共找到 85 条与 相关的标准,共 6 页
This International Standard is applicable to type test methods which permit calibration and measurement of the effectiveness of radon daughters' compensation of radioactive aerosol monitors. This standard defines aerosol characteristics used in these tests and applies the following procedures: - test method permitting the measurement of the response of the monitor relative to alpha and/or beta defined radioactive aerosols; - test method permitting the measurement of the response of the monitor relative to radon daughter-defined aerosols; - test method permitting the measurement of the effectiveness of radon compensation; - test method permitting the measurement of the response of the monitor relative to a mixture of aerosols constituted by radon daughters and by alpha and/or beta radioactive emitters. In addition, it specifies the requirements for acceptance.
Radiation protection instrumentation - Calibration and verification of the effectiveness of radon compensation for alpha and/or beta aerosol measuring instruments - Test methods
The document deals with measurements of surface contamination on landvehicles, water- and aircrafts and their loadings in exceptional situations requiring radiation protection measures in the field of the radiation protection providence order or the disaster protection. It can also be used for informal measurements of surface contamination of persons and their clothings.#,,#
Measurements of surface contamination on vehicles and their loadings in exceptional situations requiring radiation protection measures
This standard is the responsibility of the Accredited Standards Committee N42 on Radiation Instrumentation. Committee N42 delegated the development of the standard to its Subcommittee N42.1 Drafts were reviewed by Committee N42, Subcommittee N42.1, and other interested parties, and the comments received were utilized in producing the standard as finally approved and discussed. Performance criteria contained in this standard were tested for applicability under the standard was approved by Committee N42 letter ballot of February 6, 1989.
Performance specifications for health physics instrumentation; portable instrumentation for use in extreme environmental conditions
Thermoluminescence Dosimetry: Environmental Applications, Performance, Testing
Specifies techniques and instrumentation for the measurement of potentially hazardous electromagnetic fields in both near-field and far-field situations in the frequency range 300 kHz to 100 GHz. Measurements are made of one or more components of the fie
Radiofrequency radiation - Principles and methods of measurement - 300 kHz to 100 GHz