Q70 建筑构配件与设备综合 标准查询与下载



共找到 783 条与 建筑构配件与设备综合 相关的标准,共 53

This document specifies methods for the calculation of the thermal transmittance of windows and pedestrian doors consisting of glazed and/or opaque panels fitted in a frame, with and without shutters. This document allows for — different types of glazing (glass or plastic; single or multiple glazing; with or without low emissivity coatings, and with spaces filled with air or other gases), — opaque panels within the window or door, — various types of frames (wood, plastic, metallic with and without thermal barrier, metallic with pinpoint metallic connections or any combination of materials), and — where appropriate, the additional thermal resistance introduced by different types of closed shutter or external blind, depending on their air permeability. The thermal transmittance of roof windows and other projecting windows can be calculated according to this document, provided that the thermal transmittance of their frame sections is determined by measurement or by numerical calculation. Default values for glazing, frames and shutters are given in the annexes. Thermal bridge effects at the rebate or joint between the window or door frame and the rest of the building envelope are excluded from the calculation. The calculation does not include — effects of solar radiation (see standards under M2-8), — heat transfer caused by air leakage (see standards under M2-6), — calculation of condensation, — ventilation of air spaces in double and coupled windows, and — surrounding parts of an oriel window. The document is not applicable to — curtain walls and other structural glazing (see other standards under M2-5), and — industrial, commercial and garage doors. NOTE Table 1 in the Introduction shows the relative position of this document within the set of EPB standards in the context of the modular structure as set out in ISO 52000-1.  1 

Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 1: General

ICS
91.060.50;91.120.10
CCS
Q70
发布
2017-06
实施

This document specifies a method and gives reference input data for the calculation of the thermal transmittance of frame profiles and of the linear thermal transmittance of their junction with glazing or opaque panels. The method can also be used to evaluate the thermal resistance of shutter profiles and the thermal characteristics of roller shutter boxes and similar components (e.g. blinds). This document also gives criteria for the validation of numerical methods used for the calculation. This document does not include effects of solar radiation, heat transfer caused by air leakage or threedimensional heat transfer such as pinpoint metallic connections. Thermal bridge effects between the frame and the building structure are not included. NOTE Table 1 in the Introduction shows the relative position of this document within the set of EPB standards in the context of the modular structure as set out in ISO 52000-1.

Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 2: Numerical method for frames

ICS
91.060.50;91.120.10
CCS
Q70
发布
2017-06
实施

This document provides the method of calculation of the thermal resistance and thermal transmittance of building components and building elements, excluding doors, windows and other glazed units, curtain walling, components which involve heat transfer to the ground, and components through which air is designed to permeate. The calculation method is based on the appropriate design thermal conductivities or design thermal resistances of the materials and products for the application concerned. The method applies to components and elements consisting of thermally homogeneous layers (which can include air layers). This document also provides an approximate method that can be used for elements containing inhomogeneous layers, including the effect of metal fasteners, by means of a correction term given in Annex F. Other cases where insulation is bridged by metal are outside the scope of this document. NOTE Table 1 in the Introduction shows the relative position of this document within the set of EPB standards in the context of the modular structure as set out in ISO 52000-1.

Building components and building elements - Thermal resistance and thermal transmittance - Calculation methods

ICS
91.060.01;91.120.10
CCS
Q70
发布
2017-06
实施

This document specifies the characteristics related to the dynamic thermal behaviour of a complete building component and provides methods for their calculation. It also specifies the information on building materials required for the use of the building component. Since the characteristics depend on the way materials are combined to form building components, this document is not applicable to building materials or to unfinished building components. The definitions given in this document are applicable to any building component. A simplified calculation method is provided for plane components consisting of plane layers of substantially homogeneous building materials. Annex C provides simpler methods for the estimation of the heat capacities in some limited cases. These methods are suitable for the determination of dynamic thermal properties required for the estimation of energy consumption. These approximations are not appropriate, however, for product characterization. NOTE   Table 1 in the Introduction shows the relative position of this document within the set of EPB standards in the context of the modular structure as set out in ISO 52000-1.

Thermal performance of building components - Dynamic thermal characteristics - Calculation methods

ICS
91.060.01;91.120.10
CCS
Q70
发布
2017-06
实施

This document specifies a method to measure the solar heat gain coefficient of complete windows and doors. This document applies to windows and doors a) with various types of glazing (glass or plastic; single or multiple glazing; with or without low emissivity coatings, and with spaces filled with air or other gases), b) with opaque panels, c) with various types of frames (wood, plastic, metallic with and without thermal barrier or any combination of materials), d) with various types of shading devices (blind, screen, film or any attachment with shading effects), e) with various types of active solar fenestration systems [building-integrated PV systems (BIPV) or building-integrated solar thermal collectors (BIST)]. This document does not include the following: a) shading effects of building elements (e.g. eaves, sleeve wall, etc.); b) heat transfer caused by air leakage between indoors and outdoors; c) ventilation of air spaces in double and coupled windows; d) thermal bridge effects at the rebate or joint between the window or door frame and the rest of the building envelope. This document does not apply to the following: a) non-vertical windows; b) curtain walls; c) industrial, commercial and garage doors.

Thermal performance of windows and doors - Determination of solar heat gain coefficient using solar simulator

ICS
91.060.50;91.120.10
CCS
Q70
发布
2017-04
实施

Power operated pedestrian doorsets -- Safety

ICS
91.060.50
CCS
Q70
发布
2017-03-21
实施

Windows and doors - Air permeability - Classification; German version EN 12207:2016

ICS
91.060.50
CCS
Q70
发布
2017-03
实施

Fences. Specification for electric security fences. Design, installation and maintenance

ICS
91.090
CCS
Q70
发布
2017-02-28
实施
2017-02-28

Windows and doors. Air permeability. Classification

ICS
91.060.50
CCS
Q70
发布
2017-01-31
实施
2017-01-31

Finger protection devices for pedestrian doors. Specification. Safety requirements and test methods

ICS
13.340.40;91.060.50
CCS
Q70
发布
2017-01-31
实施
2017-01-31

Power operated pedestrian doors - Product standard, performance characteristics - Pedestrian doorsets, other than swing type, initially designed for installation with power operation; German version EN 16361:2013+A1:2016

ICS
91.060.50
CCS
Q70
发布
2016-12
实施

Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets; German version EN 14351-1:2006+A2:2016

ICS
91.060.50
CCS
Q70
发布
2016-12
实施

Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 5: Fire resistance of hinged and pivoted metal framed glazed doorsets and

ICS
13.220.50;91.060.50
CCS
Q70
发布
2016-12
实施

Windows and doors - Resistance to wind load - Test method; German version EN 12211:2016

ICS
91.060.50
CCS
Q70
发布
2016-10
实施

房屋建筑、道路、桥梁、水坝等土木工程施工中的轮扣式钢管脚手架的设计、施工、验收和使用

Safety technical regulations for wheel buckle steel pipe scaffolding

ICS
91.060.01
CCS
Q70
发布
2016-09-08
实施
2017-01-01

Windows and doors - Water tightness - Test method; German version EN 1027:2016

ICS
91.060.50
CCS
Q70
发布
2016-09
实施

Windows and doors - Air permeability - Test method; German version EN 1026:2016

ICS
91.060.50
CCS
Q70
发布
2016-09
实施

Windows and doors - Resistance to wind load - Classification; German version EN 12210:2016

ICS
91.060.50
CCS
Q70
发布
2016-09
实施

Curtain walling. Terminology

ICS
01.040.91;91.060.10
CCS
Q70
发布
2016-07-31
实施
2016-07-31

Windows and doors. Resistance to wind load. Test method

ICS
91.060.50
CCS
Q70
发布
2016-06-30
实施
2016-06-30