K11 裸电线 标准查询与下载



共找到 506 条与 裸电线 相关的标准,共 34

1.1 This specification covers aluminum-alloy 6201-T81 (hard: solution heat-treated, cold worked, and artificially aged) round wire for electrical purposes.Note 1 - The alloy and temper designations conform to ANSI H35.1 and H35.1M. Aluminum-alloy 6201 corresponds to unified numbering system alloy A96201 in accordance with Practice E 527.1.2 The values stated in inch-pound or SI units are to be regarded separately as standard. The values in each system are not exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification.1.2.1 For density, resistivity and temperature, the values stated in SI units are to be regarded as standard.

Standard Specification for Aluminum-Alloy 6201-T81 Wire for Electrical Purposes

ICS
29.060.10 (Wires)
CCS
K11
发布
2002
实施

1.1 This specification covers stranded uninsulated bare, tin, or tin-lead alloy coated copper conductors in which wires in the strand are metallically bonded together by the application of heat or additional tin, or tin-lead alloy for use in hookup wire for electronic equipment. 1.2 The SI values for density and resistivity are to be regarded as standard. For all other properties, the inch-pound values are to be regarded as the standard and the SI units may be approximate. 1.3 The hazard caveat pertains only to Section 6 of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Bonded Copper Conductors for Use in Hookup Wires for Electronic Equipment

ICS
29.060.10
CCS
K11
发布
2002
实施

1.1 This specification covers shaped wire compact concentric-lay-stranded aluminum conductors, steel supported (ACSS/TW) for use as overhead electrical conductors (see Explanatory Note 1). 1.2 The values stated in inch-pound or SI units are to be regarded separately as standard. Each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the specification. For conductor sizes designated by AWG or kcmil sizes, the requirements in SI units are numerically converted from the corresponding requirements in inch-pound units. For conductor sizes designation by AWG or kcmil, the requirements in SI units have been numerically converted from corresponding values stated or derived in inch-pound units. For conductor sizes designated by SI units only, the requirements are stated or derived in SI units.1.2.1 For density, resistivity, and temperature, the values stated in SI units are to be regarded as standard.1.3 ACSS/TW is designed to increase the aluminum area for a given diameter of conductor by the use of trapezoidal shaped wires (TW). The conductors consist of a central core of round steel wire(s) surrounded by two or more layers of trapezoidal aluminum 1350-0 wires. Different strandings of the same size of conductor are identified by type, which is the approximate ratio of steel area to aluminum area expressed in percent (see Table 1, Table 2, and Table 3 ). For the purpose of this specification, the sizes listed in Table 1 and Table 2 are tabulated on the basis of the finished conductor having an area or outside diameter equal to that of specified sizes of standard ACSR, ACSS, and ACSR/TW so as to facilitate conductor selection.

Standard Specification for Shaped Wire Compact Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Supported (ACSS/TW)

ICS
29.060.10 (Wires)
CCS
K11
发布
2002
实施

1.1 This specification covers shaped wire compact concentric-lay-stranded aluminum conductor (AAC/TW) and its component wires for use as overhead electrical conductors (Explanatory Note 1 and Note 2).1.2 The values stated in inch-pound units are to be regarded as the standard with the exception of temperature and resistivity. The SI equivalents of inch-pound units may be approximate. Note 1 - AAC/TW is designed to increase the aluminum area for a given diameter of conductor by the use of trapezoidally shaped wires (TW). The conductors consist of a central core of one round aluminum wire or a seven-strand compact round core surrounded by two or more layers of trapezoidal aluminum 1350-H19 wires. For the purposes of this specification, the sizes listed are tabulated on the basis of the finished conductor having an area equal to that of specific sizes of standard AAC (Table 1) or in fixed diameter increments (Table 2) so as to facilitate conductor selection.Note 2The aluminum and temper designations conform to ANSI Standard H 35.1. Aluminum 1350 corresponds to Unified Numbering System (UNS) A91350 in accordance with Practice E 527.

Standard Specification for Shaped Wire Compact Concentric-Lay-Stranded Aluminum Conductors (AAC/TW)

ICS
29.240.20 (Power transmission and distribution lin
CCS
K11
发布
2002
实施

1.1 This specification covers aluminum-alloy 6201-T81 (hard: solution heat-treated, cold worked, and artificially aged) round wire for electrical purposes.Note 18212;The alloy and temper designations conform to ANSI H35.1 and H35.1M. Aluminum-alloy 6201 corresponds to unified numbering system alloy A96201 in accordance with Practice E 527.1.2 The values stated in inch-pound or SI units are to be regarded separately as standard. The values in each system are not exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification.1.2.1 For density, resistivity and temperature, the values stated in SI units are to be regarded as standard.

Standard Specification for Aluminum-Alloy 6201-T81 Wire for Electrical Purposes

ICS
29.060.10 (Wires)
CCS
K11
发布
2002
实施

1.1 This specification covers stranded uninsulated bare, tin, or tin-lead alloy coated copper conductors in which wires in the strand are metallically bonded together by the application of heat or additional tin, or tin-lead alloy for use in hookup wire for electronic equipment. 1.2 The SI values for density and resistivity are to be regarded as standard. For all other properties, the inch-pound values are to be regarded as the standard and the SI units may be approximate. 1.3 8199;The hazard caveat pertains only to Section 6 of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Bonded Copper Conductors for Use in Hookup Wires for Electronic Equipment

ICS
29.060.10 (Wires)
CCS
K11
发布
2002
实施

1.1 This specification covers stranded uninsulated bare, tin, or tin-lead alloy coated copper conductors in which wires in the strand are metallically bonded together by the application of heat or additional tin, or tin-lead alloy for use in hookup wire for electronic equipment.1.2 The SI values for density and resistivity are to be regarded as standard. For all other properties, the inch-pound values are to be regarded as the standard and the SI units may be approximate.1.3 The hazard caveat pertains only to Section 6 of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Bonded Copper Conductors for Use in Hookup Wires for Electronic Equipment

ICS
29.060.10 (Wires)
CCS
K11
发布
2002
实施

1.1 This specification covers shaped wire compact concentric-lay-stranded aluminum conductor (AAC/TW) and its component wires for use as overhead electrical conductors (Explanatory Note 1 and Note 2). 1.2 The values stated in inch-pound units are to be regarded as the standard with the exception of temperature and resistivity. The SI equivalents of inch-pound units may be approximate. Note 1???AAC/TW is designed to increase the aluminum area for a given diameter of conductor by the use of trapezoidally shaped wires (TW). The conductors consist of a central core of one round aluminum wire or a seven-strand compact round core surrounded by two or more layers of trapezoidal aluminum 1350-H19 wires. For the purposes of this specification, the sizes listed are tabulated on the basis of the finished conductor having an area equal to that of specific sizes of standard AAC (Table 1) or in fixed diameter increments (Table 2) so as to facilitate conductor selection.TABLE 1 Construction Requirements for Shaped Wire Compact Concentric-Lay-Stranded Aluminum Conductors Sized to Have Areas Equal to AAC Size Code WordA AAC/TW Conductor size Nominal Outside Diameter Number of Aluminum Wires Number of Layers Nominal Mass Rated Strength

Standard Specification for Shaped Wire Compact Concentric-Lay-Stranded Aluminum Conductors (AAC/TW)

ICS
29.240.20 (Power transmission and distribution lin
CCS
K11
发布
2002
实施

1.1 This specification covers stranded uninsulated bare, tin, or tin-lead alloy coated copper conductors in which wires in the strand are metallically bonded together by the application of heat or additional tin, or tin-lead alloy for use in hookup wire for electronic equipment.1.2 The SI values for density and resistivity are to be regarded as standard. For all other properties, the inch-pound values are to be regarded as the standard and the SI units may be approximate.1.3 The hazard caveat pertains only to Section 6 of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Bonded Copper Conductors for Use in Hookup Wires for Electronic Equipment

ICS
29.060.10 (Wires)
CCS
K11
发布
2002
实施

1.1 This specification covers bare concentric-lay-stranded conductors made from bare round copper-clad steel wires for general use for electrical purposes. 1.2 For the purpose of this specification, conductors are classified as follows: Grade 40 HS, Grade 30 HS, and Grade 30 EHS. 1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.

Standard Specification for Concentric-Lay-Stranded Copper-Clad Steel Conductors

ICS
29.060.20 (Cables)
CCS
K11
发布
2002
实施

1.1 This specification prescribes standard nominal diameters and cross-sectional areas of American Wire Gage (AWG) sizes of solid round wires, used as electrical conductors, and gives equations and rules for the calculation of standard nominal mass and lengths, resistances, and breaking strengths of such wires (Explanatory Note 1).1.2 The values stated in inch-pound or SI units are to be regarded separately as standard. Each system shall be used independently of the other. Combining values of the two systems may result in nonconformance with the specification. For conductor sizes designated by AWG or kcmil sizes, the requirements in SI units have been numerically converted from the corresponding values stated or derived, in inch-pound units. For conductor sizes designated by SI units only, the requirements are stated or derived in SI units.1.2.1 For density, resistivity and temperature, the values stated in SI units are to be regarded as standard.

Standard Specification for Standard Nominal Diameters and Cross-Sectional Areas of AWG Sizes of Solid Round Wires Used as Electrical Conductors

ICS
29.060.10
CCS
K11
发布
2002
实施

1.1 This specification covers shaped wire compact concentric-lay-stranded aluminum conductor (AAC/TW) and its component wires for use as overhead electrical conductors (Explanatory Note 1 and Note 2).1.2 The values stated in inch-pound units are to be regarded as the standard with the exception of temperature and resistivity. The SI equivalents of inch-pound units may be approximate. Note 18212;AAC/TW is designed to increase the aluminum area for a given diameter of conductor by the use of trapezoidally shaped wires (TW). The conductors consist of a central core of one round aluminum wire or a seven-strand compact round core surrounded by two or more layers of trapezoidal aluminum 1350-H19 wires. For the purposes of this specification, the sizes listed are tabulated on the basis of the finished conductor having an area equal to that of specific sizes of standard AAC (Table 1) or in fixed diameter increments (Table 2) so as to facilitate conductor selection.Note 28212;The aluminum and temper designations conform to ANSI Standard H 35.1. Aluminum 1350 corresponds to Unified Numbering System (UNS) A91350 in accordance with Practice E 527.

Standard Specification for Shaped Wire Compact Concentric-Lay-Stranded Aluminum Conductors (AAC/TW)

ICS
29.240.20 (Power transmission and distribution lin
CCS
K11
发布
2002
实施

Conductors for overhead lines - Round wire concentric lay stranded conductors.

ICS
29.060.10
CCS
K11
发布
2001-12-01
实施
2001-12-20

This European Standard specifies the electrical and mechanical characteristics of round wire concentric lay bare overhead electrical conductors stranded in alternate directions, with or without grease as per EN 50326, made of one or a combination of any of the following: a) Hard drawn Aluminium as per EN 60889 designated AL1 b) Aluminium alloy as per EN 50183 designated AL2 to AL7 c) Zinc coated steel wire as per EN 50189 with grade and class designated ST1A, ST2B, ST3D, ST4A, ST5E, and ST6C. d) Aluminium-clad steel wire as per EN 61232 with class designation 20SA (grades A and B), 27SA, 30SA and 40SA. Conductors made of zinc coated steel wires only are not included.

Conductors for overhead lines — Round wire concentric lay stranded conductors Incorporating Corrigenda Nos. 1 and 2

ICS
29.060.10
CCS
K11
发布
2001-08-15
实施

Conductors for overhead lines - Zinc coated steel wires.

ICS
29.060.10
CCS
K11
发布
2001-01-01
实施
2001-01-20

1.1 This specification covers bare modified concentric-lay-stranded conductors made from round copper wires, either uncoated or coated with tin, lead, or lead alloy for general use in insulated electrical cables. These conductors shall be constructed with a central core consisting of not more than seven wires, surrounded by one or more layers of helically laid wires.1.2 For the purposes of this specification, conductors are classified as follows (Explanatory Note 1 and Note 2):1.2.1 Class B Modified8212;Conductors to be insulated with various materials such as rubber, paper, and crosslink polyethylene.1.2.2 Class C Modified and Class D Modified8212;Conductors where greater flexibility is required than is provided by Class B Modified conductors.1.3 The values stated in inch-pound or SI units are to be regarded separately as standard. Each system shall be used independently of the other. Combining the values from the two systems may result in non- conformance with the specification. For conductor sizes designated by AWG or kcmil sizes, the requirements in SI units are numerically converted from the corresponding requirements in inch-pound units. For conductor sizes designated by AWG or kcmil, the requirements in SI units have been numerically converted from corresponding values stated or derived in inch-pound units. for conductor sizes designated by SI units only, the requirements are stated or derived in SI units.1.3.1 For density, resitivity and temperature, the values stated in SI units are to be regarded as standard.Note 18212;The significant differences in this specification from Specification B 8 are as follows: (1) The central core is permitted to contain up to seven wires drawn into the assembly with an infinite length of lay while Specification B 8 permits only one, and (2) The construction is applicable only to stranded assemblies of 19 or more wires.

Standard Specification for Modified Concentric-Lay-Stranded Copper Conductors for Use in Insulated Electrical Cables

ICS
29.060.20 (Cables)
CCS
K11
发布
2001
实施

1.1 This specification covers bare rope-lay-stranded conductors having concentric-stranded members made from round copper wires, either uncoated or coated with tin, lead, or lead-alloy for use as electrical conductors (Explanatory Note 1 and Note 2).1.2 Coated wires shall include only those wires with finished diameters and densities substantially equal to the respective diameters and densities of uncoated wires.1.3 The values stated in inch-pound or SI units are to be regarded separately as standard. Each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification. For conductor sizes designated by AWG or kcmil, the requirements in SI units have been numerically converted from corresponding values, stated or derived, in inch-pound units. For conductor sizes designated by SI units only, the requirements are stated or derived in SI units.1.3.1 For density, resistivity, and temperature, the values stated in SI units are to be regarded as standard.

Standard Specification for Rope-Lay-Stranded Copper Conductors Having Concentric-Stranded Members, for Electrical Conductors

ICS
29.240.20 (Power transmission and distribution lin
CCS
K11
发布
2001
实施

1.1 This specification covers aluminum 1350-O, annealed, 1350-H12 or -H22 (1/4 hard), 1350-H14 or -H24 (1/2 hard), 1350-H16 or -H26 (3/4 hard), and 1350-H19 (extra hard) wire, rectangular or square in shape with rounded corners for use as electrical conductors in insulated magnet wire.1.2 The values stated in inch-pound or SI units are to be regarded separately as standard. Each system shall be used independently of the other. Combining the values from the two systems may result in non-conformance with the specification. For conductor sizes designated by AWG or kcmil sizes, the requirements in SI units are numerically converted from the corresponding requirements in inch-pound units. For conductor sizes designated by AWG or kcmil, the requirements in SI units have been numerically converted from corresponding values stated or derived in inch-pound units. for conductor sizes designated by SI units only, the requirements are stated or derived in SI units.1.2.1 For density, resitivity and temperature, the values stated in SI units are to be regarded as standard.Note 18212;The aluminum and temper designations conform to ANSI H35.1. Aluminum 1350 corresponds to Unified Numbering System A91350 in accordance with Practice E 527.

Standard Specification for Aluminum Rectangular and Square Wire for Electrical Purposes

ICS
29.060.10 (Wires)
CCS
K11
发布
2001
实施

1.1 This specification prescribes standard nominal diameters and cross-sectional areas of American Wire Gage (AWG) sizes of solid round wires, used as electrical conductors, and gives equations and rules for the calculation of standard nominal mass and lengths, resistances, and breaking strengths of such wires (Explanatory Note 1).1.2 The values stated in inch-pound or SI units are to be regarded separately as standard. Each system shall be used independently of the other. Combining values of the two systems may result in nonconformance with the specification. For conductor sizes designated by AWG or kcmil sizes, the requirements in SI units have been numerically converted from the corresponding values stated or derived, in inch-pound units. For conductor sizes designated by SI units only, the requirements are stated or derived in SI units.1.2.1 For density, resistivity and temperature, the values stated in SI units are to be regarded as standard.

Standard Specification for Standard Nominal Diameters and Cross-Sectional Areas of AWG Sizes of Solid Round Wires Used as Electrical Conductors

ICS
29.060.10 (Wires)
CCS
K11
发布
2001
实施

1.1 This specification covers hard-drawn round copper wire for electrical purposes.1.2 The values stated in inch-pound or SI units are to be regarded separately as standard. Each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the specification. For conductor sizes designated by AWG or kcmil sizes, the requirements in SI units are numerically converted from the corresponding requirements in inch-pound units. For conductor sizes designation by AWG or kcmil, the requirements in SI units have been numerically converted from corresponding values stated or derived in inch-pound units. For conductor sizes designated by SI units only, the requirements are stated or derived in SI units.1.2.1 For density, resistivity and temperature, the values stated in SI units are to be regarded as standard.

Standard Specification for Hard-Drawn Copper Wire

ICS
29.060.10
CCS
K11
发布
2001
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号