共找到 186 条与 定型隔热耐火材料 相关的标准,共 13 页
Method for acceptance of samples of refractory products for glass melting kilns
Classifies on the basis of physical and chemical properties.
Classification of refractories - Ceramic fibre products - Blankets, mats, felts and paper
1.1 This specification covers one type of thermal insulating brick for use as backup insulation for refractory furnace linings of boiler furnaces.1.2 The values stated in inch-pound units are to be regarded as standard. The SI units in parentheses are for information purposes only and may be approximate.
Standard Specification for Brick, Insulating, High Temperature, Fire Clay
1.1 This specification covers one type of thermal insulating brick for use as backup insulation for refractory furnace linings of boiler furnaces.1.2 The values stated in inch-pound units are to be regarded as standard. The SI units in parentheses are for information purposes only and may be approximate.
Standard Specification for Brick, Insulating, High Temperature, Fire Clay
Refractory products - Dense,insulating shaped products - Determination of ultrasonic propagation vetocity in transmission
Refractory products - Dense,insulating shaped products - Determination of ultrasonic propagation vetocity in transmission
Refractory products - Dense,insulating shaped products - Determination of the resonance frequency through mechanical impacting
Refractory products - Dense,insulating shaped products - Determination of the resonance frequency through mechanical impacting
3.1 The thermal conductivity of insulating firebrick (IFB) is a property required for the selection of IFB for a specific thermal performance. Users select brick to provide a specified heat-loss and cold-face temperature without exceeding the temperature limitation of the brick. This test method establishes placement of thermocouples and the positioning of test samples in the calorimeter. This test method must be used with Test Method C201. 1.1 This test method supplements Test Method C201, and shall be used in conjunction with that test method to determine the thermal conductivity of insulating firebrick. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Standard Test Method for Thermal Conductivity of Insulating Firebrick
The thermal conductivity of insulating firebrick (IFB) is a property required for the selection of IFB for a specific thermal performance. Users select brick to provide a specified heat-loss and cold-face temperature without exceeding the temperature limitation of the brick. This test method establishes placement of thermocouples and the positioning of test samples in the calorimeter. This test method must be used with Test Method C 201. 1.1 This test method supplements Test Method C 201, and shall be used in conjunction with that test method to determine the thermal conductivity of insulating firebrick. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Standard Test Method for Thermal Conductivity of Insulating Firebrick
The thermal conductivity of insulating firebrick (IFB) is a property required for the selection of IFB for a specific thermal performance. Users select brick to provide a specified heat-loss and cold-face temperature without exceeding the temperature limitation of the brick. This test method establishes placement of thermocouples and the positioning of test samples in the calorimeter. This test method must be used with Test Method C 201. 1.1 This test method supplements Test Method C201, and shall be used in conjunction with that test method to determine the thermal conductivity of insulating firebrick. 1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are provided for information only. 1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Standard Test Method for Thermal Conductivity of Insulating Firebrick
Lightweight and refractory ceramsite concrete block for cement kiln lining
Dimensions of refractory bricks for use in the construction of ladles used during the manufacture of iron and steel.
Sizes of refractory bricks - Specification for bricks for ladles
All types of refractory products used in this application. Tolerances on dimensions are also given, along with design information and recommended ratios for 2-taper lining.
Sizes of refractory bricks - Specification for bricks for rotary cement kilns
Shapes and sizes of refractory bricks that are used in a wide range of industrial applications in high temperature manufacturing processes.
Sizes of refractory bricks - Specification for multi-purpose bricks
This Part of BS 3056 specifies the sizes of the following shapes of refractory bricks for glass-melting furnaces: (a) squares; (b) splits; (c) tiles; (d) blocks; (e) straights; (f) side arch bricks; (g) end arch bricks; (h) crown bricks. NOTE 1. Information is also given on the combinations of size and material/quality that may be expected to be available, on arch-brick formulae (see appendix A), on the combinations of sizes required to form circles of various diameters (see appendix B), and on informa-tion to be supplied by a purchaser (see appendix C). The volume of each standard size brick is given as supplementary information, in tables 1 to 8. NOTE 2. The tolerances on the sizes are not specified in this Part of BS 3056, and may be the subject of agreement between manufacturer and purchaser. NOTE 3. The titles of the publications referred to in this standard are listed on the inside back cover.
Sizes of refractory bricks - Specification for bricks for use in glass-melting furnaces
Specifies the dimensions of refractory bricks for use in the construction of the roofs of electric arc furnaces.
この規格は,耐火断熱れんがの次の各項の試験方法について規定する。
Testing method for specific gravity and true porosity of insulating fire bricks
Briques réfractaires - Dimensions - Partie 6 : Briques basiques pour convertisseurs à oxygène (Première édition)
Refractories - Classification of shaped insulating products.
Refractories - Classification of shaped insulating products.
Refractories - Classification of dense shaped anti-acid products.
Refractories - Classification of dense shaped anti-acid products.
Details the methods for measuring refractory bricks and blocks, and for determining their errors of shape, for use when circumstances do not warrant the use of more elaborate methods.
Methods of testing refractory materials - General and textural properties - Measurement of dimensions and shape of refractory bricks and blocks (methods 1902-311)