Q83 供热器材设备 标准查询与下载



共找到 818 条与 供热器材设备 相关的标准,共 55

UL proposes the following change to UL 1482: Addition and revision of requirements to relocate component Standard references from Appendix A into the body of the Standard as component requirements.

Standard for Safety for Solid-Fuel Type Room Heaters

ICS
97.100.30
CCS
Q83
发布
2011
实施

UL proposes the following changes to UL 737: Addition and revision of requirements to relocate component Standard references from Appendix A into the body of the Standard as component requirements.

Standard for Safety for Fireplace Stoves

ICS
97.100.30
CCS
Q83
发布
2011
实施

UL proposes the following change to UL 127: Addition and revision of requirements to relocate component Standard references from Appendix A into the body of the Standard as component requirements

Standard for Safety for Factory-Built Fireplaces

ICS
97.100.30
CCS
Q83
发布
2011
实施

1.1 Scope 1.1.1 This recommended practice shall apply to fluid heaters including thermal fluid heaters and process fluid heaters. 1.1.2 The fluid shall be flowing, under pressure, and indirectly heated. 1.1.3 This recommended practice shall not apply to water or steam heaters

Recommended Practice for Fluid Heaters

ICS
97.100.01
CCS
Q83
发布
2011
实施

UL proposes the following changes to UL 737: Addition and revision of requirements to relocate component Standard references from Appendix A into the body of the Standard as component requirements.

Standard for Safety for Fireplace Stoves

ICS
97.100.30
CCS
Q83
发布
2011
实施

This test method is used for determining emission factors and emission rates for cordwood or other densified, binder free biomass fuel burning masonry heaters. The emission factor is useful for determining emission performance during product development. The emission factor is useful for the air quality regulatory community for determining compliance with emission performance limits. The emission rate may be useful for the air quality regulatory community for determining impacts on air quality from masonry heaters, but must be used with caution as use patterns must be factored into any prediction of atmospheric particulate matter impacts from masonry heaters based on results from this method. The reporting units are grams of particulate per kilogram of dry fuel (emissions factor), grams of particulate per hour of heating cycle (heating cycle emissions rate, based on the builder or manufacturer’s specified firing interval), and grams of particulate per hour of test run (combustion period emissions rate, based on the tested combustion period). Warning8212;Use of masonry heater emissions rate reporting numbers (grams per hour) for comparative purposes with other solid fuel burning appliances will require careful study of each of the appliance’s comparative operating characteristics in the given application. Intermittently fired appliances such as masonry heaters and continuously fired appliances such as wood and pellet stoves are not accurately compared by their respective emissions rates.1.1 This test method covers the fueling and operating protocol for determining particulate matter emissions from solid fuel biomass (cordwood or other densified, binder free biomass fuels) fires in masonry heaters. It may also be used to test other similar appliances (see 3.2.20). 1.2 This test method is applicable to the operation and fueling of masonry heaters during particulate emissions measurement test periods. The prescribed methods and procedures of these protocols are performed on masonry heaters installed and operated in accordance with the builder or manufacturer’s specifications. 1.3 In conjunction with Test Method E2515, this test method provides a protocol for laboratory emissions testing of masonry heaters that is intended to simulate actual use in residential homes and other consumer applications. Since such actual use involves almost solely cordwood fueling, Annex A1, Cordwood Fuel, provides as close a simulation as is currently possible of consumer use, and is recommended for predicting actual consumer emissions performance. For regulatory and other potential uses in comparing relative emissions of various masonry heater products and designs, Annex A2, Cribwood Fueling, and Annex A3, Cribwood Fuel, Top-Down Burn, provide optional additional fueling protocols that substitute dimensional lumber cribs for the cordwood fuel. Data that establish the relationships between the emissions results generated by Annex A2 and Annex A3 and the emissions results generated by Annex A1 are not currently available. 1.4 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Method for Test Fueling Masonry Heaters

ICS
97.100.30
CCS
Q83
发布
2011
实施

Proposal topics include: 1) Addition and Revision of Requirements to Relocate Component Standard References from Appendix A into the Body of the Standard for Component Requirements; and 2) Addition of New Requirements for Motors, Motor Overload Protection and Low Voltage Transformers.

Standard for Safety for Electric Booster and Commercial Storage Tank Water Heaters (Proposal document dated 04-29-11)

ICS
91.140.65
CCS
Q83
发布
2011
实施

The purpose of this standard is to provide methods of testing and rating pool heaters

Methods of Testing and Rating Pool Heaters

ICS
97.100.01
CCS
Q83
发布
2011
实施

Gas-fired central heating boilers. Type C boilers of nominal heat input exceeding 70 kW, but not exceeding 1000 kW

ICS
91.140.10
CCS
Q83
发布
2010-12-31
实施
2010-12-31

本标准规定了压铸铝合金散热器的术语和定义、型号与标记、要求、试验方法、检验规则、标志、包装、运输和贮存等。 本标准适用于以热水为热媒,工作压力不大于1.0MPa,热媒温度不高于95℃的散热器。 对于整体式和组合式散热器,热水pH值应在7.0~8.5、氯离子含量不应大于30mg/L、溶解氧不应大于0.1mg/L;对于复合式散热器,热水pH值应在7.0~12.0、氯离子含量不应大于300mg/L、溶解氧不应大于0.1mg/L。其他水质指标应符合GB 1576的规定。

Die-casting aluminum alloy radiator

ICS
CCS
Q83
发布
2010-12-20
实施
2011-08-01

本标准规定了热量表检定装置的术语、构成原理、一般规定、技术要求、试验方法、检验规则及标志、包装、运输和贮存条件。 本标准适用于流动介质为水,口径为DN15mm~DN250mm,压力不大于2.5MPa的热量表检定装置。

Verification facilities of heat meters

ICS
CCS
Q83
发布
2010-12-20
实施
2011-07-01

이 표준은 등유를 연료로 하고 연료 소비량1)이 600 g/h 이하인 자연 통기형 개방식2

Open type natural ventilating oil burning space heaters

ICS
91.140.20
CCS
Q83
发布
2010-11-05
实施
2010-11-05

이 표준은 액화 석유 가스 또는 도시가스(이하 ‘가스’라 한다.)를 연료로 하는 버너를 가

Open storage type gas water heaters

ICS
27.060.20
CCS
Q83
发布
2010-11-05
实施
2010-11-05

이 표준은 80 ℃ 이하의 온수를 사용하여 바닥을 난방하는 패널[이하 온수패널1)이라 한다

Floor panels for hot water heating

ICS
91.140.00
CCS
Q83
发布
2010-11-05
实施
2010-11-05

이 표준은 액화 석유 가스 또는 도시가스(이하 가스라 한다.)를 연료로 하는 버너를 가지며

Close storage type gas water heaters

ICS
27.060.20
CCS
Q83
发布
2010-11-05
实施
2010-11-05

이 표준은 등유 또는 경유를 연료로 하여 연료 소비량이 1 500 g/h 이하인 강제 통기

Open type forced ventilating oil burning space heaters

ICS
91.140.20
CCS
Q83
发布
2010-11-05
实施
2010-11-05

이 표준은 액화 석유 가스 또는 도시가스(이하 가스라 한다.)를 연료로 하는 버너를 가지고

Gas cooking tables

ICS
97.040.20
CCS
Q83
发布
2010-11-05
实施
2010-11-05

이 표준은 연료 소비량이 600 g/h 이하인 강제 통기형 개방식 기름 난로(이하 난로라

Measurement method of NOx emission rate for open type forced draught oil burning space heaters

ICS
27.060.10
CCS
Q83
发布
2010-11-05
实施
2010-11-05

이 표준은 주로 기름 버너 또는 가스 버너의 점화 회로에 전력을 공급하는 연소 기기용 변압

Ignition transformers for burning appliances

ICS
27.060.10
CCS
Q83
发布
2010-11-05
实施
2010-11-05

이 표준은 등유 또는 경유를 연료로 하고 연료 소비량1)이 3 200 g/h 이하인 반밀폐

Semi closed type oil burning space heaters

ICS
91.140.20
CCS
Q83
发布
2010-11-05
实施
2010-11-05



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号