
CCS
发布
2003-12-11
实施
2003-08-27

This part of ISO 11843 gives a method of estimating the critical value of the response variable from the mean and standard deviation of repeated measurements of the reference state in certain situations (see 5.1) in which the value of the net state variable is zero, for all reasonable and foreseeable purposes. Hence, it can be decided whether values of the response variable in an actual state (or test sample) are above the range of values attributable to the reference state. General procedures for determination of critical values of the responses variable and the net state variable and of the minimum detectable value have been given in ISO 11843-2. Those pr

Capability of detection - Part 3: Methodology for determination of the critical value for the response variable when no calibration data are used

ICS
03.120.30;17.020
CCS
发布
2003-12-11
实施
2003-08-27

This International Standard is applicable to screens with height and length greater than 1,5 m. However, it may also be used for smaller screens provided that the interested parties come to an agreement on this.

Capability of detection - Methodology for comparing the minimum detectable value with a given value

ICS
03.120.30;17.020
CCS
N04
发布
2003-11-21
实施
2003-11-21

This part of ISO 11843 deals with the assessment of the capability of detection of a measurement method without the assumptions in ISO 11843-2 of a linear calibration curve and certain relationships between the residual standard deviation and the value of the net state variable NOTE These assumptions are often doubtful for values of the net state variable close to zero. Instead of estimating the minimum detectable value, this part of ISO 11843 provides — a criterion for judging whether the minimum detectable value is less than a given level of the net state variable, and — the basic experimental design for testing the conformity of this criterion. For assessment of the capability of detection, for instance as part of the validation of a measurement method, it is often sufficient to confirm that the method has a minimum detectable value that is less than a given value.

Capability of detection - Part 4: Methodology for comparing the minimum detectable value with a given value

ICS
03.120.30;17.020
CCS
N04
发布
2003-11
实施

When assessing the performance of a screen located indoors, the room geometry and reflections from walls, ceilings and room fittings will influence the performance. As a consequence, the comparison of screen performance can only be made if the test conditions are identical.

Capability of detection - Methodology for determination of the critical value for the response variable when no calibration data are used

ICS
03.120.30;17.020
CCS
A00
发布
2003-09-11
实施
2003-09-11

Capability of detection - Part 3 : methodology for determination of the critical value for the response variable when no calibration data are used.

ICS
03.120.30;17.020
CCS
N04
发布
2003-09-01
实施
2003-09-05

This part of ISO 11843 gives a method of estimating the critical value of the response variable from the mean and standard deviation of repeated measurements of the reference state in certain situations (see 5.1) in which the value of the net state variable is zero, for all reasonable and foreseeable purposes. Hence, it can be decided whether values of the response variable in an actual state (or test sample) are above the range of values attributable to the reference state. General procedures for determination of critical values of the response variable and the net state variable and of the minimum detectable value have been given in ISO 11843-2. Those procedures are applicable in situations in which there is relevant straight-line calibration and the residual standard deviation of the measured responses is either constant or is a linear function of the net state variable. The procedure given in this part of ISO 11843 for the determination of the critical value of the response variable only is recommended for situations in which no calibration data are used. The distribution of data is assumed to be normal or near-normal. The procedure given in this part of ISO 11843 is recommended for situations in which it is difficult to obtain a large amount of the actual states although a large amount of the basic state can be prepared.

Capability of detection - Part 3: Methodology for determination of the critical value for the response variable when no calibration data are used

ICS
03.120.30;17.020
CCS
N00
发布
2003-04
实施

この規格は,次の目的のための基本的方法を規定する。

Capability of detection -- Part 2: Methodology in the linear calibration case

ICS
03.120.30;17.020
CCS
N04
发布
2003-03-20
实施

JIS Z 8402のこの部は,—標準測定方法の併行標準偏差及び再現標準偏差を求めるための基本的方法に対する代替方法,すなわち,水準分割計画及び不均質物質に関する計画の詳細—計算からデータを除外するための外れ値の検定を行うことなく精度評価実験の結 果を解折するロバストな方法,特にその詳細な適用方法を規定する。

Accuracy (trueness and precision) of measurement methods and results -- Part 5: Alternative methods for the determination of the precision of a standard measurement method

ICS
03.120.30;17.020
CCS
A20
发布
2002-07-20
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号