This part of IEC 61076 covers 10-way@ shielded@ free and fixed rectangular connectors for data transmission with frequencies up to 500 MHz and specifies the common dimensions@ mechanical@ electrical and transmission characteristics and environmental requirements as well as test specifications respectively. Connectors covered in this document are provided in three codings that differ only for the position of the polarization key and keyway@ in view of their differently intended use: ? Connectors Type A and C are intended for 10/100 Mbit/s as well as for 1/ 2@5 / 5 /10 Gbit/s Ethernet communication. ? Connectors Type B are intended for all other non-Ethernet applications such as signalling@ serial or other industrial bus communication systems. A-coding: The 45??ut corner used as polarization key and keyway system is located on the lower left corner of the male fixed connector (viewed from mating face) (Figures 5a@ 5b). B-coding: The 45??ut corner is located on the upper left corner of the male fixed connector (Figures 5c@ 5d). C-coding: There are two 45??orners located at the upper left and lower left corner (Figures 5e@ 5f). In this document@ the three codings@ A@ B@ and C are designated as ??Type A??@ ??Type B?? and ??Type C

Connectors for electrical and electronic equipment - Product requirements – Part 3-124: Rectangular connectors – Detail specification for 10-way, shielded, free and fixed connectors for I/O and data t

ICS
31.220.10
CCS
发布
2019-03-11
实施
2019-03-13

This part of IEC 60512 is used for testing connectors within the scope of SC 48B that are used in twisted pair communication cabling with remote power@ such as ISO/IEC 11801 Class D (or better)@ balanced cabling in support of IEEE Std 802.3bt?@ (PoE Plus ?C Power over Ethernet Plus). The object of this document is to detail a test schedule to determine the ability of pairs of connectors to withstand a sequence of tests with a total of 100 engagements and separations. The electrical current is passed through the connectors during the separation (unmating) step only@ in accordance with IEC 60512-9-3.

Connectors for electrical and electronic equipment - Tests and measurements - Part 99-002: Endurance test schedules - Test 99b: Test schedule for unmating under electrical load

ICS
31.220.10
CCS
发布
2019-03-08
实施
2019-03-12

Connectors for electronic equipment - Product requirements - Part 1: Generic specification

ICS
31.220.10
CCS
发布
2019-01-11
实施

Amendment 1 - Connectors for electronic equipment - Product requirements - Part 1: Generic specification

ICS
31.220.10
CCS
发布
2019-01-11
实施

What is BS EN IEC 60512-1 about?    BS EN IEC 60512-1 is the first part of the IEC 60512 series of standards that are intended to be used as a basis for tests and measurements specifications for electrical connectors. BS EN IEC 60512-1 details the generic specification for connectors that ensure the safety of electrical appliances. BS EN IEC 60512-1 provides a description and the practice of the various phases of tests and measurements (preparation, tests and measurements, requirements, documentation), in addition to basic terms and definitions.    Who is BS EN IEC 60512-1 for?   BS EN IEC 60512-1 on connectors is useful for:  

Connectors for electrical and electronic equipment. Tests and measurements. Generic specification

ICS
31.220.10
CCS
发布
2018-12-31
实施
2018-12-31

IEC 60512-1:2018 is available as IEC 60512-1:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60512-1:2018 is intended to be used as a basis for tests and measurements specifications for electrical connectors. It provides guidance and reference for tests and measurements within the IEC 60512 series. It includes the description and the practice of the various phases of tests and measurements (preparation, tests and measurements, requirements, documentation), in addition to basic terms and definitions applicable to any part of the IEC 60512 series. This standard shall be used in conjunction with IEC 60512-1-101 and relevant part(s) of series IEC 60512. Part 60512-1-100 provides the list of the existing test and measuring methods published within series IEC 60512. Detail tests and measurements specifications are applicable to electrical connectors and their components (e.g. connector inserts, connector housings, locking mechanisms, contacts and terminations) within the scope of technical committee 48. They may also be used for similar devices when specified in a detail product specification. Detail tests and measurements specifications are used in conjunction with detail product specifications which prescribe the tests to be used, the required degree of severity for each of them and the permissible performance limits. The detail product specification also specifies the deviations in procedures, which may be required when applying a test to the type of connector or its component under consideration, and it further specifies any special procedures which may be required. This fifth edition cancels and replaces the fourth edition, published in 2001. It constitutes a technical revision. This edition includes the following main technical changes with respect to the previous edition: – in Clause 3, only terms relating to the testing are defined, and IEC 61076-1 is referred to for terms of connectors. – Clause 4 (Numbering of tests and measurement specification) is added. – Subclause 5.1.2 (Calibration) is added. – in Clause 6 (Test), test procedure follows IEC 60068-1. Key words: Connectors, Test Specification

Connectors for electrical and electronic equipment - Tests and measurements - Part 1: Generic specification

ICS
31.220.10
CCS
发布
2018-11-30
实施
2019-02-26 (7)

本标准规定了TJC201型绝缘位移阴接触件连接器的术语和定义、产品分类、基本要求、技术要求、试验方法、检验规则、标志、包装、运输、贮存及质量承诺。 本标准适用于计算机、打印机及其它电子设备用的TJC201型绝缘位移阴接触件连接器(以下简称“连接器”)。

TJC201 type insulation displacement female contact connector

ICS
31.220.10
CCS
C398
发布
2018-10-26
实施
2019-02-28

Connectors for electrical and electronic equipment - Tests and measurements - Part 1: Generic specification

ICS
31.220.10
CCS
发布
2018-10-22
实施

This part of IEC 60512 is intended to be used as a basis for tests and measurements specifications for electrical connectors. It provides guidance and reference for tests and measurements within the IEC 60512 series. It includes the description and the practice of the various phases of tests and measurements (preparation, tests and measurements, requirements, documentation), in addition to basic terms and definitions applicable to any part of the IEC 60512 series. This document is used in conjunction with IEC 60512-1-101 to establish uniform detail tests and measurements specifications. Detail tests and measurements specifications are applicable to electrical connectors and their components (e. g. connector inserts, connector housings, locking mechanisms, contacts and terminations) within the scope of technical committee 48. They may also be used for similar devices when specified in a detail product specification. Detail tests and measurements specifications are used in conjunction with detail product specifications which prescribe the tests to be used, the required degree of severity for each of them and the permissible performance limits. The detail product specification also specifies the deviations in procedures, which may be required when applying a test to the type of connector or its component under consideration, and it further specifies any special procedures which may be required. NOTE RF and fibre optical connectors are not dealt with by subcommittee 48B, however, hybrid connectors which additionally employ RF and/or fibre optic contacts, are handled by SC 48B in cooperation with TC 46 and/or TC 86.

Connectors for electrical and electronic equipment - Tests and measurements - Part 1: Generic specification

ICS
31.220.10
CCS
发布
2018-10-00
实施

This part of IEC 60512 covers additional, supplemental specifications for signal integrity and transmission performance test methods of IEC 60512-27-100, for connectors using de- embedded crosstalk measurements, which are specified in respective parts of IEC 60603-7 standards for connecting hardware applications up to 2000 MHz. These additional specifications are also applicable for testing the related lower frequency connectors. However, the test methodology specified in the detail specification for any given connector remains the reference conformance test for that connector. Test procedures of IEC 60512-27-100 affected by these supplemental methods and procedures are: insertion loss, test 27a; return loss, test 27b; near-end crosstalk (NEXT) test 27c; far-end crosstalk (FEXT), test 27d; transverse conversion loss (TCL), test 27f; transverse conversion transfer loss (TCTL), test 27g. Other test procedures referenced here are; transfer impedance (ZT), see test procedures in IEC 62153-4-6 or IEC 62153-4-7; for coupling attenuation (aC), see test procedures in IEC 62153-4-7 or IEC 62153-4-12.

Connectors for electrical and electronic equipment - Tests and measurements - Part 27-200: Additional specifications for signal integrity tests up to 2000 MHz on IEC 60603-7 series connectors - Tests 27a to 27g

ICS
31.220.10
CCS
发布
2018-10-00
实施

Connectors for electrical and electronic equipment - Part 01: Rectangular connectors - Detail specification for 8-way, shielded, free and fixed high density connectors for data transmission with frequ

ICS
31.220.10
CCS
发布
2018-05-24
实施

What is BS EN IEC 60512 ‑ 15 ‑ 2 - Connectors for electrical and electronic equipment about?    BS EN IEC 60512 is an international standard used for connectors for electrical and electronic equipment that specifies the measurement and test methods.  BS EN IEC 60512 ‑ 15 ‑ 2 is useful in conducting the connector testing used in electrical and electronic equipment. BS EN IEC 60512 ‑ 15 ...

Connectors for electrical and electronic equipment. Tests and measurements. Connector tests (mechanical). Test 15b: Insert retention in housing (axial)

ICS
31.220.10
CCS
发布
2018-04-30
实施
2018-04-30

This part of IEC 61076 covers 8-way, shielded, free and fixed rectangular connectors for I/O and Gigabit Ethernet applications, suitable for use in harsh environments, and is intended to specify the common dimensions, mechanical, electrical and environmental characteristics and tests for this family of connectors.

Connectors for electrical and electronic equipment - Product requirements - Part 3-122: Detail specification for 8-way, shielded, free and fixed connectors for I/O and Gigabit Ethernet applications in harsh environments (IEC 61076-3-122:2017); German vers

ICS
31.220.10
CCS
L23
发布
2018-04-01
实施
2018-04-01

IEC 60512-15-2:2018 This part of IEC 60512, when required by the detail (product) specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail (product) specification. The object of this document is to detail a standard test method to assess the effectiveness of the retaining system of a connector insert within a connector housing to withstand axial forces likely to be encountered during normal use, i.e. the highest insertion and withdrawal forces into/from a mating counterpart, without the connector insert being dislodged from the connector housing. The test method detailed in this document is a companion to the one detailed in IEC 60512-15-3 This second edition cancels and replaces the first edition, published in 2008. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: the test method B (pressure method) suitable for testing hermetic connector has been added. This edition reflects IEC 60512-1-101, Blank detail specification.

Connectors for electrical and electronic equipment - Tests and measurements - Part 15-2: Connector tests (mechanical) - Test 15b: Insert retention in housing (axial)

ICS
31.220.10
CCS
发布
2018-03-23
实施
2018-05-16 (7)

一、电气特性 1.产品的每一线的导通阻抗应不大于10Ω。各个非导通端子之间不应有短路现象。 2.产品的绝缘电阻应不小于1MΩ。 3.产品承受100V直流电60s,不应有放电、击穿、飞弧等现象,产品不应损坏。 4.漏电电流不应超过1.0mA等。 二、机械特性 1.USB接口完全插入所需的力应不大于35N。 2.USB接口完全拔出所需的力应不小于10N等。

USB2.0 interface conversion cable

ICS
31.220.10
CCS
C383
发布
2018-01-31
实施
2018-02-06

This part of IEC 60512@ when required by the detail (product) specification@ is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail (product) specification. The object of this document is to detail a standard test method to assess the effectiveness of the retaining system of a connector insert within a connector housing to withstand axial forces likely to be encountered during normal use@ i.e. the highest insertion and withdrawal forces into/from a mating counterpart@ without the connector insert being dislodged from the connector housing. NOTE The test method detailed in this document is a companion to the one detailed in IEC 60512-15-3 (see Bibliography).

Connectors for electrical and electronic equipment - Tests and measurements - Part 15-2: Connector tests (mechanical) - Test 15b: Insert retention in housing (axial)

ICS
31.220.10
CCS
发布
2018-01-12
实施
2018-01-17

This document covers rectangular IP65/IP67 connectors with 5 poles for electric power supply up to 16 A. These connectors consist of fixed and free connectors, either rewirable or non- rewirable (for both portions). It uses the general function principles of the push-pull connector housing system described in IEC 61076-3-117 with IP65/IP67 degree of protection according to IEC 60529 for harsh applications. Male connectors have 5 square 1 mm electric contacts, with 16 A rated current. Connectors according this document are without breaking capacity COC according to IEC 61984, therefore they are not intended to be engaged or disengaged in normal use when live or under load, if not otherwise specified by the manufacturer.

Connectors for electrical and electronic equipment - Product requirements - Part 3-126: Rectangular connectors - Detail specification for 5 pole power connectors for industrial environments with push-pull locking

ICS
31.220.10
CCS
发布
2018-01-01
实施

This part of IEC 61076-2 specifies 4 to 6-way circular connectors with M12 screw-locking with current ratings up to 16 A and voltage ratings of 63 V or 630 V@ that are typically used for power supply and power applications in industrial premises. These connectors consist of both fixed and free connectors either rewireable or non-rewireable@ with M12 screw-locking. Male connectors have round contacts ?1@0 mm and ?1@5 mm. The different codings provided by this document prevent the mating of accordingly coded male or female connectors to any other similarly sized interfaces@ covered by other standards and the cross-mating between the different codings provided by this document. NOTE M12 is the dimension of the thread of the screw-locking mechanism of these circular connectors.

Connectors for electrical and electronic equipment - Product requirements - Part 2-111: Circular connectors - Detail specification for power connectors with M12 screw-locking

ICS
31.220.10
CCS
发布
2017-12-07
实施
2017-12-09

This part of IEC 61076-3 establishes specifications and test requirements for 10-way shielded and unshielded rectangular, free and fixed connectors, with push-pull coupling, for data transmission with frequencies up to 100 MHz and for use in industrial environments. This document specifies free and fixed connectors with round contacts, suitable for screw or crimp terminations. Other terminations techniques, such as solder or printed board connections are upon agreement between manufacturer and user. The free and fixed connectors have a push-pull locking mechanism for IP65 and IP67 protection according to IEC 60529. Connectors according this document are without breaking capacity COC according to 3.9 of IEC 61984:2008, therefore they are not intended to be engaged or disengaged in normal use when live or under load, if not otherwise specified by the manufacturer.

Connectors for electrical and electronic equipment - Product requirements - Part 3-119: Rectangular connectors - Detail specification for shielded and unshielded, free and fixed 10-way connectors with push-pull coupling for industrial environments for dat

ICS
31.220.10
CCS
L23
发布
2017-12-00
实施
2017-12-12

What is BS EN 61076-2-113 – Circular connectors about ? BS EN 61076-2-113 is the second part of an international standard used for connectors that specifies the test methods and characteristics of the circular connectors. BS EN 61076-2-113 describes M12 circular connectors with two data pairs and power contacts with current ratings up to 12 A, that are typically used for data and power applications in industrial premises. These connectors consist of both fixed and free connectors either rewireable or non-rewireable, with screw-locking. Male connectors have round contacts diameters of 1,50 mm, 1,00 mm and 0,60 mm.   The different codings provided by BS EN 61076-2-113 prevent the mating of accordingly coded   male or female connectors to any other similarly sized interfaces covered by other standards   and the cross-mating between the different cod...