共找到 187 条与 控制继电器 相关的标准,共 13 页
The standard deals with the sectional specification for electro-mechanical all-or-nothing relays of assessed quality.
Sectional specification: electromechanical all-or-nothing relays (including relays for severe environmental conditions); german version EN 116200:1991
Blank detail specification: electromechanical all-or-nothing telecom relays of assessed quality, dual-in-line, with 14
Sectional specification: electromechanical all-or-nothing relays (including relays for severe environmental conditions)
Sectional specification; electromechanical all-or-nothing telecom relays of assessed quality
Blank detail specification; electromechanical all-or-nothing telecom relays of assessed quality
Blank detail specification; electromechanical all-or-nothing telecom relays of assessed quality, dual-in-line, with 20
Guide for Protective Relay Applications to Power System Buses
Prezentul standard se refer? la placajul alc?tuit din straturi de furnire tehnice din lemn de fag, destinat pentru lucr?ri de interior (tip de ?ncleiere J20 conform STAS 8518-86), ?ncleiate cu r??ini ureoformaldehidice.
Beech veneer plywood for inner works
VMlVVt vJ? W4HV1*1 U UV UL/AAV'U.kV' Prezentul standard se refer? la placajul din furnire tehnice de fag, ?ncleiate conform tipului de ?ncleiere J10o (STAS 8318-86), destinat pentru construc?ia pere?ilor vagoanelor de marf? acoper
Beechwood veneer for covered freight cars
Guide for differential and polarizing relay circuit testing
Surge withstand capability (SWC) tests for protective relays and relay systems
Includes two types of test: the shock test (on energized and non-energized specimen), the bump test (on non-energized specimen) and is generally based upon IEC 68-2-27 and 68-2-29. The tests specified are type tests. States: definitions of terms used (in
Electrical relays; part 21: vibration, shock, bump and seismic tests on measuring relays and protection equipment; section two: shock and bump tests
Describes the basic principles, requirements, and methods for qualifying Class 1E protective relays and auxiliaries such as test and control switches, terminal blocks, and indicating lamps for applications in nuclear power generating stations.
Qualifying class 1E protective relays and auxiliairies for nuclear power generating stations
Guide for protective relay application to power transformers
Specifies the basic dimensional modules to be used in determining the external dimensions of general purpose all-or-nothing relays and the locations of their terminal and fixing centres.
Electrical relays - Specification for the basic modules for the dimensions of general purpose all-or-nothing relays
Electrical relays. Part 20 : Protection (protective) systems.
Specifies characteristics of standard types of contact load to be used in endurance tests of electrical relay contacts over ranges of voltages and currents corresponding to defined application categories. Also lists preferred values for contact loads.
Electrical relays. Specification for contact loads of preferred values used in endurance tests for electrical relay contacts
Specifies environmental conditions for operation, parameters of associated relay input and output circuits, and control and failure indication requirements. Lists relevant terminology.
Electrical relays. Specification for test equipment used in endurance tests for electrical relay contacts
This recommendation is applicable to contact assemblies of relays within the scope of the IEC. It covers basic considerations which are, in general, common to all types of relays covered by IEC Publication 255, Electrical Relays, but supplementary requirements may be necessitated by specific designs or application. It applies only to relays in a new condition.