共找到 1581 条与 消防设备与器材 相关的标准,共 106 页
Fixed fire protection systems. Industrial and commercial watermist systems. Code of practice for design and installation
Fixed fire protection systems. Industrial and commercial watermist systems. Fire performance tests and requirements for watermist systems for the protection of combustion turbines and machinery spaces with volumes up to and including 8...
Fixed fire protection systems. Industrial and commercial watermist systems. Tests and requirements for watermist systems for the protection of low hazard occupancies
Fixed fire protection systems. Industrial and commercial watermist systems. Fire performance tests and requirements for watermist systems for local applications involving flammable liquid fires
Fixed fire protection systems. Industrial and commercial watermist systems. Fire performance tests and requirements for watermist systems for the protection of industrial oil cookers
本标准规定了轻便消防水龙的术语和定义、分类、型号和基本参数、技术要求、试验方法、检验规则、标志、包装、运输及储存。 本标准适用于轻便消防水龙。
Portable fire hose
Firefighting and fire protection - Two-pole connector, 16 A, 42 V - Part 1: Socket, connector socket
Firefighting and fire protection - Two-pole connector, 16 A, 42 V - Part 2: Plug
本标准规定了七氟丙烷泡沫灭火系统及部件的术语和定义、分类和型号、技术要求、试验方法、检验规则、标志、包装、运输、贮存。 本标准适用于七氟丙烷泡沫灭火系统及部件。
Heptafluoropropane foam fire extinguishing system
Coupling spanner for fire fighting fittings - Part 2: Coupling spanner type ABC
Coupling spanner for fire fighting fittings - Part 1: Coupling spanner type BC
Fire fighting requirements and test methods for fire trucks
Portable equipment for projecting extinguishing agents supplied by fire fighting pumps - Portable foam equipment - Part 3: Low and medium expansion hand-held foam branchpipes PN 16; German version EN 16712-3:2015
Portable equipment for projecting extinguishing agents supplied by fire fighting pumps - Portable foam equipment - Part 1: Inductors PN 16; German version EN 16712-1:2015
Firefighting and rescue service vehicles - Part 3: Coloration and special markings
This part of ISO 4642 specifies the requirements and test methods for semi-rigid reel hoses for firefighting purposes for use with fixed systems. The hoses are intended for use at a maximum working pressure of 1,2 MPa for hoses of 19 mm and 25 mm inside diameter and 0,7 MPa for hoses of 33 mm inside diameter. Hoses conforming to this part of ISO 4642 are intended for applications where long intervals can occur between the occasions of use, for example on fixed fire hose reels in buildings and other construction works. This part of ISO 4642 applies exclusively to hoses for fire-fighting purposes intended for use at ambient conditions in non-aggressive or non-corrosive atmospheres within the temperature range −20 °C to +60 °C. NOTE 1 NOTE 2 Hoses for use at temperatures lower than −20 °C can be supplied at the request of the purchaser. All pressures are expressed in megapascals where 1 MPa = 10 bar.
Rubber and plastics hoses, non-collapsible, for fire-fighting service - Part 1: Semi-rigid hoses for fixed systems
Portable equipment for projecting extinguishing agents supplied by fire fighting pumps - Portable foam equipment - Part 2: Pick-up tubes; German version EN 16712-2:2015
Branchpipe-holder for nominal pressure 16
Portable fire extinguishers - Part 4: Maintenance; Supplement 1: Information for application
This part of ISO 4642 specifies the requirements and test methods for semi-rigid reel hoses for use on fire-fighting vehicles and trailer pumps. The hoses are intended for use at a maximum working pressure of 1,5 MPa for normal pressure hoses (category I) and 4,0 MPa for high pressure hoses (category II). The hoses are further subdivided into types and classes (see Clause 4). This part of ISO 4642 applies to delivery hoses for fire-fighting purposes intended for use at a minimum ambient temperature of −20 °C. Hoses conforming to this part of ISO 4642 are intended to be used with fire hose couplings conforming to the relevant national standards couplings. Requirements are also given for hose assemblies (see 6.12) where these are fitted by the hose manufacturer. NOTE 1 Hoses for use at temperatures lower than −20 °C can be supplied by agreement between the manufacturer and purchaser. NOTE 2 All pressures are expressed in megapascals where 1 MPa = 10 bar.
Rubber and plastics hoses, non-collapsible, for fire-fighting service - Part 2: Semi-rigid hoses (and hose assemblies) for pumps and vehicles