1.1 This specification covers stranded conductors made from round copper wires, either uncoated or coated with tin, lead, or lead alloy for general use in insulated conductor assemblies for electrical purposes. These conductors shall be composed of one or more roller shaped or die closed layers of helically laid wires using the single input wire (SIW) methodology. (see Note 1 and Explanatory Note 1) Note 18212;Sealed conductors which are intended to prevent longitudinal water propagation and are further covered/insulated, are also permitted within the guidelines of this specification. 1.2 The values stated in inch-pound or SI units are to be regarded separately as standard. The values in each system are not exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification. 1.2.1 For density, resistivity, and temperature, the values stated in SI units are to be regarded as standard.

Standard Specification for Compressed Round Stranded Copper Conductors, Hard, Medium-Hard, or Soft Using Single Input Wire Construction

ICS
29.060.10
CCS
K11
发布
2004
实施

ERRATUM

ICS
CCS
K11
发布
2003-10-06
实施

この規格は,主として機器用配線及び屋内配線に使用する軟銅のより線又は単線の電線相互を接続するために,JIS C 9711(屋内配線用電線接続工具)に規定する接続工具又は裸圧着スリープの製造業者が指定する接続工具(以下,工具という。)(1)を用いて,その電線相互を圧着接続する裸圧着スリープ(以下,スリーブという。)について規定する。注(1)直線突合せ用スリープ及び直線重合せ用スリーブの接続には,裸圧着端子用工具を,終端重合せ用スリープの接続には,手動片手式のリングスリープ用工具を用いる。

Non-insulated crimp-type sleeves for copper conductors

ICS
29.120.20
CCS
K11
发布
2003-06-20
实施

이 규격은 전력 전송용 가공 선로로 연합한 도체의 제조에 관한 경알루미늄선에 적용한다.

Hard-drawn aluminium wire for overhead line conductors

ICS
29.240.20;29.060.10
CCS
K11
发布
2003-05-20
实施
2003-05-20

Applies to uninsulated stranded hard-drawn aluminium conductors, steel reinforced, for overhead transmission lines.

Conductors for overhead electrical transmission lines Part 3: Aluminium conductors, steel reinforced

ICS
29.240.20
CCS
K11
发布
2003-05-16
实施

本标准描述了运用直流或低扫场速率磁强计方法对Cu/Nb-Ti多丝复合线磁滞损耗进行测量的相 关事宜。本标准所针对的是Cu/Nb-Ti多丝复合导体中磁滞损耗的测量。测量应在4.2 K或4.2 K附 近的温度下针对圆形线进行。直流或低扫场速率磁强计法使用的是超导量子干涉器件(SQUID)磁强 计或振动样品磁强计(VSM)。如果测量中发现用不同的(但均校准过的)磁强计所得的结果存在差异, 则以VSM在外推至零扫场速率下测量的结果为准。

Superconductivity - Part 13: AC loss measurements; Magnetometer methods for hysteresis loss in Cu/Nb-Ti multifilamentary composites

ICS
29.050
CCS
K11
发布
2003-05
实施
2003-05-21

本标准对光纤复合架空地线 (Optical fiber composite overhead ground wires,以下簡稱 OPGW) 的 产品型号、结构、技术要求、特性参数、相应的试验方法和验收规则、包装、运输贮存、安装建议以 及使用说明书进行了规范要求。 本标准适用于光纤复合架空地线 (OPGW) 。

Optical fiber composite overhead ground wires

ICS
29.060.01
CCS
K11
发布
2003-01-09
实施
2003-06-01

1.1 This specification covers shaped wire compact concentric-lay-stranded aluminum conductor, steel-reinforced (ACSR/TW) and its component wires for use as overhead electrical conductors (Explanatory Note 1 and Note 2). 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. Note 18212;ACSR/TW is designed to increase the aluminum area for a given diameter of conductor by the use of trapezoidally shaped wires (TW). The conductors consist of a central core of round steel wire(s) surrounded by two or more layers of trapezoidal aluminum 1350-H19 wires. Different strandings of the same size of conductor are identified by type, which is the approximate ratio of steel area to aluminum area expressed in percent (Table 1, Table 2 and Table 3). For the purpose of this specification, the sizes listed in Table 1 and Table 2 are tabulated on the basis of the finished conductor having an area or outside diameter equal to that of specific sizes of standard ACSR so as to facilitate conductor selection. Note 28212;The aluminum and temper designations conform to ANSI Standard H 35.1. Aluminum 1350 corresponds to Unified Numbering System (UNS) A91350 in accordance with Practice E 527.

Standard Specification for Shaped Wire Compact Concentric-Lay-Stranded Aluminum Conductors, Steel-Reinforced (ACSR/TW)

ICS
29.240.20 (Power transmission and distribution lin
CCS
K11
发布
2003
实施

1.1 This specification covers bare bunch-stranded and rope-lay bunch-stranded conductors made from round copper wires finer than No. 40 AWG with diameters less than 0.0031 in. (.078 mm), either coated or uncoated with tin or silver, for use as electrical conductors. (Explanatory Note 1). 1.2 The values (SI units) for density and temperature are regarded as the standard. For all other properties the inch-pound values are to be regarded as standard, and the SI units may be approximate.

Standard Specification for Fine-Wire Bunch-Stranded and Rope-Lay Bunch-Stranded Copper Conductors for Use as Electrical Conductors

ICS
29.050 (Superconductivity and conducting materials
CCS
K11
发布
2003
实施

1.1 This specification covers bare bunch-stranded and rope-lay bunch-stranded conductors made from round copper wires finer than No. 40 AWG with diameters less than 0.0031 in. (.078 mm), either coated or uncoated with tin or silver, for use as electrical conductors. (Explanatory Note 1). 1.2 The values (SI units) for density and temperature are regarded as the standard. For all other properties the inch-pound values are to be regarded as standard, and the SI units may be approximate.

Standard Specification for Fine-Wire Bunch-Stranded and Rope-Lay Bunch-Stranded Copper Conductors for Use as Electrical Conductors

ICS
29.050 (Superconductivity and conducting materials
CCS
K11
发布
2003
实施

1.1 This specification covers shaped wire compact concentric-lay-stranded aluminum conductor, steel-reinforced (ACSR/TW) and its component wires for use as overhead electrical conductors (Explanatory Note 1 and 2).1.2 The values stated in inch-pound units are to be regarded as the standard with the exception of temperature, density, and resistivity. The SI equivalents of inch-pound units may be approximate.Note 18212;ACSR/TW is designed to increase the aluminum area for a given diameter of conductor by the use of trapezoidally shaped wires (TW). The conductors consist of a central core of round steel wire(s) surrounded by two or more layers of trapezoidal aluminum 1350-H19 wires. Different strandings of the same size of conductor are identified by type, which is the approximate ratio of steel area to aluminum area expressed in percent (Table 1, Table 2 and Table3). For the purpose of this specification, the sizes listed in Table1 and Table 2 are tabulated on the basis of the finished conductor having an area or outside diameter equal to that of specific sizes of standard ACSR so as to facilitate conductor selection.Note 28212;The aluminum and temper designations conform to ANSI Standard H 35.1. Aluminum 1350 corresponds to Unified Numbering System (UNS) A91350 in accordance with Practice E 527.

Standard Specification for Shaped Wire Compact Concentric-Lay-Stranded Aluminum Conductors, Steel-Reinforced (ACSR/TW)

ICS
29.240.20 (Power transmission and distribution lin
CCS
K11
发布
2003
实施

1.1 This specification covers round wire concentric-lay-stranded aluminum conductors, steel supported (ACSS) for use as overhead electrical conductors (see Explanatory Note 1).1.2 The values stated in inch-pound or SI units are to be regarded separately as standard. Each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification. For conductor sizes designated by AWG or kcmil sizes, the requirements in SI units are numerically converted from the corresponding requirements in inch-pound units. For conductor sizes designation by AWG or kcmil, the requirements in SI units have been numerically converted from corresponding values stated or derived in inch-pound units. For conductor sizes designated by SI units only, the requirements are stated or derived in SI units.1.2.1 For density, resistivity and temperature, the values stated in SI units are to be regarded as standard.

Standard Specification for Concentric-Lay-Stranded Aluminum Conductors, Coated Steel Supported (ACSS)

ICS
29.060.10 (Wires)
CCS
K11
发布
2003
实施

Specifies the essential mechanical, electrical and optical characteristics, acceptance criteria and test requirements for metallic armoured optical ground wire (OPGW) for application with a nominal voltage from 66 kV up to and including 765 kV.

Specification for overhead ground wire with optical fibre Part 1: Product specification

ICS
29.060
CCS
K11
发布
2002-08-01
实施
2002-08-01

이 규격은 주로 전기 기계 기구의 권선에 사용하는 평각 동선에 대하여 규정한다.

Rectangular copper wires for electrical purposes

ICS
29.060.10
CCS
K11
发布
2002-07-31
实施
2002-07-31

This Standard applies to (a) power supplies including transformer units of both the direct plug—in and cord—connected types that utilize a step—down, isolating transformer of the extra—low—voltage secondary type and that may incorporate rectifiers and

Telecommunications Cables The Third Edition; UL 444; Includes Updates 1-4

ICS
CCS
K11
发布
2002-03-29
实施

This International Standard specifies the electrical and mechanical characteristics of concentric lay, overhead conductors of wires formed or shaped before, during or after stranding, made of combinations of any of the following metal wires: a) hard aluminium as per IEC 60889 designated A1; b) hard aluminium as per IEC 60889 designated A1F wire shaped before stranding; c) hard aluminium alloy as per IEC 60104 designated A2 or A3; d) hard aluminium alloy as per IEC 60104 designated A2F or A3F shaped before stranding; e) regular strength steel, designated S1A or S1B, where A and B are zinc coating classes, corresponding respectively to classes 1 and 2; f) high strength steel, designated S2A or S2B; g) extra high strength steel, designated S3A; h) aluminium clad steel, designated SA. The following are examples of some possible conductor designations. Other combinations are also permitted. • A1F, A2F, A3F • A1F/S1A, A1F/S1B, A1F/S2A, A1F/S2B, A1F/S3A • A1F/A1, A1F/A2, A1F/A3 • A1F/SA, A2F/SA, A3F/SA Other possible conductor types not included above are not specifically excluded.

Overhead electrical conductors - Formed wire, concentric lay, stranded conductors

ICS
29.060.20
CCS
K11
发布
2002-02
实施
2002-03-12

1.1 This specification covers concentric-lay-stranded conductors made from uncoated hard-drawn round copper wires in combination with hard-drawn round copper-clad steel wires, for general use as overhead electrical conductors.1.2 For the purpose of this specification, conductors are classified under the following type designations (see Fig 1): Type AType GType CType JType DType KType EType NType EKType PType FType V1.3 The SI values for density are regarded as the standard. For all other properties the inch-pound values are to be regarded as standard and the SI units may be approximate.

Standard Specification for Concentric-Lay-Stranded Copper and Copper-Clad Steel Composite Conductors

ICS
29.060.20 (Cables)
CCS
K11
发布
2002
实施

1.1 This specification covers uninsulated metallic-coated copper conductors for use in hookup wire for electronic equipment.1.2 The SI values for density are to be regarded as standard. For all other properties, the inch-pound values are to be regarded as the standard.

Standard Specification for Copper Conductors for Use in Hookup Wire for Electronic Equipment

ICS
29.060.10 (Wires)
CCS
K11
发布
2002
实施

1.1 This specification covers bare round copper-clad steel wire for electronic application.1.2 Four classes of copper-clad steel wire are covered as follows:1.2.1 Class 30HS8212;Nominal 30 % conductivity hard-drawn,1.2.2 Class 30A8212;Nominal 30 % conductivity annealed,1.2.3 Class 408212;HSNominal 40 % conductivity hard-drawn, and1.2.4 Class 40ANominal 40 % conductivity annealed.1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are in SI units.

Standard Specification for Copper-Clad Steel Wire for Electronic Application

ICS
29.060.10 (Wires)
CCS
K11
发布
2002
实施

1.1 This specification prescribes standard nominal diameters and cross-sectional areas of American Wire Gage (AWG) sizes of solid round wires, used as electrical conductors, and gives equations and rules for the calculation of standard nominal mass and lengths, resistances, and breaking strengths of such wires (Explanatory Note 1). 1.2 The values stated in inch-pound or SI units are to be regarded separately as standard. Each system shall be used independently of the other. Combining values of the two systems may result in nonconformance with the specification. For conductor sizes designated by AWG or kcmil sizes, the requirements in SI units have been numerically converted from the corresponding values stated or derived, in inch-pound units. For conductor sizes designated by SI units only, the requirements are stated or derived in SI units. 1.2.1 For density, resistivity and temperature, the values stated in SI units are to be regarded as standard.

Standard Specification for Standard Nominal Diameters and Cross-Sectional Areas of AWG Sizes of Solid Round Wires Used as Electrical Conductors

ICS
29.060.10 (Wires)
CCS
K11
发布
2002
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved