C84 消防设备与器材 标准查询与下载



共找到 1581 条与 消防设备与器材 相关的标准,共 106

La présente Norme européenne spécifie les exigences et méthodes d'essai applicables aux tuyaux semi-rigides de lutte contre l'incendie prévus pour des systèmes fixes. Les tuyaux ayant un diamètre intérieur de 19 mm ou de 25 mm sont prévus pour être utilisés à une pression maximale de service de 1,2 MPa et les tuyaux ayant un diamètre intérieur de 33 mm sont prévus pour être utilisés à une pression maximale de service de 0,7 MPa.

Fire-fighting hoses - Semi-rigid hoses for fixed systems

ICS
13.220.10;23.040.70
CCS
C84
发布
2014-09-27
实施
2014-09-27

Fire-fighting hoses - Semi-rigid delivery hoses and hose assemblies for pumps and vehicles; German version EN 1947:2014

ICS
13.220.10;23.040.70
CCS
C84
发布
2014-09-01
实施

Fire-fighting hoses - Non-percolating layflat hoses for fixed systems; German version EN 14540:2014

ICS
13.220.10;23.040.70
CCS
C84
发布
2014-09-01
实施

Fire-fighting hoses. Semi-rigid hoses for fixed systems

ICS
13.220.10;23.040.70
CCS
C84
发布
2014-08-31
实施
2014-08-31

Fire-fighting hoses - Semi-rigid delivery hoses and hose assemblies for pumps and vehicles

ICS
13.220.10
CCS
C84
发布
2014-08-30
实施
2014-08-30

La présente Norme européenne spécifie les exigences et méthodes d'essai applicables aux tuyaux aplatissables étanches prévus pour des systèmes fixes. Ces tuyaux sont destinés à être utilisés à une pression maximale de service de 1,5 MPa et leur diamètre doit être compris entre 25 mm et 52 mm.

Fire-fighting hoses - Non-percolating layflat hoses for fixed systems

ICS
13.220.10;23.040.70
CCS
C84
发布
2014-08-16
实施
2014-08-16

Pressure limitation valve, nominal pressure 16

ICS
13.220.10;23.060.40
CCS
C84
发布
2014-08-01
实施

Fire-fighting hoses. Semi-rigid delivery hoses and hose assemblies for pumps and vehicles

ICS
13.220.10;23.040.70
CCS
C84
发布
2014-07-31
实施
2014-07-31

Fire-fighting hoses. Non-percolating layflat hoses for fixed systems

ICS
13.220.10;23.040.70
CCS
C84
发布
2014-07-31
实施
2014-07-31

Mobile fire extinguishers - Part 2: Requirements for the construction, pressure resistance and mechanical tests for extinguishers, with a maximum allowable pressure equal to or lower than 30 bar, which comply with the requirements of EN 1866-1; German ver

ICS
13.220.10
CCS
C84
发布
2014-07
实施

This European Standard specifies the requirements and test methods for semi-rigid hoses for fire-fighting purposes for use with fixed systems. The hoses are intended for use at a maximum working pressure of 1,2 MPa for hoses of 19 mm and 25 mm inside diameter and 0,7 MPa for hoses of 33 mm inside diameter. Hoses conforming to this European Standard are intended for applications where long intervals can occur between the occasions of use, for example on fixed fire hose reels in buildings and other construction works. This European Standard applies exclusively to hoses for fire-fighting purposes intended for use at ambient conditions in non-aggressive or non-corrosive atmospheres within the temperature range -20 °C to +60 °C. NOTE 1 Hoses for use at ambient temperatures below -20°C can be supplied if they have been tested at the specified lower temperature in accordance with 6.4 and identified by their marking in Clause 8 f). NOTE 2 All pressures are expressed in megapascals. 1 MPa = 10 bar

Fire-fighting hoses - Semi-rigid hoses for fixed systems

ICS
13.220.10;23.040.70
CCS
C84
发布
2014-07
实施

This European Standard specifies the requirements and test methods for non-percolating layflat hoses for fixed systems. The hoses are intended for use at a maximum working pressure of 1,5 MPa over a range of inside diameters from 25 mm to 52 mm. This European Standard applies exclusively to hoses for fire-fighting purposes intended for use at a minimum ambient temperature of -20 °C in normal conditions, and a minimum temperature of -30 °C in colder climatic conditions and a maximum ambient temperature of +60 °C. Hoses conforming to this standard should be used with fire hose couplings conforming to the relevant national standards for couplings. NOTE 1 Hoses for use at ambient temperatures below -20 °C can be supplied if they have been tested at the specified lower temperature in accordance with 6.4 and identified by their marking in Clause 8 f). Hoses in marine applications and/or aggressive environments to be used with wall hydrants as specified in EN 671-2 can conform to the requirements of this standard. NOTE 2 All pressures are gauge pressures and are expressed in megapascals.

Fire-fighting hoses - Non-percolating layflat hoses for fixed systems

ICS
13.220.10;23.040.70
CCS
C84
发布
2014-07
实施

本标准规定了探火管式灭火装置的术语和定义、分类、型号编制、要求、试验方法、检验规则、标志、包装、运输、贮存和使用说明书编写要求等。

Extinguishing equipment with fire detection tube

ICS
13.220.10
CCS
C84
发布
2014-06-23
实施
2014-07-01

Mobile fire extinguishers. Requirements for the construction, pressure resistance and mechanical tests for extinguishers, with a maximum allowable pressure equal to or lower than 30 bar, which comply with the requirements of EN 1866-1

ICS
13.220.10
CCS
C84
发布
2014-05-31
实施
2014-05-31

本标准规定了细水雾灭火装置的术语和定义、分类与型号、基本参数、要求、试验方法、检验规则、标志和使用说明书。本标准适用于细水雾灭火装置。

Water mist extinguishing equipment

ICS
13.220.10
CCS
C84
发布
2014-05-21
实施
2014-05-21

This part of ISO 6182 specifies performance requirements, test methods, and marking requirements for domestic sprinklers. These sprinklers are intended to provide control of fires in domestic occupancies, to prevent flashover (total involvement) in the room of fire origin and to improve the probability for successful escape or evacuation of the occupants.

Fire protection - Automatic sprinkler systems - Part 10: Requirements and test methods for domestic sprinklers

ICS
13.220.20
CCS
C84
发布
2014-05-01
实施

This part of ISO 7076 specifies reduirements, test and assessment methods, and performance criteria for fixed compressed air foam equipment of fixed foam extinguishing Systems for indoor or outdoor utilization, Or both. Technical safety redquirements concerning the design andmanufacturing ofdrives, auxiliary equipment, Sources of energy or pumps are outside the scope ofthis part of ISO 7076. Special hazards arising from the particular conditions under which these Systems are used are outside the scope ofthis part of ISO 7076. Hazards relating to anykind ofmechanical electrical hydraulic pneumatic, and other equipment dealt with by the respective standards for such eduipment are outside the scope ofthis part of ISO 7076. Hazards arising from the noise of systems are outside the scope ofthis part of ISO 7076.

Fire protection - Foam fire extinguishing systems - Part 5: Fixed compressed air foam equipment

ICS
13.220.10
CCS
C84
发布
2014-05
实施

This European Standard specifies the rules of design, type testing, manufacturing and inspection during manufacturing of mobile fire extinguishers with metallic bodies, which comply with the requirements of EN 1866-1, as far as pressure resistance is concerned. This part applies to mobile fire extinguishers of which the maximum allowable pressure PS is lower than or equal to 30 bar and containing non-explosive, non-flammable, non-toxic and non-oxidizing fluids or powder. This European Standard does not apply to carbon dioxide fire extinguishers.

Mobile fire extinguishers - Part 2: Requirements for the construction, pressure resistance and mechanical tests for extinguishers, with a maximum allowable pressure equal to or lower than 30 bar, which comply with the requirements of EN 1866-1

ICS
13.220.10
CCS
C84
发布
2014-05
实施

UL Standard for Safety Fixed Condensed Aerosol Extinguishing System Units (First Edition; Reprint with revisions through and including August 5, 2016)

ICS
CCS
C84
发布
2014-04-03
实施

High rise aerial appliances for fire and rescue service use - Turntable ladders with combined movements - Safety and performance requirements and test methods; German version EN 14043:2014

ICS
13.220.10
CCS
C84
发布
2014-04
实施
2014-04-01



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号