29.160.20 发电机 标准查询与下载



共找到 218 条与 发电机 相关的标准,共 15

Rotating electrical machines-Part 3:Specific requirements for synchronous generators driven by steam turbines or combustion gas turbines

ICS
29.160.20
CCS
发布
2008-11-28
实施

This part of IEC 60034 applies to three-phase synchronous generators, having rated outputs of 10 MVA and above driven by steam turbine or combustion gas turbine. It supplements the basic requirements for rotating machines given in IEC 60034-1.Common requirements are prescribed together with specific requirements for air, for hydrogen or for liquid cooled synchronous generators.This part of IEC 60034 also gives the precautions to be taken when using hydrogen cooledgenerators including:– rotating exciters driven by synchronous generators;– auxiliary equipment needed for operating the generators;– parts of the building where hydrogen might accumulate.NOTE 1 Th

Rotating electrical machines - Part 3: Specific requirements for synchronous generators driven by steam turbines or combustion gas turbines

ICS
29.160.20
CCS
发布
2008-11-05
实施
2008-11-05

This part of IEC 60034 applies to three-phase synchronous generators, having rated outputs of 10 MVA and above driven by steam turbines or combustion gas turbines. It supplements the basic requirements for rotating machines given in IEC 60034-1. Common requirements are prescribed together with specific requirements for air, for hydrogen or for liquid cooled synchronous generators. This part of IEC 60034 also gives the precautions to be taken when using hydrogen cooled generators including: – rotating exciters driven by synchronous generators; – auxiliary equipment needed for operating the generators; – parts of the building where hydrogen might accumulate. NOTE 1 These requirements also apply to a synchronous generator driven by both a steam turbine and a combustion gas turbine as part of a single shaft combined cycle unit. NOTE 2 These requirements do not apply to synchronous generators driven by water (hydraulic) turbine or wind turbine. NOTE 3 The precautions to be taken when using hydrogen are valid for all cases where hydrogen is used as a coolant.

Rotating electrical machines -Part 3: Specific requirements for synchronous generators driven by steam turbines or combustion gas turbines

ICS
29.160.20
CCS
K21
发布
2008-09-30
实施
2008-09-30

Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks

ICS
29.160.20
CCS
发布
2008-05-30
实施
2008-05-30

Applies to three-phase synchronous generators, having rated outputs of 10 MVA and above driven by steam turbines and combustion gas turbines. It supplements the basic requirements for rotating machines given in SANS 60034-1.

Rotating electrical machines Part 3: Specific requirements for synchronous generators driven by steam turbines or combustion gas turbines

ICS
29.160.20
CCS
K21
发布
2008-04-11
实施

Specifies guidelines and technical requirements for the interfacing of low-voltage generators with the local supply network, and to ensure that they do not compromise the network integrity or safety of the utility or the user.

Guidelines for the installation and safe use of portable generators on utilities' networks

ICS
29.160.20
CCS
P91
发布
2008-02-13
实施

This part of IEC 60034 applies to three-phase synchronous generators, having rated outputs of 10 MVA and above driven by steam turbines or combustion gas turbines. It supplements the basic requirements for rotating machines given in IEC 60034-1. Common requirements are prescribed together with specific requirements for air, for hydrogen or for liquid cooled synchronous generators. This part of IEC 60034 also gives the precautions to be taken when using hydrogen cooled generators including: – rotating exciters driven by synchronous generators; – auxiliary equipment needed for operating the generators; – parts of the building where hydrogen might accumulate. NOTE 1 These requirements also apply to a synchronous generator driven by both a steam turbine and a combustion gas turbine as part of a single shaft combined cycle unit. NOTE 2 These requirements do not apply to synchronous generators driven by water (hydraulic) turbine or wind turbine. NOTE 3 The precautions to be taken when using hydrogen are valid for all cases where hydrogen is used as a coolant.

Rotating electrical machines - Part 3: Specific requirements for synchronous generators driven by steam turbines or combustion gas turbines

ICS
29.160.20
CCS
K20
发布
2007-11
实施
2007-11-29

本标准规定了125MW及以上发电机内冷水的处理方法。 本标准适用于125MW及以上汽轮发电机和水轮发电机内冷水的处理。

Directive for electric power generator inner cooling water treatment

ICS
29.160.20
CCS
K52;K21
发布
2007-07-20
实施
2007-12-01

本标准规定了发电机励磁系统技术监督的目的、任务、内容、组织和职责。 本标准适用于接入220kV及以上电网中的发电机励磁系统,和对电力系统稳定有显著影响的110kV电网中的发电机励磁系统。 其他发电机励磁系统可参照执行。

Guide for technology supervision in generator excitation system

ICS
29.160.20
CCS
K52;K21
发布
2007-07-20
实施
2007-12-01

Some equations in Annex A.2 (Phasor diagram analysis) are corrected in this document.

Guide for Generator Ground Protection - Corrigendum 1: Annex A.2 Phasor Analysis (Informative)

ICS
29.160.20
CCS
K20
发布
2007
实施

本标准规定了透平同步发电机用交流励磁机的型式、技术要求、试验项目以及标志、包装、运输和保管等要求。 本标准适用于透平型同步发电机用的交流励磁机。 凡本标准中未规定的事项,均应符合GB 755中的有关规定。

Technical requirements of AC exciter for turbine-type synchronous generators

ICS
29.160.20
CCS
K21
发布
2006-12-31
实施
2007-07-01

This part of BS 5000 specifies requirements for the vibration resistance of generators, together with their exciters, to be driven by reciprocating internal combustion (RIC) engines. The standard is applicable to generators with a maximum continuous rating with outputs greater than 0.75 kW or kVA per 1 000 r/min, of the following types: a) salient pole alternating current generators; b) cylindrical rotor (distributed field) alternating current generators; c) direct current generators. This part of BS 5000 is not applicable to generators intended for use in ships, traction vehicles or turbine type machines.

Rotating electrical machines of particular types or for particular applications - Part 3: Generators to be driven by reciprocating internal combustion engines - Requirements for resistance to vibration

ICS
29.160.20
CCS
K26
发布
2006-09-29
实施
2006-09-29

Covers general recommendations for the operation, loading, and maintenance of turbine-driven synchronous generators that have cylindrical rotors.

Guide for the Operation and Maintenance of Turbine Generators

ICS
29.160.20
CCS
K20
发布
2006-04-17
实施

This part of IEC 60034 applies to three-phase cylindrical rotor synchronous machines, having rated outputs of 10 MVA (or MW) and above. It supplements the basic requirements for rotating machines given in IEC 60034-1. The special requirements of machines continuously fed by inverters are not covered by this standard. Common requirements for all cylindrical rotor machines are prescribed together with specific requirements for air, for hydrogen or for liquid cooled cylindrical rotor synchronous machines. This part of IEC 60034 also gives the precautions to be taken when using hydrogen cooled machines including – rotating exciters driven by cylindrical rotor type machines; – auxiliary equipment needed for operating the machines; – parts of the building where hydrogen might accumulate.

Rotating electrical machines — Part 3: Specific requirements for cylindrical rotor synchronous machines

ICS
29.160.20
CCS
K21
发布
2006-02-14
实施
2006-02-14

Intended to assist protection engineers in applying and relaying schemes for protection against stator ground faults on various generator grounding schemes.

Generator ground protection

ICS
29.160.20
CCS
K20
发布
2006
实施

Electrical apparatus for explosive gas atmospheres. Part 14. Electrical installations in hazardous areas (other than mines)

ICS
29.160.20
CCS
发布
2006
实施
2007-01-01

Contains requirements for all types of 50 and 60 Hz cylinderical rotor synchronous generators rated 10 MVA and above.

Standard for Cylindrical-Rotor 50 and 60 Hz, Synchronous Generators Rated 10 MVA and Above

ICS
29.160.20
CCS
K21
发布
2005-12-29
实施

本标准规定了汽轮发电机多种非正常运行和特殊运行方式的允许限值以及相关的维护与检修措施。 本标准适用于300MW及以上容量的汽轮发电机,其他容量机组可以参照执行。对已投入运行但不能完全满足本标准的发电机,可根据实际情况对不能满足的部分条文,参照本标准确定运行条件。

Guide for Abnormal and Special Operations and Maintenances of Large Turbo-Generators

ICS
29.160.20
CCS
K20;K54
发布
2005-11-28
实施
2006-06-01

Rotating electrical machines - Part 3 : specific requirements for cylindrical rotor synchronous machines.

ICS
29.160.20
CCS
K21
发布
2005-10-01
实施
2005-10-05

The requirements in this standard apply to all types of 50 Hz and 60 Hz salient-pole synchronous generators and generator/motors rated 5 MVA and above to be used for hydraulic turbine or hydraulic pump/turbine applications.

Cylindrical-rotor 50 Hz and 60 Hz synchronous generators rated 10 MVA and above

ICS
29.160.20
CCS
K21
发布
2005-09-22
实施