Q15 墙体材料 标准查询与下载



共找到 481 条与 墙体材料 相关的标准,共 33

1.1 This specification covers structural clay loading-bearing wall tile. 1.2 The property requirements of this specification apply at the time of purchase. The use of results from testing of tile extracted from masonry structures for determining conformance or non-conformance to the property requirements (Section 4) of this standard is beyond the scope of this specification. 1.3 Tile covered by this specification are manufactured from clay, shale, or similar naturally occurring substances and subjected to a heat treatment at elevated temperatures (firing). The heat treatment must develop sufficient fired bond between the particulate constituents to provide the strength and durability requirements of this specification. (See firing and fired bond in Terminology C1232.) 1.4 The text of this specification references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. 1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

Standard Specification for Structural Clay Load-Bearing Wall Tile

ICS
81.080 (Refractories)
CCS
Q15
发布
2012
实施

1.1 This specification covers structural clay nonloadbearing tile (partition, fireproofing, and furring). 1.2 The property requirements of this specification apply at the time of purchase. The use of results from testing of tile extracted from masonry structures for determining conformance or non-conformance to the property requirements (Section 4) of this standard is beyond the scope of this specification. 1.3 Tile covered by this specification are manufactured from clay, shale, or similar naturally occurring substances and subjected to a heat treatment at elevated temperatures (firing). The heat treatment must develop sufficient fired bond between the particulate constituents to provide the strength and durability requirements of this specification. (See firing and fired bond in Terminology C1232.) 1.4 Fireproofing tile intended for use in load-bearing masonry shall conform to Specification C34. 1.5 Tile intended for use in fireproofing structural members shall be of such sizes and shapes that they can be erected to cover completely the exposed surfaces of the members. 1.6 The text of this specification references notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this specification. 1.7 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

Standard Specification for Structural Clay Nonloadbearing Tile

ICS
81.080 (Refractories)
CCS
Q15
发布
2012
实施

1.1 This specification covers hollow building brick and hollow facing brick made from clay, shale, fire clay, or mixtures thereof, and fired to incipient fusion. Four types of hollow brick in each of two grades and two classes are covered. In this specification, the term hollow brick shall be understood to mean hollow clay masonry units whose net cross-sectional area (solid area) in any plane parallel to the surface, containing the cores, cells, or deep frogs, is less than 758201;% of its gross cross-sectional area measured in the same plane (see 4.3). This specification does not cover brick intended for use as paving brick (see Specification C902). 1.2 The property requirements of this specification apply at the time of purchase. The use of results from testing of brick extracted from masonry structures for determining conformance or nonconformance to the property requirements (Section 6) of this standard is beyond the scope of this specification. 1.3 Brick covered by this specification are ceramic products manufactured primarily from clay, shale, or similar naturally occurring substances and subjected to a heat treatment at elevated temperatures (firing). The heat treatment shall develop sufficient fired bond between the particulate constituents to provide the strength and durability requirements of this specification. Additives or recycled materials are permitted to be included at the option of the manufacturer. (See ???firing??? and ???firing bond??? in Terminology C1232.) 1.4 Hollow brick differ from unglazed structural clay tile (Specifications C34 and C212) and solid brick (Specifications C62 and C216). Hollow brick require greater shell and web thicknesses and higher minimum compressive strength than structural clay tile, but permit greater void area and lesser distance from exposed edge to core hole than solid brick. Therefore, environmental and structural performance may be different in elements constructed of hollow brick from those constructed of structural clay tile or solid brick. 1.5 The text of this specification references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification. 1.6 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

Standard Specification for Hollow Brick (Hollow Masonry Units Made From Clay or Shale)

ICS
91.100.15 (Mineral materials and products)
CCS
Q15
发布
2012
实施

1.1 This test method covers procedures for masonry prism construction and testing, and procedures for determining the compressive strength of masonry, fmt, used to determine compliance with the specified compressive strength of masonry, f8201;???m. When this test method is used for research purposes, the construction and test procedures within serve as a guideline and provide control parameters. 1.2 This test method also covers procedures for determining the compressive strength of prisms obtained from field-removed masonry specimens. 1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Method for Compressive Strength of Masonry Prisms

ICS
19.060 (Mechanical testing); 91.080.30 (Masonry)
CCS
Q15
发布
2012
实施

1.1 This specification covers unglazed, structural clay, nonloadbearing screen tile. 1.2 The property requirements of this specification apply at the time of purchase. The use of results from testing of tile extracted from masonry structures for determining conformance or nonconformance to the property requirements (Section 4) of this specification is beyond the scope of this standard. 1.3 Tile covered by this specification are manufactured from clay, shale, or similar naturally occurring substances and subjected to a heat treatment at elevated temperatures (firing). The heat treatment must develop sufficient fired bond between the particulate constituents to provide the strength and durability requirements of this specification. (See firing and fired bond in Terminology C1232). 1.4 The text of this specification references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification. 1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

Standard Specification for Structural Clay Nonloadbearing Screen Tile

ICS
81.080 (Refractories)
CCS
Q15
发布
2012
实施

1.1 This specification covers solid, kiln fired brick and tile made from clay, shale, or mixtures thereof, suitable for indoor and outdoor use in masonry construction subjected to chemical environments (see Terminology C1232). 1.2 The physical and chemical properties of brick and tile differ from supplier to supplier, mainly because their composition is determined by the source of raw materials. Regardless of the differences, brick and tile are considered to be one of three types and one of two classes as follows: 1.2.1 Type I???For use where low absorption and high acid resistance are not major factors. 1.2.2 Type II???For use where lower absorption and higher acid resistance are required. 1.2.3 Type III???For use where minimum absorption and maximum acid resistance are required. Note 1???Types I, II, and III may not differ significantly in thermal shock resistance. The suitability of a given brick, for a particular application should be determined at the time of purchase by agreement between the purchaser and the supplier.Note 2???Types I and III were formerly designated Type ???H'' and ???L'' respectively. 1.2.4 Class S???For use in standard applications. 1.2.5 Class X???For use where a higher degree of precision and lower permissible variation in size than that permitted for Class S is required. 1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Chemical-Resistant Masonry Units

ICS
91.100.15
CCS
Q15
发布
2012
实施

1.1 This specification covers brick, having a ceramic glaze finish fused to the body during the same process as the unit body firing, that are intended for use in masonry and supplying structural or facing components, or both, to the structure. This specification does not cover double-fired glazed brick. Some double-fired decorative glazes have physical properties which vary from those of single-fired glazes due to the lower temperatures used in applying the decorative coating. 1.2 The property requirements of this specification apply at the time of purchase. The use of results from testing of brick extracted from masonry structures for determining conformance or nonconformance to the property requirements of this specification is beyond the scope of this specification. 1.3 Glazed brick are prismatic units available in a variety of sizes, textures, colors, and shapes. Glazed brick are manufactured from clay, shale, or similar naturally occurring earthy substances and subjected to a heat treatment at elevated temperatures (firing). The heat treatment shall develop a fired bond between the particulate constituents to provide the strength and durability requirements of this specification (see Terminology C1232). 1.4 Glazed brick are shaped during manufacture by molding, pressing, or extrusion, and the shaping method is a way to describe the brick. 1.5 Glazed brick are classified into one of two grades, one of two types, one of two classes, and one of three divisions. 1.6 Opacity of the glaze is not required unless specified by the purchaser. 1.7 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this standard. 1.8 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Glazed Brick (Single Fired, Brick Units)

ICS
91.100.15 (Mineral materials and products)
CCS
Q15
发布
2012
实施

Lightweight Particleboards - Specifications

ICS
79.060.20
CCS
Q15
发布
2011-12-01
实施

Specification for masonry units. Calcium silicate masonry units

ICS
91.100.25
CCS
Q15
发布
2011-11-30
实施
2011-11-30

Common bricks and facing bricks

ICS
91.100.25
CCS
Q15
发布
2011-11-21
实施

Specification for masonry units. Clay masonry units

ICS
91.100.25
CCS
Q15
发布
2011-10-31
实施
2011-10-31

Specification for masonry units. Aggregate concrete masonry units (dense and lightweight aggregates)

ICS
91.100.30
CCS
Q15
发布
2011-10-31
实施
2011-10-31

本标准适用于工业与民用建筑用自保温砌块。

Foaming self-conserving concrete block with the concrete cavitye of match type

ICS
91.060.10
CCS
Q15
发布
2011-10-25
实施
2011-11-25

Technical specification for application of interior partition panels in rural buildings

ICS
CCS
Q15
发布
2011-10-01
实施
2011-10-01

Methods of test for masonry units - Part 21 : determination of water absorption of clay and calcium silicate masonry units by cold water absorption.

ICS
91.100.15
CCS
Q15
发布
2011-08-01
实施
2011-08-06

Specification for masonry units - Part 5 : manufactured stone masonry units.

ICS
91.100.30
CCS
Q15
发布
2011-08-01
实施
2011-08-06

Methods of test for masonry units - Part 1 : determination of compressive strength.

ICS
91.100.25
CCS
Q15
发布
2011-08-01
实施
2011-08-06

Methods of test for masonry units - Part 11 : determination of water absorption of aggregate concrete, autoclaved aerated concrete, manufactured stone and natural stone masonry units due to capillary action and the initial rate of water absorption of clay

ICS
91.100.15;91.100.30
CCS
Q15
发布
2011-08-01
实施
2011-08-06

Specification for masonry units - Part 1 Clay masonry units.

ICS
91.100.25
CCS
Q15
发布
2011-08-01
实施
2011-08-06

This European Standard specifies a method of determining the overall dimensions, thickness and combined thickness of shells and webs, depth of voids and plane parallelism of the bed faces of masonry units.

Methods of test for masonry units - Part 16: Determination of dimensions; German version EN 772-16:2011

ICS
91.100.25
CCS
Q15
发布
2011-07
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号