31.220.10 插头和插座装置、连接器 标准查询与下载



共找到 2360 条与 插头和插座装置、连接器 相关的标准,共 158

Connectors for electronic equipment - Tests and measurements - Part 29-100: Signal integrity tests up to 500 MHz on M12 style connectors - Tests 29a to 29g (IEC 60512-29-100:2015); German version EN 60512-29-100:2015

ICS
31.220.10
CCS
L23
发布
2016-03
实施

Connectors for printed boards with frequencies below 3 MHZ Part 11: Detailed specifications for coaxial connectors (free connectors and fixed connector dimensions)

ICS
31.220.10
CCS
L23
发布
2016-01-15
实施
2016-06-01

Sound system equipment. Part 11. Application of connectors for the interconnection of sound system components

ICS
31.220.10
CCS
发布
2016
实施
2017-11-01

5.1 This practice is based on the use of electrical resistance as an indicator of contact performance. This is the fundamental physical attribute that reflects the condition of the electrical contact interface(s) within a connection. For practical current-carrying electrical connections, resistance may be calculated from potential drop measurements, as described, for example, in Test Method B539 and B812. 5.2 This practice accommodates the use of multiple test methods, as may be required to predict performance in a given application. 5.3 This practice applies only to the performance of the current-carrying contact interface(s). It does not characterize the performance of insulating materials or other components of a complete connection system. 5.4 Specifiers may use the performance classification as a requirement for a given application. 5.5 Manufacturers may use the performance classification to reflect the relative quality of their products. 1.1 This practice provides a method of specifying performance requirements for (or reporting test results of) electrical contact and connection systems. Both conductor and connector system performance may be specified by this practice, separately or in combination. 1.2 This practice may be used for separable or permanent contacts employing metallic conducting components. 1.3 This practice is applicable to both signal and power applications. 1.4 This practice is intended to be used for specifying performance of connectors and connection systems that are marketed for general public and trade application, as for instance for use in building wiring, electronics, and vehicles. 1.5 This practice is not intended to be used to specifying the performance of connection systems for specialized applications, such as military, industrial, aircraft, power distribution, and medical apparatus. 1.6 This practice does not specify the sample preparation or test sequences required for determining contact performance. It is the responsibility of the user of this practice to determine the applied test sequence(s) appropriate for the application. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to become familiar with all hazards including those identified in the appropriate Safety Data Sheet (SDS) for this product/material as provide by the manufacturer, to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Practice for Contact Performance Classification of Electrical Connection Systems

ICS
31.220.10
CCS
L23
发布
2016
实施

Connectors. Safety requirements and tests

ICS
31.220.10
CCS
发布
2016
实施
2018-07-01

This part of IEC 60603 covers 8-way@ shielded@ free and fixed connectors@ references dimensional@ mechanical@ electrical and environmental characteristics and tests in IEC 60603-7@ and specifies electrical transmission requirements@ including power sum alien (exogenous) crosstalk@ for frequencies up to 2 000 MHz. These connectors are typically used as ??category 8.1?? connectors in ??class I?? cabling systems specified in ISO/IEC 11801. These connectors are intermateable and interoperable with other IEC 60603-7 series connectors as defined in Clause 2 of IEC 60603-7. These connectors are backward compatible with other IEC 60603-7 series connectors@ except IEC 60603-7-7 and IEC 60603-7-71 connectors. NOTE Transmission performance categories: in this IEC standard@ the term ??category??@ when used in reference to transmission performance@ refers to those categories defined by ISO/IEC 11801.

Connectors for electronic equipment - Part 7-81: Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 2 000 MHz

ICS
31.220.10
CCS
发布
2015-12-16
实施
2015-12-18

Connectors for electronic equipment - Product requirements - Part 4-116: Printed board connectors - Detail specification for a high-speed two-part connector with integrated shielding function

ICS
31.220.10
CCS
发布
2015-11-23
实施

Connectors for electronic equipment - Product requirements - Part 4-116: Printed board connectors - Detail specification for a high-speed two-part connector with integrated shielding function

ICS
31.220.10
CCS
发布
2015-11-23
实施

Connectors for electronic equipment -- Tests and measurements -- Part 13-1: Mechanical operation tests -- Test 13a: Engaging and separating forces

ICS
31.220.10
CCS
L23
发布
2015-11-20
实施

Connectors for electronic equipment -- Product requirements -- Part 1: Generic specification

ICS
31.220.10
CCS
L23
发布
2015-11-20
实施

This International Standard establishes specifications and test requirements for a high-speed two-part connector with integrated shielding function for use as a printed board connector in industrial environments. The connectors connect a backplane to printed boards.

Connectors for electronic equipment - Product requirements - Part 4-116: Printed board connectors - Detail specification for a high-speed two-part connector with integrated shielding function

ICS
31.220.10
CCS
L23
发布
2015-11
实施

IEC 60512-29-100:2015 specifies the test methods for transmission performance for M12-style connectors up to 500 MHz. It is also suitable for testing lower frequency connectors if they meet the requirements of the detail specifications and of this standard. The test methods provided herein are: - insertion loss, test 29a; - return loss, test 29b; - near-end crosstalk (NEXT) test 29c; - far-end crosstalk (FEXT), test 29d; - transverse conversion loss (TCL), test 29f; - transverse conversion transfer loss (TCTL), test 29g. For the transfer impedance (ZT) test, see IEC 60512-26-100, test 26e. For the coupling attenuation see ISO/IEC 11801. All test methods apply for two and four pair connectors. Key words: Connectors, Signal Integrity, M12 Style Connector

Connectors for electronic equipment - Tests and measurements - Part 29-100: Signal integrity tests up to 500 MHz on M12 style connectors - Tests 29a to 29g

ICS
31.220.10
CCS
发布
2015-09-18
实施
2015-12-18 (7)

This part of IEC 60512, when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this part of IEC 60512 is to detail a standard test method to determine the tensile strength of a crimped connection.

Connectors for electronic equipment - Tests and measurements - Part 16-4: Mechanical tests on contacts and terminations - Test 16d: Tensile strength (crimped connections)

ICS
31.220.10
CCS
发布
2015-09-03
实施

This part of IEC 60512 applies to interconnect assemblies, such as electrical connectors, sockets and cable assemblies. This standard describes test procedures for measuring the magnitude of the electric and magnetic coupling between driven and quiet lines of an interconnect assembly. Both time domain (method A) and frequency domain methods (method B) for single-ended and differential transmission are described. Insertion and reference fixture techniques are also described.

Connectors for electronic equipment - Tests and measurements - Part 25-1: Test 25a - Crosstalk ratio

ICS
31.220.10
CCS
发布
2015-09-03
实施

This part of IEC 60512, when required by the detail specification, is used for testing electomechanical components within the scope of IEC technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this part of IEC 60512 is to detail a standard test method to determine the ability of a fixed male tab and its fixing to withstand a specified torque. If so specified in the detail specification, forces other than torsional may be applied.

Connectors for electronic equipment - Tests and measurements - Part 16-16: Mechanical tests on contacts and terminations - Test 16p: Torsional strength, fixed male tabs

ICS
31.220.10
CCS
发布
2015-09-03
实施

This part of IEC 60603 covers 8-way, shielded, free and fixed connectors, references dimensional, mechanical, electrical and environmental characteristics and tests in IEC 60603-7 and IEC 60603-7-1, and specifies electrical transmission requirements for frequencies up to 600 MHz. These connectors are typically used as category 7 connectors in class F cabling systems specified in ISO/IEC 11801. These connectors are intermateable and interoperable with other IEC 60603-7 series connectors as defined in Clause 2 of IEC 60603-7-1,

Connectors for electronic equipment - Part 7-7: Detail specification for 8-way, shielded, free and fixed connectors for data transmission with frequencies up to 600 MHz

ICS
31.220.10
CCS
发布
2015-09-03
实施

This part of IEC 61076 covers rectangular protective housings with push-pull coupling for upgrading existing 8-way shielded and unshielded connectors utilizing the interface described in IEC 60603-7-2, IEC 60603-7-3, IEC 60603-7-4, IEC 60603-7-41, IEC 60603-7-5, IEC 60603-7-51, IEC 60603-7-7 and IEC 60603-7-71 to IP65 and IP67 ratings according to IEC 60529, for use in industrial environments. Common mating configurations for all variants of the 8-way shielded and unshielded connectors are defined in IEC 60603-7. The mating dimensions for the housings under Clause 3 allow the mating conditions under IEC 60603-7 to be fulfilled. This standard covers a further variant of IEC 61076-3-106 housing known as variant 14. The fully assembled variant 14 connectors described in this document incorporate fixed and free connectors which are fully compliant which the relevant part of IEC 60603-7.

Connectors for electronic equipment - Product requirements - Part 3-117: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for industrial environments incorporating the IEC 60603-7

ICS
31.220.10
CCS
发布
2015-09-03
实施

This part of IEC 60512, when required by the detail specification, is used for testing connectors within the scope of IEC technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this part of IEC 60512 is to define a standard test method to assess the ability of the terminations of a connector to remain covered with solder when being brought into contact with molten solder under specified conditions.

Connectors for electronic equipment - Tests and measurements - Part 12-3: Soldering tests - Test 12c: Solderability, de-wetting

ICS
31.220.10
CCS
发布
2015-09-03
实施

This part of IEC 60512 is applicable to electrical connectors, sockets, cable assemblies or interconnection systems. This standard describes a frequency and a time domain method to measure attenuation/ insertion loss as a function of frequency. NOTE “Attenuation” is referenced throughout the document. Test professionals must use the appropriate term (attenuation or insertion loss) when summarizing and reporting the test measurements according to the type of specimen and transmission line being measured.

Connectors for electronic equipment - Tests and measurements - Part 25-2: Test 25b - Attenuation (insertion loss)

ICS
31.220.10
CCS
发布
2015-09-03
实施

This part of IEC 60512, when required by the detail specification, is used for testing electromechanical components within the scope of IEC technical committee 48. This test may also be used for similar devices when specified in a detail specification. The object of this test is to detail a standard test method to assess the ability of a component to carry its specified current, at room temperature, without exceeding a specified temperature rise.

Connectors for electronic equipment - Tests and measurements - Part 5-1: Current-carrying capacity tests - Test 5a: Temperature rise

ICS
31.220.10
CCS
发布
2015-09-03
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号