Standards for Insulators - Composite Distribution Deadend Type

ICS
29.080.10
CCS
K48
发布
2012
实施

Line suspension polymeric rod insulators. General specifications

ICS
29.080.10
CCS
发布
2012
实施
2014-01-01

JB/T 11219的本部分规定了高压架空线路复合绝缘子串元件用端部装配件的型号、尺寸、技术要求、试验方法及包装和标识等内容。 本部分适用于交、直流高压架空线路复合绝缘子串元件使用压接工艺的端部装配件。

End fitting for composite insulator with a high voltage overhead line.Part 1:End fitting for string insulator units

ICS
29.080.10
CCS
K48
发布
2011-12-20
实施
2012-04-01

IEC/TR 62662:2010(E) presents an analysis of the risk of influencing factors for brittle fracture of composite insulators that are mostly loaded in the tensile mode (suspension and tension insulators). Guidance is given to reduce the risk of in-service brittle fractures.

Guidance for production, testing and diagnostics of polymer insulators with respect to brittle fracture of core materials

ICS
29.080.10
CCS
发布
2011-10-28
实施
-

Cette norme est basée sur le document LWIWG-02 (96), Line Post Composite Insulator for Overhead Distribution Lines, de l’Association canadienne de l’électricité (ACÉ) qui en a autorisé l’utilisation. 1 Domaine d’application 1.1 Cette norme s’applique aux isolateurs composites rigides à socle employés sur les lignes aériennes de transport dont la tension nominale est égale ou inférieure à 75 kV. Les isolateurs rigides à socle supportent les conducteurs de façon horizontale et de façon verticale. Ils sont exposés à des efforts de traction, en porte-à-faux et de compression. Les isolateurs composites sont conçus pour être utilisés dans un environnement où la température se situe entre –50 et 50 °C. 1.2 Cette norme traite des isolateurs composites à noyau, armatures métalliques, revêtement et jupes. Le noyau est constitué de fibres de verre imprégnées de résine. Le noyau est protégé au moyen d’un revêtement résistant aux UV. Les armatures métalliques sont en aluminium, en acier ou en fer. 1.3 Dans les normes CSA, le terme «doit» indique une exigence, c’est-à-dire une prescription que l’utilisateur doit respecter pour assurer la conformité à la norme ; «devrait» indique une recommandation ou ce qu’il est conseillé mais non obligatoire de faire ; et «peut» indique une possibilité ou ce qu’il est permis de faire. Les notes qui accompagnent les articles ne comprennent pas de prescriptions ni de recommandations. Elles servent à séparer du texte les explications ou les renseignements qui ne font pas proprement partie de la norme. Les notes au bas des figures et des tableaux font partie de ceux-ci et peuvent être rédigées comme des prescriptions. Les annexes sont qualifiées de normatives (obligatoires) ou d’informatives (facultatives) pour en préciser l’application.

Rigid composite base insulators for overhead transmission lines _< 75 kV

ICS
29.080.10
CCS
发布
2011-06-01
实施

Cette norme est basée sur le document LWIWG-03 (96), Guy Composite Insulator for Guy Wires, de l’Association canadienne de l’électricité (ACÉ) qui en a autorisé l’utilisation. 1 Domaine d’application 1.1 Cette norme s’applique aux isolateurs de hauban composites employés dans des haubans sur les lignes aériennes de transport dont la tension nominale est égale ou inférieure à 75 kV. Les isolateurs de hauban isolent les câbles de hauban et ont pour fonction d’assurer la protection contre la corrosion, un niveau d’isolement supérieur, les dégagements nécessaires à l’entretien et au fonctionnement normal et la sécurité du public et des travailleurs. Les isolateurs de hauban sont exposés à des efforts de traction et de torsion. Les isolateurs composites sont conçus pour être utilisés dans un environnement où la température se situe entre –50 et 50 °C. 1.2 Cette norme traite des isolateurs de hauban composites à noyau, armatures métalliques et enveloppe protectrice. Le noyau de l’isolateur est constitué de fibres de verre imprégnées de résine et est protégé au moyen d’un revêtement résistant aux UV. 1.3 Dans les normes CSA, le terme «doit» indique une exigence, c’est-à-dire une prescription que l’utilisateur doit respecter pour assurer la conformité à la norme ; «devrait» indique une recommandation ou ce qu’il est conseillé mais non obligatoire de faire ; et «peut» indique une possibilité ou ce qu’il est permis de faire. Les notes qui accompagnent les articles ne comprennent pas de prescriptions ni de recommandations. Elles servent à séparer du texte les explications ou les renseignements qui ne font pas proprement partie de la norme. Les notes au bas des figures et des tableaux font partie de ceux-ci et peuvent être rédigées comme des prescriptions. Les annexes sont qualifiées de normatives (obligatoires) ou d’informatives (facultatives) pour en préciser l’application.

Composite Stay Insulators

ICS
29.080.10
CCS
发布
2011-06-01
实施

Characteristic of indoor and outdoor post insulators for systems with nominal voltages greater than 1000 V

ICS
29.080.10
CCS
发布
2011
实施

Tests on indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V

ICS
29.080.10
CCS
发布
2011
实施

1 Domaine d’application 1.1 Cette norme s’applique aux isolateurs de suspension (éléments de chaîne) en verre durci ou en porcelaine fabriquée par procédé humide, conçus pour les réseaux aériens de courant alternatif, dont la tension nominale est supérieure à 1000 V et la fréquence ne dépasse pas 100 Hz. Cette norme s’applique aux isolateurs individuels et non aux isolateurs à long fût. 1.2 Cette norme prescrit les exigences visant a) les caractéristiques mécaniques, électriques et dimensionnelles des isolateurs et les conditions dans lesquelles les valeurs spécifiées de ces caractéristiques sont vérifiées ; et b) les méthodes d’essai et les critères d’acceptation. 1.3 Dans les normes CSA, le terme «doit» indique une exigence, c’est-à-dire une prescription que l’utilisateur doit respecter pour assurer la conformité à la norme ; «devrait» indique une recommandation ou ce qu’il est conseillé mais non obligatoire de faire ; et «peut» indique une possibilité ou ce qu’il est permis de faire. Les notes qui accompagnent les articles ne comprennent pas de prescriptions ni de recommandations. Elles servent à séparer du texte les explications ou les renseignements qui ne font pas proprement partie de la norme. Les notes au bas des figures et des tableaux font partie de ceux-ci et peuvent être rédigées comme des prescriptions. Les annexes sont qualifiées de normatives (obligatoires) ou d’informatives (facultatives) pour en préciser l’application.

Suspension insulators (chain elements)

ICS
29.080.10
CCS
发布
2010-09-01
实施

本标准规定了标称电压高于1000V的户外交、直流复合绝缘子用硅橡胶绝缘材料的技术要求、试验方法。 本标准适用于复合绝缘子用硅橡胶绝缘材料,不适用于硅油、硅脂、RTV涂料、环氧树脂、乙丙橡胶等绝缘材料。

General technical tequirements of silicone rubber insulation materials for composite insulators

ICS
29.080.10
CCS
K48
发布
2010-05-24
实施
2010-10-01

本标准规定了标称电压高于1000V交、直流输电线路用盘形悬式绝缘子在高海拔地区污秽条件下绝缘子污耐受电压和统一爬电比距的修正方法。 本标准适用于海拔高度1000m-5500m地区的盘形悬式绝缘子。支柱绝缘子和套管的污耐受电压和统一爬电比距的修正方法可参考本标准。

The correction of high altitude on pollution external insulation for insulators used in transmission line

ICS
29.080.10
CCS
K48
发布
2010-05-24
实施
2010-10-01

IEC 62223:2009 specifies terms defined in standards that fall under the scope of technical committee TC 36: Insulators. It covers terms that can be found in IEC 60050-471 as well as terms not appropriate for inclusion in IEC 60050-471 but used widely in the standards of IEC TC 36. IEC 60050-471 is not intended to cover all the terms used in the various IEC standards but provides rather a general purpose vocabulary giving the basic terms and reference terms to be used by all technical committees. This glossary is intended to harmonize terms not listed in IEC 60050-471 but used in the publications of committee TC 36.

Insulators - Glossary of terms and definitions

ICS
29.080.10
CCS
发布
2010-02-19
实施
2010-02-19

Composite string insulator units for overhead lines with a nominal voltage greater than 1 kV - Part 1: Standard strength classes and end fittings (IEC 61466-1:1997); German version EN 61466-1:1997, Corrigendum to DIN EN 61466-1 (VDE 0441-4):1997-10; (IEC-

ICS
29.080.10
CCS
K48
发布
2010-02
实施

Insulators - Glossary of terms and definitions (IEC 62223:2009)

ICS
29.080.10
CCS
发布
2010-01-29
实施
2010-01-29

IEC 62223:2009 specifies terms defined in standards that fall under the scope of technical committee TC 36: Insulators. It covers terms that can be found in IEC 60050-471 as well as terms not appropriate for inclusion in IEC 60050-471 but used widely in the standards of IEC TC 36. IEC 60050-471 is not intended to cover all the terms used in the various IEC standards but provides rather a general purpose vocabulary giving the basic terms and reference terms to be used by all technical committees. This glossary is intended to harmonize terms not listed in IEC 60050-471 but used in the publications of committee TC 36.

Insulators - Glossary of terms and definitions

ICS
29.080.10
CCS
发布
2009-11-27
实施
2009-12-01 (7)

Insulators for overhead lines - Insulator strings and sets for lines with a nominal voltage greater than 1000 V - AC power arc tests (IEC 61467:2008); German version EN 61467:2008

ICS
29.080.10
CCS
K48
发布
2009-08
实施
2009-08-01

1   Scope and object IEC/TS 60815‑1, which is a technical specification, is applicable to the selection of ceramic and glass insulators for a.c. systems, and the determination of their relevant dimensions, to be used in high-voltage systems with respect to pollution. This part of IEC 60815 gives specific guidelines and principles to arrive at an informed judgement on the probable behaviour of a given insulator in certain pollution environments. The basis for the structure and approach of this part of IEC 60815 is fully explained in IEC/TS 60815‑1. The object of this technical specification is to give the user means to: • determine the reference unified specific creepage distance ( RUSCD ) from site pollution severity ( SPS ) class; • evaluate the suitability of different insulator profiles; • determine the necessary USCD by applying corrections for insulator shape, size, position, etc. to the RUSCD ; • if required, determine the appropriate test methods and parameters to verify the performance of the selected insulators.

Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Ceramic and glass insulators for a.c. systems

ICS
29.080.10
CCS
发布
2009-06-30
实施
2009-06-30

What is DD IEC/TS 60815-3 - Polymer insulators for a.c. systems about?    DD IEC/TS 60815-3  is a technical specification with the objective to give the user the means to determine the reference unified specific creepage distance (USCD) from site pollution severity (SPS) class, choosing appropriate profiles, apply correction factors for altitude, insulator shape, size and position, etc. to the reference USCD.   DD IEC/TS 60815-3 is a part of the  IEC/TS 60815  series and gives specific guidelines and principles to arrive at an informed judgement on the probable behaviour of a given insulator in certain pollution environments. DD IEC/TS 60815-3  guideline is detailed information about the performance of insulators under pollution.  

Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Polymer insulators for a.c. systems

ICS
29.080.10
CCS
发布
2009-06-30
实施
2009-06-30

1   Scope and object IEC/TS 60815‑1, which is a technical specification, is applicable to the selection of insulators, and the determination of their relevant dimensions, to be used in high-voltage systems with respect to pollution. For the purposes of this technical specification, the insulators are divided into the following broad categories, each dealt with in a specific part as follows: — IEC/TS 60815‑2 – Ceramic and glass insulators for a.c. systems; — IEC/TS 60815‑3 – Polymeric insulators for a.c. systems; — IEC/TS 60815‑4 – equivalent to 60815-2 for d.c. systems 1 ; — IEC/TS 60815‑5 – equivalent to 60815-3 for d.c. systems 1 . This part of IEC 60815 gives general definitions, methods for the evaluation of pollution site severity ( SPS ) and outlines the principles to arrive at an informed judgement on the probable behaviour of a given insulator in certain pollution environments. This technical specification is generally applicable to all types of external insulation, including insulation forming part of other apparatus. The term “insulator” is used hereafter to refer to any type of insulator. CIGRE C4 documents [1], [2], [3] 2 , form a useful complement to this technical specification for those wishing to study in greater depth the performance of...

Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Definitions, information and general principles

ICS
29.080.10
CCS
发布
2009-06-30
实施
2009-06-30

""Is applicable for the determination of the power frequency withstand characteristics of ceramic and glass insulators to be used outdoors and exposed to polluted atmospheres, on a.c. systems with the highest voltage of the system ranging from 1 000 V up to 765 kV. These tests are not directly applicable to greased insulators or to special types of insulators (insulators with conductive glaze or covered with any organic insulating material).""

Artificial pollution tests on high-voltage insulators to be used on a.c. systems