Q15 墙体材料 标准查询与下载



共找到 481 条与 墙体材料 相关的标准,共 33

1.1 This specification covers thin veneer brick units made from clay, shale, fire clay, sand, or mixtures thereof, and fired to incipient fusion for use in adhered or fastened veneer applications. Three types of thin veneer brick units in each of two grades are covered. In this specification, the term thin veneer brick shall be understood to mean clay masonry unit with a maximum thickness of 13/4 in. (44.45 mm). Note 1: Brick intended for paving should be specified under Specification C902. 1.2 The property requirements of this specification apply at the time of purchase. The use of results from testing of brick extracted from masonry structures for determining conformance or nonconformance to the property requirements (Section 6) of this specification is beyond the scope of this specification. 1.3 Brick covered by this specification are manufactured from clay, shale, or similar naturally occurring substances and subjected to a heat treatment at elevated temperatures (firing). The heat treatment must develop sufficient fired bond between the particulate constituents to provide the strength and durability requirements of the specification. (See “firing” and “fired bond” in Terminology C1232.) 1.4 The text of this specification references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. 1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Thin Veneer Brick Units Made From Clay or Shale

ICS
91.100.15
CCS
Q15
发布
2017
实施

1.1 This specification covers brick intended for use in masonry and supplying structural or facing components, or both, to the structure. 1.2 The requirements of this specification apply at the time of purchase. The use of results from testing of brick extracted from masonry structures for determining conformance or nonconformance to the requirements of this specification is beyond the intent of this specification. 1.3 The brick are prismatic units available in a variety of sizes, textures, colors, and shapes. This specification is not intended to provide specifications for paving brick (see Specification C902). 1.4 Brick are ceramic products manufactured primarily from clay, shale, or similar naturally occurring earthy substances and subjected to a heat treatment at elevated temperatures (firing). Additives or recycled materials are permitted to be included at the option of the manufacturer. The heat treatment must develop a fired bond between the particulate constituents to provide the strength and durability requirements of this specification (see Terminology C1232). 1.5 Brick are shaped during manufacture by molding, pressing, or extrusion, and the shaping method is a way to describe the brick. 1.5.1 This standard and its individual requirements shall not be used to qualify or corroborate the performance of a masonry unit made from other materials, or made with other forming methods, or other means of binding the materials. 1.6 Three types of brick in each of two grades are covered. 1.7 The text of this specification references notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. 1.8 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

Standard Specification for Facing Brick (Solid Masonry Units Made from Clay or Shale)

ICS
91.100.15
CCS
Q15
发布
2017
实施

1.1 This specification covers solid kiln fired brick made from clay, shale, or mixtures thereof suitable for use in masonry construction in contact with the chemicals present in flue gases found in industrial chimneys. These brick are normally used with chemical-resistant mortars. 1.2 Terminology related to industrial floor brick is found in Terminology C1232. 1.3 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Industrial Chimney Lining Brick

ICS
91.100.15
CCS
Q15
发布
2017
实施

1.1 This specification covers brick made principally from sand and lime and intended for use in brick masonry. Two grades of brick are covered: 1.1.1 Grade SW—Brick intended for use where exposed to temperature below freezing in the presence of moisture. Note 1: As a typical example, brick used for foundation courses and parapets in the northeastern quarter of the United States should conform to Grade SW. 1.1.2 Grade MW—Brick intended for use where exposed to temperature below freezing but unlikely to be saturated with water. Note 2: As a typical example, brick exposed in the face of the wall other than parapet or foundations, or brick intended for structures located in regions of the United States characterized by less severe frost action or by drier climate than is found in the northeastern quarter of the United States should conform to Grade MW. 1.1.3 When the term brick is used in this specification, it is understood to mean brick or solid masonry units. 1.2 If brick having a particular color, texture, finish, or uniformity is desired, these features shall be specified separately by the purchaser. 1.3 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Calcium Silicate Brick (Sand-Lime Brick)

ICS
91.100.15
CCS
Q15
发布
2017
实施

1.1 This specification covers solid, kiln fired brick and tile made from clay, shale, or mixtures thereof, suitable for indoor and outdoor use in masonry construction subjected to chemical environments (see Terminology C1232). 1.2 The brick and tile covered herein are intended for use in chemical environments where resistance to thermal shock may be a consideration. The brick and tile are normally used with chemical-resistant mortars. 1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Chemical-Resistant Masonry Units

ICS
91.100.15
CCS
Q15
发布
2017
实施

1.1 This specification covers structural clay loadbearing wall tile. 1.2 The property requirements of this specification apply at the time of purchase. The use of results from testing of tile extracted from masonry structures for determining conformance or non-conformance to the property requirements (Section 5) of this standard is beyond the scope of this specification. 1.3 Tile covered by this specification are manufactured from clay, shale, or similar naturally occurring substances and subjected to a heat treatment at elevated temperatures (firing). The heat treatment must develop sufficient fired bond between the particulate constituents to provide the strength and durability requirements of this specification. (See firing and fired bond in Terminology C1232.) 1.4 The text of this specification references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. 1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Structural Clay Loadbearing Wall Tile

ICS
81.080
CCS
Q15
发布
2017
实施

1.1 This specification covers wet-cast precast modular retaining wall units cast from first-purpose concrete with or without the inclusion of steel reinforcement. The precast units covered by this specification are machine-placed units intended for use in the construction of dry stacked modular retaining wall systems. 1.2 The text of this standard references notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. 1.3 Units—The values stated in either inch-pound units or SI units are to be regarded separately as standard. Within the text of the specification, the SI units are shown in brackets. The values stated in each system are not exact equivalents. Therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Wet-Cast Precast Modular Retaining Wall Units

ICS
91.060.10
CCS
Q15
发布
2017
实施

1.1 This specification covers hollow building brick and hollow facing brick made from clay, shale, fire clay, or mixtures thereof, and fired to incipient fusion. Four types of hollow brick in each of two grades and two classes are covered. In this specification, the term hollow brick shall be understood to mean hollow clay masonry units whose net cross-sectional area (solid area) in any plane parallel to the surface, containing the cores, cells, or deep frogs, is less than 758201;% of its gross cross-sectional area measured in the same plane (see 4.3). This specification does not cover brick intended for use as paving brick (see Specification C902). 1.2 The property requirements of this specification apply at the time of purchase. The use of results from testing of brick extracted from masonry structures for determining conformance or nonconformance to the property requirements (Section 6) of this standard is beyond the scope of this specification. 1.3 Brick covered by this specification are ceramic products manufactured primarily from clay, shale, or similar naturally occurring substances and subjected to a heat treatment at elevated temperatures (firing). The heat treatment shall develop sufficient fired bond between the particulate constituents to provide the strength and durability requirements of this specification. Additives or recycled materials are permitted to be included at the option of the manufacturer. (See “firing” and “firing bond” in Terminology C1232.) 1.3.1 This specification and its individual requirements shall not be used to qualify or corroborate the performance of a masonry unit made from other materials, or made with other forming methods, or other means of binding the materials. 1.4 Hollow brick differ from unglazed structural clay tile (Specifications C34 and C212) and solid brick (Specifications C62 and C216). Hollow brick require greater shell and web thicknesses and higher minimum compressive strength than structural clay tile, but permit greater void area and lesser distance from exposed edge to core hole than solid brick. Therefore, environmental and structural performance may be different in elements constructed of hollow brick from those constructed of structural clay tile or solid brick. 1.5 The text of this specification references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification. 1.6 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.7 This international standard was developed in accordance with internationally recognized principles on standardization estab

Standard Specification for Hollow Brick (Hollow Masonry Units Made From Clay or Shale)

ICS
91.100.15
CCS
Q15
发布
2017
实施

Fly ash for silicate building products

ICS
91.100.99
CCS
Q15
发布
2016-10-22
实施
2017-04-01

本标准规定了建筑隔墙用轻质条板(以下简称轻质条板)的术语和定义、分类与标记、一般要求、要求、试验方法、检验规则、标志、运输和贮存。 本标准适用于一般工业与民用建筑非承重隔墙轻质条板的生产与检验。

General technical requirements of light weight panel used for building partition

ICS
91.060.10
CCS
Q15
发布
2016-09-06
实施
2017-03-01

本标准规定了建筑垃圾再生骨料实心砖的术语和定义、分类与标记、原材料、要求、试验方法、检验规则、养护、标志、包装、运输和贮存。 本标准适用于以建筑垃圾再生骨料为主要原料、水泥等为胶凝材料制成的非烧结实心砖。

Construction wastes recycled aggregate solid brick

ICS
91.100.10
CCS
Q15
发布
2016-08-08
实施
2017-02-01

Construction debris small hollow blocks

ICS
91.100.30
CCS
Q15
发布
2016-07-11
实施
2017-01-01

This European Standard specifies tolerances on dimensions and shape for continuously hot-rolled uncoated patterned steel strip and plate/sheet cut of it in nominal thicknesses up to 20 mm inclusive, of non-alloy and alloy steels in accordance with Table 1 (see also Annex A). This European standard does not apply to stainless steels.

Continuously hot-rolled patterned steel strip and plate/sheet cut from wide strip - Tolerances on dimensions and shape

ICS
77.140.50
CCS
Q15
发布
2016-07
实施

This European Standard specifies the technical delivery conditions for hot rolled weldable steel bars for the construction of pressure equipment for use at elevated temperatures with thicknesses given in Table 5. The general technical delivery conditions in EN 10021 also apply to products supplied in accordance with this European Standard. NOTE Once this European Standard is published in the Official Journal of the European Union (OJEU) under Directive 2014/68/EC, presumption of conformity to the Essential Safety Requirements (ESRs) of Directive 2014/68/EC is limited to technical data of materials in this European Standard and does not presume adequacy of the material to a specific item of equipment. Consequently, the assessment of the technical data stated in this material standard against the design requirements of this specific item of equipment to verify that the ESRs of the Pressure Equipment Directive are satisfied, needs to be done.

Hot rolled weldable steel bars for pressure purposes with specified elevated temperature properties

ICS
77.140.30;77.140.60
CCS
Q15
发布
2016-07
实施

Curtain walling. Determination of the strength of sheared connections. Test method and requirements

ICS
91.060.10
CCS
Q15
发布
2016-06-30
实施
2016-06-30

This European Standard describes techniques for the manual, pulse-echo, ultrasonic testing of forgings manufactured from austenitic and austenitic-ferritic stainless steels. Mechanized scanning techniques, such as immersion testing, may be used but should be agreed between the purchaser and supplier. This part of EN 10228 applies to four types of forgings, classified according to their shape and method of production. Types 1, 2 and 3 are essentially simple shapes. Type 4 covers complex shapes. This part of EN 10228 does not apply to:- closed die forgings; - turbine rotor and generator forgings. Ultrasonic testing of ferritic and martensitic steel forgings is the subject of Part 3 of this European Standard.

Non-destructive testing of steel forgings - Part 4: Ultrasonic testing of austenitic and austenitic-ferritic stainless steel forgings

ICS
77.040.20;77.140.85
CCS
Q15
发布
2016-06
实施

This European Standard describes techniques and acceptance criteria to be used for the magnetic particle testing of forgings manufactured from ferromagnetic materials. The method described is used for the detection of surface discontinuities. It can also detect discontinuities just below the surface but the sensitivity to such discontinuities decreases rapidly with depth. NOTE A steel forging is considered to be ferromagnetic if the magnetic flux density is greater than 1 T for a tangential magnetic field strength of 2,4 kA/m.

Non-destructive testing of steel forgings - Part 1: Magnetic particle inspection

ICS
77.040.20;77.140.85
CCS
Q15
发布
2016-06
实施

This European Standard describes techniques to be used for the manual, pulse-echo, ultrasonic testing of forgings manufactured from ferritic and martensitic steel. Mechanized scanning techniques, such as immersion testing, may be used but should be agreed between the purchaser and supplier. This part of EN 10228 applies to four types of forgings, classified according to their shape and method of production. Types 1, 2 and 3 are essentially simple shapes. Type 4 covers complex shapes. This part of EN 10228 does not apply to:- closed die forgings; - turbine rotor and generator forgings. Ultrasonic testing of austenitic and austenitic-ferritic stainless steel forgings is the subject of EN 10228-4.

Non-destructive testing of steel forgings - Part 3: Ultrasonic testing of ferritic or martensitic steel forgings

ICS
77.040.20;77.140.85
CCS
Q15
发布
2016-06
实施

This European Standard specifies a method for deriving the minimum proof strength values for steels at elevated temperatures. However, this European Standard does not specify a verification procedure.

Method for the derivation of minimum values of proof strength of steel at elevated temperatures

ICS
77.140.30
CCS
Q15
发布
2016-06
实施

This European Standard describes techniques and acceptance criteria to be used for the penetrant testing of steel forgings. The method described is used for the detection of surface discontinuities.

Non-destructive testing of steel forgings - Part 2: Penetrant testing

ICS
77.040.20;77.140.85
CCS
Q15
发布
2016-06
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号