J99 其他动力设备 标准查询与下载



共找到 121 条与 其他动力设备 相关的标准,共 9

この規格は,灯油,軽油又は重油を燃料とする石油燃焼機器とJIS S 3020(石油燃焼機器用油タンク)(以下,油タンクという。).JIS S 3026(石油燃焼機器用灯油供給器)(以下,供給器という。)等とを接続し。燃料供給に用いる銅製送油管(以下,送油管という。)について規定する。

Oil discharge copper pipe for oil burning appliances

ICS
27.060.10
CCS
J99
发布
2006-03-25
实施

? ??? ?? ????? ????? ? ???? ?? ???? ?? ???? ???? ?

Gas volume meters-Part 1:General provisions

ICS
17.060
CCS
J99
发布
2005-12-22
实施
2005-12-22

? ??? ?????? ?? ??? ???? ?? ???? ?? ???? ?? ??? ??

Heat meters-Part 1:General requirements

ICS
17.060
CCS
J99
发布
2005-12-22
实施
2005-12-22

이 규격은 주차 구획이 2단으로 배치되어 있고 출입구가 있는 단의 모든 주차 구획을 주차설

2story type parking facility for automobile

ICS
91.09
CCS
J99
发布
2005-12-22
实施
2005-12-22

? ??? ?? ??? ???? ? ?? ??? ??? ??? ???? ?? ?? ???

Hot water meters

ICS
17.060
CCS
J99
发布
2005-12-22
实施
2005-12-22

??? ? KS B 50075-1? ?? ?? ??? ???? ???? ? ???? ???

Heat meters-Part 2:Test methods

ICS
17.200.10
CCS
J99
发布
2005-12-22
实施
2005-12-22

? ??? ?? ?? ??? ??? ????? ??, ?????? ???(measuring

Gas volume meters-Part 2:Diaphragm type gas meter

ICS
17.060
CCS
J99
发布
2005-12-22
实施
2005-12-22

? ??? ??? ?? ????? ??? ????. 1.1 ???? ???? ??? ?

Gas volume meters-Part 3:Rotary pistongas meters and turbine gas meters

ICS
17.060
CCS
J99
发布
2005-12-22
实施
2005-12-22

1.1 This European Standard applies to electrical or non-electrical temperature control devices which are used to control temperatures within heat generating systems by controlling the supply of energy; it also applies to limiting devices which ensure that the temperature in heat generating systems will not exceed a predefined limit. This European Standard requires operating values, operating times, and operational sequences associated with the safety of the heat generating system. This European Standard also applies to controls using NTCs or PTCs thermistors, additional requirements for which are contained in Annex J of EN 60730-2-9. This European Standard applies to controls with a rated voltage not exceeding 690 V and with a rated current r~ot exceeding 63 A. This European Standard also applies to manual controls if, electrically and/or mechanically, they form an integral part of automatic controls. NOTE Requirements for manually operated switches not forming part of an automatic control are contained in EN 61058-1. This European Standard does not apply to room thermostats. 1.2 This European Standard does not take into account the response value of an automatic action of the control, if such a response value is dependent upon the method of mounting the control in the heat generating system or equipment, in which case the control should be tested together with the heat generator. Where a response value is of significance for the protection of the user, or surroundings, the value defined in the appropriate household equipment standard or as determined by the manufacturer applies. 1.3 This European Standard applies also to controls incorporating electronic devices, requirements for which are contained in Annex DX.

Temperature control devices and temperature limiters for heat generating systems; English version of DIN EN 14597:2005

ICS
17.200.20;97.120
CCS
J99
发布
2005-12
实施

This document specifies the requirements, operating conditions and test methods for burner control systems for automatic and semi-automatic oil burners with or without fans. It also applies to dual fuel burners, for use with either oil or gaseous fuels, when operating on oil. This document covers type testing only. This document also applies to automatic burner control systems, programming units or flame detector devices that include additional functions. Automatic burner control systems utilising thermo-electric flame supervision devices are not covered by this document.

Automatic burner control systems for oil burners

ICS
27.060.10
CCS
J99
发布
2005-06-30
实施
2005-06-30

Details test and examination of criteria for direct gas-fired industrial air heaters of the non-recirculating type, for use with nat., mfd. and mixed gases, LP gases, and LP gas-air mixtures. A direct gas-fired industrial air heater of the non-recirculat

Non-Recirculating Direct Gas Fired Industrial Air Heaters

ICS
91.140.30
CCS
J99
发布
2005
实施

Specification of steam turbine for power plant

ICS
27.100
CCS
J99
发布
2004-10-20
实施
2005-04-01

This European Standard specifies the terminology, the general requirements for the construction and operation of automatic forced draught gas burners and also the provision of control and safety devices, and the type test procedure for these burners. This standard is applicable to — automatic gas burners with a combustion air fan (hereinafter called "burners") that are equipped as described in clause 4, intended for use in heat generators of different types, and that are operated with fuel gases; — total pre-mixed burners and nozzle mixed burners. The standard is applicable to — single burners with a single combustion chamber, although such burners are fitted to a single appliance, in which case the requirements of the relevant appliance standard shall additionally apply; — single-fuel and dual-fuel burners when operating only on gas; — the gas function of dual-fuel burners designed to operate simultaneously on gaseous and liquid fuels in which case the requirements of EN 267 will also apply in respect of the liquid fuel function.

Automatic forced draught burners for gaseous fuels

ICS
27.060.20
CCS
J99
发布
2003-10-03
实施
2003-10-03

Independent gas-fired convection heaters; Amendment A1; German version EN 613:2000/A1:2003

ICS
97.100.20
CCS
J99
发布
2003-09
实施
2003-09-01

이 규격은 건설 기계에 적용되는 좌석 및 좌석 부착 장치의 제반 요구 조건에 대해 규정

Seat for construction machinery

ICS
53.100
CCS
J99
发布
2003-07-07
实施
2003-07-07

This guide can be used by code officials, architects, and other interested parties to evaluate the design and construction of masonry heaters. It is not restricted to a specific method of construction, nor does it provide all specific details of construction of a masonry heater. This guide does provide the principles to be followed for the safe construction of masonry heaters. This guide is not intended as a complete set of directions for construction of masonry heaters. Construction of masonry heaters is complex, and in order to ensure their safety and performance, construction shall be done by or under the supervision of a skilled and experienced masonry heater builder. 1.1 This guide covers the design and construction of solid fuel burning masonry heaters. It provides dimensions for site constructed masonry heater components and clearances that have been derived by experience and found to be consistent with the safe installation of those masonry heaters. 1.2 Values given in SI units are to be regarded as standard. Inch/pound units may be rounded (see ). All dimensions are nominal unless specifically stated otherwise. All clearances listed in this guide are actual dimensions. 1.3 This guide applies to the design and construction of masonry heaters built on-site with the components and materials specified herein. It does not apply to the construction/installation requirements for component systems that have been safety tested and listed. The requirements for listed masonry heater systems are specified in the manufacturer''s installation instructions. 1.4 The design and construction of solid fuel burning masonry heaters shall comply with applicable building codes.

Standard Guide for Construction of Solid Fuel Burning Masonry Heaters

ICS
25.180.20
CCS
J99
发布
2003
实施

This guide can be used by code officials, architects, and other interested parties to evaluate the design and construction of masonry heaters. It is not restricted to a specific method of construction, nor does it provide all specific details of construction of a masonry heater. This guide does provide the principles to be followed for the safe construction of masonry heaters. This guide is not intended as a complete set of directions for construction of masonry heaters. Construction of masonry heaters is complex, and in order to ensure their safety and performance, construction shall be done by or under the supervision of a skilled and experienced masonry heater builder.4 1.1 This guide covers the design and construction of solid fuel burning masonry heaters. It provides dimensions for site constructed masonry heater components and clearances that have been derived by experience and found to be consistent with the safe installation of those masonry heaters.1.2 Values given in SI units are to be regarded as standard. Inch/pound units may be rounded (see IEEE/ASTM SI-10). All dimensions are nominal unless specifically stated otherwise. All clearances listed in this guide are actual dimensions.1.3 This guide applies to the design and construction of masonry heaters built on-site with the components and materials specified herein. It does not apply to the construction/installation requirements for component systems that have been safety tested and listed. The requirements for listed masonry heater systems are specified in the manufacturer''s installation instructions.1.4 The design and construction of solid fuel burning masonry heaters shall comply with applicable building codes.

Standard Guide for Construction of Solid Fuel Burning Masonry Heaters

ICS
25.180.20 (Fuel furnaces)
CCS
J99
发布
2003
实施

本标准规定了农村家用省柴灶的设计、施工、测试、使用的技术原则。本标准适用于农村家用省柴灶的设计、施工、性能测试和使用管理。

Rural Household Firewood Saving Stoves Technical Regulations

ICS
27.060
CCS
J99
发布
2002-09-30
实施
2002-10-10

This Code defines procedures for field performance and acceptance testing of hydraulic turbines and pump-turbines operating with water in either the turbine or pump mode. This Code applies to all sizes and types of hydraulic turbines or pump-turbines. It defines methods for ascertaining performance by measuring flow rate (discharge), head, and power, from which efficiency may be determined. Requirements are included for pretest arrangements, types of instrumentation, methods of measurement, testing procedures, methods of calculation, and contents of test reports. This Code contains mandatory test requirements and various methods of measurement. Where multiple methods of measurement and procedures are permitted by the Code, prior written agreement as to the selected methods and procedures is required. The test procedures specified herein and the limitations placed on measurement methods and instrumentation are capable of providing a total uncertainty, calculated in accordance with the procedures of PTC 19.1 and of this Code, of not more than: (a) Power ?.2%, (b) Flow Rate ?.5%, and (c) Efficiency ?.0%. Where favorable measurement conditions exist and best methods can be used, smaller uncertainties should result. Any test with uncertainties greater than the above shall not qualify as an ASME Code test. This Code contains recommended procedures for index testing and describes the purposes for which index tests may be used. This Code also contains Tables for (a) Acceleration of gravity as a function of latitude and altitude; (b) Vapor pressure of distilled water as a function of latitude and altitude; (c) Density of water at a given temperature and pressure; (e) Density of dry air; and (f) Density of mercury.

Hydraulic Turbines and Pump-Turbines Consolidation of ASME PTC 18-1992 and ASME PTC 18.1-1978

ICS
27.140
CCS
J99
发布
2002-01-01
实施

The document specifies the requirements for the ventilation of non-domestic premises where gas-fired radiant heaters complying with EN 416-1:1999 or EN 419-1:1999 are installed and operated. The document is applicable to type A appliances (see 3.2).

Gas-fired overhead radiant heaters - Ventilation requirements for non-domestic premises; German version EN 13410:2001

ICS
91.140.30;97.100.20
CCS
J99
发布
2002-01
实施
2002-01-01



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved