本标准规定了广东省内锅炉的停(备)用防锈蚀保养的基本要求、方法以及选用方法的原则。本标准适用于广东省内《特种设备安全监察条例》所规定的锅炉停(备)用防锈蚀保养。
The Technical Condition for Lay-off,Standby Conservation of Boiler
이 규격은 최고 사용 압력 100 kPa{1 kgf/cm2} 이하의 온수용 열교환기의 온수
Relief valves for hot water appliances
이 규격은 주로 등유, 경유 등을 연료로 하는 건타입 기름 버너에 사용되는 연소용 송풍기,
Combustion safety controllers for gun type oil burners
이 규격은 동관, 알루미늄 핀(fin)으로 구성되어 있는 엘리먼트(열교환부)를 대류 작용을
Convector
This part of ISO 15547 contains requirements and recommendations for the mechanical design, materials selection, fabrication, inspection, testing and preparation for shipment of brazed aluminium plat-fin heat exchangers, for use in petroleum, petrochemical and natural gas industries.
Petroleum, petrochemical and natural gas industries - Plate-type heat exchangers - Part 2: Brazed aluminium plate-fin heat exchangers (ISO 15547-2:2005); English version EN ISO 15547-2:2005
Petroleum, petrochemical and natural gas industries - Plate-type heat exchangers - Part 1: Plate-and-frame heat exchangers (ISO 15547-1:2005); English version EN ISO 15547-1:2005
Methodology and Application of Simulated Wind-Driven Rain Infiltration in Building Envelope Experimental Testing
Methodology and Application of Simulated Wind-Driven Rain Infiltration in Building Envelope Experimental Testing
Distribution of Water between Vapor and Liquid Phases of Refrigerants See Technical Paper 4845, P.241
Distribution of Water between Vapor and Liquid Phases of Refrigerants See Technical Paper 4845, P.241
Infiltration Heat Recovery, Part I - Field Studies in an Instrumented Test Building RP-1169
Infiltration Heat Recovery, Part I - Field Studies in an Instrumented Test Building RP-1169
1.1 This specification establishes the requirements for copper-beryllium alloy UNS No. C17510 welded tube in straight lengths.1.2 UnitsThe values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units, which are provided for information only and are not considered standard.This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Standard Specification for Copper-Beryllium Welded Heat Exchanger and Condenser Tube (UNS No. C17510)
1.1 This specification establishes the requirements for copper-beryllium alloy UNS No. C17510 welded tube in straight lengths. 1.2 Units8212;The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units, which are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Standard Specification for Copper-Beryllium Welded Heat Exchanger and Condenser Tube (UNS No. C17510)
The document establishes uniform test methods to ascertain perfomance data as product identification, performance characteristics, pressure drop.
Heat exchangers - Water to water heat exchangers for district heating - Test procedures for establishing the performance data; English version of DIN EN 1148:1998/A1:2005
Heat exchangers - Method of measurement and evaluation of thermal performances of wet cooling towers.
This European Standard specifies requirements, test methods and acceptance tests for thermal performances pumping head verification of wet cooling towers and plume abatement for wet/dry cooling towers. This European Standard is applicable to natural draught wet cooling towers (see in 3.1.2.2) fan assisted natural draught cooling tower (see 3.1.2.3), wet/dry cooling towers (see 3.1.2.4) and "Mechanical draught cooling towers", except series ones. It specifies the test methods, the apparatus required, the limitation of errors and the method for results examination. The acceptance testing covers the verification of the thermal performance data and pumping head of the cooling tower as specified in the contract between the supplier and the purchaser. If these tests are required then this should be recognized at the time of the contract, as additional fittings, and preparations for the test may be required. Deviations from the rules laid down below as well as additions need special agreement between purchaser and supplier and should be documented. This standard does not apply to mechanical draught series wet cooling towers which are dealt with in EN 13741. NOTE Terms like "design", "values", "guarantee" and "acceptance" used in this standard should be understood in a technical but not in a legal or commercial sense.
Heat exchangers - Method of measurement and evaluation of thermal performances of wet cooling towers
Heating and Cooling Equipment Third Edition
Heating and cooling equipment Third Edition; Update No.2: July 2009
The purpose of this standard is to establish for Direct Geoexchange Heat Pumps: definitions; classification; test and rating requirements; minimum data requirements for Published Ratings; operating requirements; marking and nameplate data; and conformance conditions.
Performance Rating of Direct Geoexchange Heat Pumps
The activities above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at h_t_t_p_:_/_/_a_s_s_i_s_t_._d_a_p_s_._d_l_a_._m_i_l_
GRINDING MACHINES, SURFACE, RECIPROCATING TABLE, HORIZONTAL SPINDLE, HAND FEED
Heat exchangers - Forced convection air cooled refrigerant condensers and dry coolers - Sound measurement.
MIL-PRF-62411A, dated 7 July 1997, has been reviewed and determined to be valid for use in acquisition
HEAT EXCHANGER, NBC SYSTEM GENERAL SPECIFICATION FOR
本标准规定了板式换热机组的型号编制.基本参数、技术要求、.试验方法和检验规 则,标志、包装、运输和贮存要求。 本标准适用于供热,空调及生活热水等换热系统中使用的板式换热机组。
Plate heat exchanger units