K60 电气设备与器具综合 标准查询与下载



共找到 331 条与 电气设备与器具综合 相关的标准,共 23

This standard is about Electrical equipment for measurement, control and laboratory use, control and laboratory use - EMC requirements - Part 1: General requirements; Corrigendum 1

Electrical equipment for measurement, control and laboratory use, control and laboratory use - EMC requirements - Part 1: General requirements; Corrigendum 1

ICS
33.100.01
CCS
K60
发布
2008-02
实施
2008-02-29

The scope of IEC 61326-1 applies to this part of IEC 61326 but is limited to systems and equipment for industrial applications intended to perform safety functions as defined in IEC 61508 with SIL 1-3. The electromagnetic environments encompassed by this product family standard are industrial, both indoor and outdoor, as described for industrial locations in IEC 61000-6-2 or defined in 3.7 of IEC 61326-1. Equipment and systems intended for use in other electromagnetic environments, for example, in the process industry or in environments with potentially explosive atmospheres, are excluded from the scope of this product family standard, IEC 61326-3-1. Equipment and systems considered as “proven-in-use” according to IEC 61508 or IEC 61511 are excluded from the scope of IEC 61326-3-1. Fire alarm systems and security alarm systems intended for protection of buildings are excluded from the scope of IEC 61326-3-1.

Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-1: Immunity requirements for safety-related systems and for equipment intended to perform safety related functions (functional safety) - General industrial applic

ICS
25.040.40;33.100.20
CCS
K60
发布
2008-01
实施
2017-05-18

The scope of IEC 61326-1 applies to this part of IEC 61326 but is limited to systems and equipment for industrial applications within a specified electromagnetic environment and intended to perform safety functions as defined in IEC 61508 with SIL 1-3. The electromagnetic environments encompassed by this product family standard are industrial, both indoor and outdoor, as they can be found in industrial applications with an electromagnetic environment having specified characteristics (for example, process industry). The difference between the electromagnetic environment covered by this standard compared to the general industrial environment (see IEC 61326-3-1) is due to the mitigation measures employed against electromagnetic phenomena leading to a specified electromagnetic environment. The environment of industrial application with a specified electromagnetic environment typically includes the following characteristics: – industrial area with limited access; – limited use of mobile transmitter; – dedicated cables for power supply and control, signal or communication lines; – separation between power supply and control, signal or communication cables; – factory building mostly consisting of metal construction; – overvoltage/lightning protection by appropriate measures (for example, metal construction of the building or use of protection devices); – pipe heating systems driven by a.c. main power may be present; – no high-voltage substation close to sensitive areas; – presence of CISPR 11 Group 2 ISM equipment using ISM frequencies only with low power; – competent staff; – periodical maintenance of equipment and systems; – mounting and installation guidelines for equipment and systems. A more detailed description of the above-mentioned typical characteristics is given in Annex B. Equipment and systems considered as “proven-in-use” according to IEC 61508 or IEC 61511 are excluded from the scope of IEC 61326-3-2. Fire alarm systems and security alarm systems intended for protection of buildings are excluded from the scope of IEC 61326-3-2.

Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-2: Immunity requirements for safety-related systems and for equipment intended to perform safety related functions (functional safety) - Industrial applications w

ICS
25.040.40;33.100.20
CCS
K60
发布
2008-01
实施
2017-05-18

This Part of IEC 61968 specifies the information content of a set of message types that can be used to support many of the business functions related to records and asset management. Typical uses of the message types defined in this Part of IEC 61968 include network extension planning, copying feeder or other network data between systems, network or diagram edits and asset inspection. Message types defined in other Parts of IEC 61968 may also be relevant to these use cases.

Application integration at electric utilities - System interfaces for distribution management - Part 4: Interfaces for records and asset management (IEC 61968-4:2007); German version EN 61968-4:2007, text in English

ICS
35.200
CCS
K60
发布
2007-12
实施
2007-12-01

This standard is about Electrical equipment for measurement, control and laboratory use, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable test, measuring and monitoring equipment used in low-voltage distribution systems; Corrigendum 1

Electrical equipment for measurement, control and laboratory use, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable test, measuring and mon

ICS
33.100.01
CCS
K60
发布
2007-11
实施
2007-11-16

이 규격은 몸체의 내부에 전열 장치를 갖는 것으로 단상 교류 300 V 이하의 감열선식 전

Electrically heated over-blankets and under-blankets

ICS
97.17
CCS
K60
发布
2007-09-28
实施
2007-09-28

Reaffirmation of the Fourth Edition of the Standard for Isolated Power Systems Equipment, UL 1047, as an American National Standard.

UL Standard for Safety Isolated Power Systems Equipment ALL COMMENTS DUE: October 29, 2007

ICS
29.160.40
CCS
K60
发布
2007-09-14
实施

This standard is about Safety of machinery - Electro-sensitive protective equipment - Part 1: General requirements and tests; Amendment 1

Safety of machinery - Electro-sensitive protective equipment - Part 1: General requirements and tests; Amendment 1

ICS
13.110;29.260.99
CCS
K60
发布
2007-09
实施
2007-09-26

This standard is about Electrical equipment for measurement, control and laboratory use, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In-vitro diagnostic (IVD) medical equipment; Corrigendum 1

Electrical equipment for measurement, control and laboratory use, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In-vitro diagnostic (IVD) medical equipment; Corrigendum 1

ICS
33.100.01
CCS
K60
发布
2007-09
实施

1.1.1 Equipment included in scope Addition: At the end of the subclause, add the following new paragraph and two notes: This Part applies to any of the above equipment that is RATED for use by persons under the age of 18 years in educational establishments and under the supervision of a competent person. The equipment might not necessarily be used in a formal laboratory. NOTE 1 In this context, laboratory equipment does not include equipment for forming or machining resistant materials. NOTE 2 If all or part of the equipment falls within the scope of one or more Part 2 standards of BS EN 61010 as well as within the scope of this Draft for Development, it will also need to meet the requirements of those Part 2 standards. 1.2.1 Aspects included in scope Addition: Add the following new note, and renumber the existing note as note 1: NOTE 2 Attention is also drawn to the existence of additional requirements that can be specified by national authorities responsible for the health and safety of persons in education with special needs.

Safety requirements for electrical equipment for measurement, control and laboratory use - Particular requirements for equipment rated for use by children and young people in educational establishments

ICS
19.080;71.040.10
CCS
K60
发布
2007-07-31
实施
2007-07-31

1.1.1 Equipment included in scope Addition: At the end of the subclause, add the following new paragraph and two notes: This Part applies to any of the above equipment that is RATED for use by persons under the age of 18 years in educational establishments and under the supervision of a competent person. The equipment might not necessarily be used in a formal laboratory. NOTE 1 In this context, laboratory equipment does not include equipment for forming or machining resistant materials. NOTE 2 If all or part of the equipment falls within the scope of one or more Part 2 standards of BS EN 61010 as well as within the scope of this Draft for Development, it will also need to meet the requirements of those Part 2 standards. 1.2.1 Aspects included in scope Addition: Add the following new note, and renumber the existing note as note 1: NOTE 2 Attention is also drawn to the existence of additional requirements that can be specified by national authorities responsible for the health and safety of persons in education with special needs.

Safety requirements for electrical equipment for measurement, control and laboratory use. Particular requirements for equipment rated for use by children and young people in educational establishments

ICS
19.080;71.040.10
CCS
K60
发布
2007-07-31
实施
2007-07-31

Applicable to electrically powered laboratory centrifuges.

Safety requirements for electrical equipment for measurement, control and laboratory use Part 2-020: Particular requirements for laboratory centrifuges

ICS
19.080;71.040.20
CCS
K60
发布
2007-06-22
实施

Applies to electrically powered laboratory equipment for the heating of materials, where the heating of materials is the only function or is one of several functions of the equipment.

Safety requirements for electrical equipment for measurement, control and laboratory use Part 2-010: Particular requirements for laboratory equipment for the heating of materials

ICS
19.080;71.040.20
CCS
K60
发布
2007-06-22
实施

Low-voltage electrical installations - Part 5-51: Selection and erection of electrical equipment - Common rules (IEC 60364-5-51:2001, modified); German implementation HD 60364-5-51:2006

ICS
29.240.01;91.140.50
CCS
K60
发布
2007-06
实施
2007-06-01

This International Standard specifies oil-sampling procedures, analysis requirements and procedures, and recommends sensitivity, repeatability and accuracy criteria for the application of dissolved gas analysis (DGA) to factory testing of new power transformers, reactors and instrument transformers filled with mineral insulating oil when DGA testing has been specified. The most effective and useful application of DGA techniques to factory testing is during the performance of long-term tests, typically temperature-rise (heat run) and overloading tests on power transformers and reactors, also impulse tests on instrument transformers. DGA may also be valuable for over-excitation tests run over an extended period of time. Experience with DGA results, before and after short-time dielectric tests, indicates that DGA is normally less sensitive than electrical and acoustic methods for detecting partial discharges. However, DGA will indicate when these partial discharges become harmful to the insulation and may be detected by inspection [2].

Mineral oil-filled electrical equipment - Application of dissolved gas analysis (DGA) to factory tests on electrical equipment

ICS
29.040.10
CCS
K60
发布
2007-05-31
实施
2007-05-31

Mineral oil-filled electrical equipment. Application of dissolved gas analysis (DGA) to factory tests on electrical equipment

ICS
29.040.10
CCS
K60
发布
2007-05-31
实施
2007-05-31

Specifies the framework for describing demand response capabilities and supporting technologies for electrical products that offer scope for reduction in energy use and hence power consumption at times of peak demand or other stresses on the electricity

Framework for demand response capabilities and supporting technologies for electrical products

ICS
29.020;97.030
CCS
K60
发布
2007-05-15
实施

This standard covers non-walk-in heating ovens and incubators suitable for a working temperature range of -10 ℃ to 300 ℃. Incubators also include shaking incubators. The standard gives terms and definitions and specifies performance requirements and tests. Controlled-atmosphere test installations (e.g. as in DIN 50011) and hot air sterilizers are not covered by this standard.

Electrical laboratory devices - Heating ovens and incubators

ICS
71.040.10
CCS
K60
发布
2007-05
实施

Specifications for industrial laundry machines - Definitions and testing of capacity and consumption characteristics - Part 4 : washer-extractors.

ICS
97.060
CCS
K60
发布
2007-04-01
实施
2007-04-05

Specifications for industrial laundry machines - Definitions and testing of capacity and consumption characteristics - Part 3 : washing tunnels.

ICS
97.060
CCS
K60
发布
2007-04-01
实施
2007-04-05



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved