23.040.20 塑料管 标准查询与下载



共找到 2040 条与 塑料管 相关的标准,共 136

Thermoplastics pipes — Determination of tensile properties — Part 2: Pipes made of unplasticized poly(vinyl chloride)(PVC-U), oriented unplasticized poly(vinyl chloride)(PVC-O), chlorinated poly(vinyl

ICS
23.040.20
CCS
发布
2022-11-02
实施

Glass-reinforced thermosetting plastic (GRP) pipes — Test methods for the determination of the initial circumferential tensile wall strength

ICS
23.040.20
CCS
发布
2022-11-02
实施

Thermoplastics pipes — Universal wall thickness table

ICS
23.040.20
CCS
发布
2022-11-02
实施

Glass-reinforced thermosetting plastic (GRP) pipes — Test methods for the determination of the initial circumferential tensile wall strength

ICS
23.040.20
CCS
发布
2022-11-02
实施

Acrylonitrile-butadiene-styrene(ABS) sheets

ICS
23.040.20
CCS
发布
2022-11-02
实施

Testing method for in-plane shear properties of glass fiber reinforced plastics

ICS
23.040.20
CCS
发布
2022-11-02
实施

Thermoplastics pipes for the conveyance of fluids — Dimensions and tolerances — Part 1: Metric series

ICS
23.040.20
CCS
发布
2022-11-02
实施

Thermoplastics pipes for the conveyance of fluids — Dimensions and tolerances — Part 1: Metric series

ICS
23.040.20
CCS
发布
2022-11-02
实施

Thermoplastics pipes — Determination of tensile properties — Part 2: Pipes made of unplasticized poly(vinyl chloride)(PVC-U), oriented unplasticized poly(vinyl chloride)(PVC-O), chlorinated poly(vinyl

ICS
23.040.20
CCS
发布
2022-11-02
实施

1.1 This specification covers polyethylene (PE) pipe made to standard inside dimension ratios (SIDR) and pressure rated for water (see appendix). Included are requirements for PE compounds and requirements and test methods for workmanship, dimensions, elevated temperature sustained pressure, burst pressure, and marking. NOTE 1—Refer to specification AWWA C901and PPI Technical Note 49 (TN-49) for further information on pipe suitability for potable water end use applications. Oxidative Resistance Classification (CC# rating) information is available from NSF International. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 The text of this specification references notes, footnotes, and appendixes which provide explanatory material. These notes and footnotes shall not be considered as requirements of the specification. Notes and footnotes in tables and figures, and Supplementary Requirements are requirements of the specification. 1.4 The following safety hazards caveat pertains only to the test methods portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Polyethylene (PE) Plastic Pipe (SIDR-PR) Based on Controlled Inside Diameter

ICS
23.040.20
CCS
发布
2022-11-01
实施

1.1 This specification covers requirements for non-pressure polyolefin pipe and fittings for corrosive waste drainage systems. 1.2 Pipe is produced in Schedule 40 and 80 IPS sizes, and in DR IPS sizes for two polyolefins, polyethylene (PE) and polypropylene (PP). 1.3 The interchangeability of pipe and fittings made by different manufacturers is not addressed in this specification. Transition fittings for joining pipe and fittings of different manufacturers is provided for in this specification. 1.4 Pipe and fittings are joined by the heat fusion method ( Practice D2657 for PP butt and saddle fusion, Practice F2620 for PE butt, saddle and socket fusion and Practice F1290 for polyolefin electrofusion) or by using mechanical joints recommended by the manufacturer. 1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.6 The following safety hazards caveat pertains only to the test method, Section 8, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Polyolefin Pipe and Fittings for Corrosive Waste Drainage Systems

ICS
23.040.20
CCS
发布
2022-11-01
实施

1.1 This specification covers polyethylene (PE) plastic tubing in outside diameters and SDR’s that are pressure rated for water. Included are requirements for PE compounds, and requirements and test methods for PE plastic tubing workmanship, dimensions, elevated temperature sustained pressure, burst pressure and marking. NOTE 1—Refer to specification AWWA C901 and PPI Technical Note 49 (TN-49) for further information on pipe suitability for potable water end use applications. Oxidative Resistance Classification (CC# rating) information is available from NSF International. 1.2 The text of this specification references notes, footnotes, and appendixes which provide explanatory material. These notes and footnotes shall not be considered as requirements of the specification. Notes and footnotes in tables and figures, and Supplementary Requirements are requirements of the specification. 1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. NOTE 2—Joining PE plastic tubing with fittings that require flaring the tubing is not recommended because Practice D3140, the technique used to make the flare has been withdrawn (discontinued). 1.4 The following safety hazards caveat pertains only to the test methods portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Polyethylene (PE) Plastic Tubing

ICS
23.040.20
CCS
发布
2022-11-01
实施

1.1 This specification covers polyethylene (PE) pipe made in thermoplastic pipe dimension ratios based on outside diameter IPS 1⁄2 to 3, for both non-pressure and pressure rated water (see Appendix X1). Included are requirements for polyethylene compounds and PE plastic pipe, a system of nomenclature for PE plastic pipe, and requirements and test methods for materials, workmanship, dimensions, sustained pressure, and burst pressure. Methods of marking are also given. NOTE 1—Significant changes have been made to this specification to remedy duplication of sizes with other specifications, for DIPS sizes and larger sizes refer to the appropriate standard specification such as Specification F714 or AWWA C906. 1.2 For pipes produced under this specification that are intended for use in the distribution and transmission of potable water without oxidizing disinfectants, potable and non-potable water, grey water, reclaimed water, wastewater, force main and gravity municipal sewage, etc, the user should consult the manufacturer to determine whether the fluid being transported is compatible with polyethylene pipe and will not affect the service life beyond limits acceptable to the user. 1.3 For pipes produced under this specification that are intended for use in the distribution and transmission of potable water or other fluids containing oxidizing disinfectants (for example, Hypochlorous acid or chloramines), special requirements for PE compounds are specified in 5.2 and 5.3, and DR limitations are specified in 6.2.1.1 and 6.2.2.1. NOTE 2—Refer to specification AWWA C901 for other suitable potable water options. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 The following safety hazards caveat pertains only to the test methods portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based on Controlled Outside Diameter

ICS
23.040.20
CCS
发布
2022-11-01
实施

1.1 This specification covers electrofusion polyethylene fittings for use with outside diameter-controlled polyethylene pipe, covered by Specifications D2513, D2737, D3035, F714, F2623, F2769 and crosslinked polyethylene (PEX), covered by Specifications F876 and F2788/F2788M. Requirements for materials, workmanship, and testing performance are included. All requirements for joining PE electrofusion fittings to PE pipe shall also apply to joining PE electrofusion fittings to PEX pipe. Where applicable in this specification “pipe” shall mean “pipe” or “tubing.” 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 The following safety hazards caveat pertains only to the test method portion, Section 9, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Electrofusion Type Polyethylene Fittings for Outside Diameter Controlled Polyethylene and Crosslinked Polyethylene (PEX) Pipe and Tubing

ICS
23.040.20
CCS
发布
2022-11-01
实施

This document, in conjunction with ISO 11296‑1, specifies the requirements and test methods for pipes and fittings for the renovation of underground non-pressure drainage and sewerage networks by lining with a single rigid annulus of structural cementitious grout formed behind a plastics inner layer. This plastics layer serves as permanent formwork anchored to the grout. This document is applicable to plastics inner layers and grout systems with or without steel reinforcement. It does not apply to the structural design of the lining system. NOTE Systems with multiple annuli are available, but these are controlled by patent rights and not covered by this document.

Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks - Part 9: Lining with a rigidly anchored plastics inner layer (ISO 11296-9:2022)

ICS
23.040.20
CCS
发布
2022-10-12
实施
2023-01-31

1.1 This specification covers socket fusion tools for use in making socket fusion joints between polyethylene pipe or tubing and fittings as specified by Specifications D3035, D2513, and D2683. This specification covers newly manufactured heater faces and used heater faces which have been recoated. Requirements for materials, workmanship, and dimensions are included. Where applicable on this specification, “pipe” shall mean “pipe” and “tubing.” 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Socket Fusion Tools for Use in Socket Fusion Joining Polyethylene Pipe or Tubing and Fittings

ICS
23.040.20
CCS
发布
2022-10-01
实施

1.1 This specification covers requirements and test methods for materials, dimensions and tolerances, deflection load, crush resistance, flattening resistance, impact resistance, and solvent cement. A form of marking is also included. Plastic which does not meet the material requirements specified in Section 5 is excluded. NOTE 1—This specification was formerly issued under the title, 3-in. Thin Wall Poly(Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings. 1.1.1 Techniques for making solvent-cement joints are given in Practice D2855. 1.2 The text of this specification references notes, footnotes, and appendixes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification. 1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.4 The following precautionary caveat pertains only to the test methods portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for 3.25-in. Outside Diameter Poly(Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings

ICS
23.040.20
CCS
发布
2022-10-01
实施

1.1 This practice describes the procedures for the impregnation of 2 in. to 48 in. (50 mm to 1200 mm) diameter cured-in-place pipe utilizing mobile, automated systems. Temporary impregnation facilities set up at the jobsite (“over-thehole” wet outs) are not covered under this standard. Once resin saturation is complete, the wet out liner is then used to rehabilitate existing gravity flow or pressure pipelines, process piping, electrical conduits or ventilation systems. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Practice for Utilization of Mobile, Automated Cured-In-Place Pipe (CIPP) Impregnation Systems

ICS
23.040.20
CCS
发布
2022-10-01
实施
2022-10-01

1.1 This specification covers the classification and identification of rigid plastic compounds intended for use in making nonpressure piping products composed of (1) poly(vinyl chloride) polymer, (2) chlorinated poly(vinyl chloride) polymer, or (3) vinyl chloride copolymers, and the necessary compound ingredients. Compounding ingredients consist of lubricants; stabilizers; non-poly(vinyl chloride) resin modifiers; colorants or pigments, or both; fibrous or nonfibrous reinforcements; or fillers. 1.2 The requirements in this specification are intended for the quality control of compounds used to manufacture pipe or fittings intended for nonpressure use. Specific properties are not directly applicable to finished products. When specified in a product or application standard, the series of classification properties in this standard form a basis for a material specification. See the applicable ASTM standards or requirements for finished products. 1.3 In special cases, specific compounds for unusual piping applications that require consideration of other properties not covered in this specification, such as service temperature, sag resistance, special chemical resistance, weather resistance, bending forces, and electrical properties, shall be considered. 1.4 Rigid PVC-type compounds for building applications other than piping are covered in Specification D4216. 1.5 Rigid PVC compounds for general purpose extrusion, molding, fitting, and pipe are covered in Specification D1784. 1.6 The rate of burning test, Test Method D635, is used in this specification as a test for identification of certain properties of the compound. 1.7 It is acceptable for rigid PVC and CPVC recycle plastics meeting the requirements of this specification to be used in some applications. Refer to the specific requirements in the Material and Manufacture section of the applicable product standard. 1.8 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only. 1.9 The following safety hazards caveat pertains only to the test methods portion, Section 10, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. NOTE 1—There is no known ISO equivalent to this standard. 1.10 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Rigid Poly(Vinyl Chloride) (PVC) and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds for Plastic Pipe and Fittings Used in Nonpressure Applications

ICS
23.040.20
CCS
发布
2022-09-01
实施

1.1 This practice describes the procedures for the reconstruction of pipelines and conduits (2 in. to 108 in. diameter) by the installation of a resin-impregnated, flexible tube which is inverted into the existing conduit by use of a hydrostatic head or air pressure. The resin is cured by circulating hot water, introducing controlled steam within the tube, or by photoinitiated reaction. When cured, the finished pipe will be continuous and tight-fitting. This reconstruction process is used in a variety of gravity and pressure applications such as sanitary sewers, storm sewers, process piping, electrical conduits, and ventilation systems. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see 7.4.2. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Practice for Rehabilitation of Existing Pipelines and Conduits by the Inversion and Curing of a Resin-Impregnated Tube

ICS
23.040.20
CCS
发布
2022-08-15
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号