K11 裸电线 标准查询与下载



共找到 506 条与 裸电线 相关的标准,共 34

1.1 This specification covers bare concentric-lay-stranded conductors made from bare round copper-clad steel wires for general use for electrical purposes. 1.2 For the purpose of this specification, conductors are classified as follows: Grade 40 HS, Grade 30 HS, and Grade 30 EHS. 1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.

Standard Specification for Concentric-Lay-Stranded Copper-Clad Steel Conductors

ICS
29.060.20 (Cables)
CCS
K11
发布
2004
实施

1.1 This specification covers bare round copper-clad aluminum wire for electrical applications.1.2 Four classes of copper-clad aluminum wire are covered as follows:Class 10A8212;Nominal 10 volume % copper, annealed.Class 15A8212;Nominal 15 volume % copper, annealed.Class 10H8212;Nominal 10 volume % copper, hard-drawn.Class 15H8212;Nominal 15 volume % copper, hard-drawn.1.3 The values stated in inch-pound units are to be regarded as the standard, except for resistivity and density, where the SI units are the standard. The values given in parentheses are for information only.

Standard Specification for Copper-Clad Aluminum Wire

ICS
29.060.10 (Wires)
CCS
K11
发布
2004
实施

1.1 This specification covers bare round copper-clad aluminum wire for electrical applications.1.2 Four classes of copper-clad aluminum wire are covered as follows:Class 10A8212;Nominal 10 volume % copper, annealed.Class 15A8212;Nominal 15 volume % copper, annealed.Class 10H8212;Nominal 10 volume % copper, hard-drawn.Class 15H8212;Nominal 15 volume % copper, hard-drawn.1.3 The values stated in inch-pound units are to be regarded as the standard, except for resistivity and density, where the SI units are the standard. The values given in parentheses are for information only.

Standard Specification for Copper-Clad Aluminum Wire

ICS
29.060.10 (Wires)
CCS
K11
发布
2004
实施

This test method is designed as an inspection or acceptance test of new bare soft square and rectangular wire intended for subsequent fabrication into magnet wire. Note 18212;Since the applied unit stress and the time of application are constant for all wire sizes, the test enables comparisons of stiffness to be made between wires of the same or different size on the basis of the permanent elongation resulting from the application of a low unit stress.1.1 This test method, known as the low-stress elongation (LSE) test, covers the procedure for determining the stiffness of bare soft square and rectangular copper and aluminum wire in terms of the permanent elongation resulting from the application of a tensile stress.1.2 The SI values for the mass of the specimen are regarded as the standard. For all other properties, the inch-pound values are to be regarded as standard and the SI units may be approximate.

Standard Test Method for Stiffness of Bare Soft Square and Rectangular Copper and Aluminum Wire for Magnet Wire Fabrication

ICS
29.060.10
CCS
K11
发布
2004
实施

1.1 This specification covers aluminum 1350-H19 (extra hard), 1350-H16 or -H26 (3/4 hard), 1350-H14 or -H24 (1/2 hard), and 1350-H142 or -H242 (1/2 hard), bare concentric-lay-stranded conductors constructed with a straight round central wire surrounded by one or more layers of helically layed wires. The conductors are for general use for electrical purposes (Explanatory and Note 0).1.2 The values stated in inch-pound or SI units are to be regarded separately as standard. The values in each system are not exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification.1.2.1 For density, resistivity and temperature, the values stated in SI units are to be regarded as standard.Note 2Prior to 1975, aluminum 1350 was designated as EC aluminum.Note 3The aluminum and temper designations conform to ANSI Standard H35.1/H35.1M. Aluminum 1350 corresponds to Unified Numbering System A91350 in accordance with Practice E 527.Note 4Sealed conductors that are intended to prevent longitudinal water propagation and are further covered/insulated are also permitted within the guidelines of this specification.

Standard Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors

ICS
CCS
K11
发布
2004
实施

1.1 This specification covers stranded conductors made from round copper wires, either uncoated or coated with tin, lead, or lead alloy for general use in insulated conductor assemblies for electrical purposes. These conductors shall be composed of one or more roller shaped or die closed layers of helically laid wires using the single input wire (SIW) methodology. (see Note 1 and Explanatory Note 1)Note 1Sealed conductors which are intended to prevent longitudinal water propagation and are further covered/insulated, are also permitted within the guidelines of this specification.1.2 The values stated in inch-pound or SI units are to be regarded separately as standard. The values in each system are not exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification.1.2.1 For density, resistivity, and temperature, the values stated in SI units are to be regarded as standard.

Standard Specification for Compressed Round Stranded Copper Conductors, Hard, Medium-Hard, or Soft Using Single Input Wire Construction

ICS
29.060.10 (Wires)
CCS
K11
发布
2004
实施

1.1 This specification covers stranded conductors made from round copper wires, either uncoated or coated with tin, lead, or lead alloy for general use in insulated conductor assemblies for electrical purposes. These conductors shall be composed of one or more roller shaped or die closed layers of helically laid wires using the single input wire (SIW) methodology. (see Note 1 and Explanatory Note 1)Note 1Sealed conductors which are intended to prevent longitudinal water propagation and are further covered/insulated, are also permitted within the guidelines of this specification.1.2 The values stated in inch-pound or SI units are to be regarded separately as standard. The values in each system are not exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification.1.2.1 For density, resistivity, and temperature, the values stated in SI units are to be regarded as standard.

Standard Specification for Compressed Round Stranded Copper Conductors, Hard, Medium-Hard, or Soft Using Single Input Wire Construction

ICS
29.060.10 (Wires)
CCS
K11
发布
2004
实施

1.1 This specification covers compact round concentric-lay-stranded conductors made from aluminum 1350-H19 (extra hard) wires and round zinc-coated, aluminum-coated, or aluminum-clad steel core wires usually used in overhead lines. These conductors shall be constructed with one steel core wire surrounded by one or more layers of helically-laid compacted or otherwise shaped aluminum wires (Explanatory Note 1 and Note 2).1.2 Compact ACSR covered by this specification has five types of steel core wire which are designated by abbreviations as follows (Explanatory NOTE 2).1.2.1 ACSR/GA/COMPCompact ACSR using Class A zinc-coated steel wire,1.2.2 ACSR/GB/COMPCompact ACSR using Class B zinc-coated steel wire,1.2.3 ACSR/GC/COMPCompact ACSR using Class C zinc-coated steel wire,1.2.4 ACSR/AZ/COMPCompact ACSR using aluminum-coated (aluminized) steel wire, and1.2.5 ACSR/AW/COMPCompact ACSR using aluminum-clad steel wire.1.3 The SI values of density and resistivity are to be regarded as standard. For all other properties the inch-pound values are to be regarded as standard and the SI units may be approximate. Note 18212;Prior to 1975, aluminum 1350 was designated as EC aluminum.Note 28212;The aluminum and temper designations conform to ANSI H35.1. Aluminum 1350 corresponds to Unified Numbering System A91350 in accordance with Practice E 527.

Standard Specification for Compact Round Concentric-Lay-Stranded Aluminum Conductors, Steel-Reinforced (ACSR/COMP)

ICS
CCS
K11
发布
2004
实施

1.1 This specification covers 21 % conductivity hard-drawn round copper-clad steel wire for coaxial cable center conductors (Note 1). Note 18212;Wire ordered to this specification is not intended for redrawing since it is furnished in the hard-drawn temper. If wire is desired for the purpose, the manufacturer should be consulted.1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.

Standard Specification for Copper-Clad Steel Electrical Conductor for CATV Drop Wire

ICS
29.060.10 (Wires)
CCS
K11
发布
2004
实施

1.1 This specification covers concentric-lay-stranded conductors made from round aluminum 1350-H19 (extra hard) aluminum wires and round aluminum-clad steel core wires for use as overhead electrical conductors (Explanatory Note 1 and Note 2). 1.2 The SI values of density and resistivity are to be regarded as standard. For all other properties the inch-pound units are regarded as standard and the SI units may be approximate.

Standard Specification for Concentric-Lay-Stranded Aluminum Conductors, Aluminum-Clad Steel Reinforced (ACSR/AW)

ICS
29.240.20 (Power transmission and distribution lin
CCS
K11
发布
2004
实施

1.1 This specification covers bare concentric-lay-stranded conductors made from round copper wires, either uncoated or coated with tin, lead, or lead alloy for general use for electrical purposes. These conductors shall be constructed with a central core surrounded by one or more layers of helically laid wires. Note 1This specification also permits conductors for use as covered or insulated electrical conductors.Note 2Sealed conductors, that are intended to prevent longitudinal water propagation and are further covered/insulated, are also permitted within the guidelines of this specification.1.2 For the purposes of this specification, conductors are classified as follows (Explanatory NOTE 1 and NOTE 2):1.2.1 Class AAFor bare conductors usually used in overhead lines.1.2.2 Class AFor conductors to be covered with weather-resistant (weather-proof), slow-burning materials, and for bare conductors where greater flexibility than is afforded by Class AA is required.1.2.3 Class BFor conductors to be insulated with various materials such as rubber, paper, varnished cloth, and so forth, and for the conductors indicated under Class A where greater flexibility is required.1.2.4 Class C and Class DFor conductors where greater flexibility is required than is provided by Class B conductors.1.3 The SI values for density are regarded as the standard. For all other properties, the inch-pound values are to be regarded as standard and the SI units may be approximate.

Standard Specification for Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft

ICS
29.060.20 (Cables)
CCS
K11
发布
2004
实施

1.1 This specification covers bare compact round stranded conductors made from uncoated copper wires of a single input wire (SIW) diameter for general use in covered or insulated electrical wires or cables. These conductors shall be constructed with one or more layers of helically laid compacted wires (Explanatory Note 1, Note 2, and Note 3).1.2 The values stated in inch-pound or SI units are to be regarded separately as standard. The values in each system are not exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification.1.2.1 For density, resistivity and temperature, the values stated in SI units are to be regarded as standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Compact Round Stranded Copper Conductors Using Single Input Wire Construction

ICS
CCS
K11
发布
2004
实施

1.1 This specification covers aluminum 1350-H19 (extra hard), 1350-H16 or -H26 (3/4 hard), 1350-H14 or -H24 (1/2 hard), 1350-H142 or -H242 (1/2 hard), and aluminum alloy 8XXX series as listed in Specification B 800 for tempers "O" and H1X or H2X, bare stranded conductors composed of one or more roller shaped or die compressed layers of helically layed wires. The conductors are for general use for electrical purposes (Explanatory Notes 1 and 2).Note 1For the purposes of this specification, single input wire (SIW) construction is defined as follows: a stranded conductor design methodology that varies the number of wires within a range of conductor sizes in order to permit that range of conductor sizes to be constructed from a single wire size.1.2 The values stated in inch-pound or SI units are to be regarded separately as standard. The values in each system are not exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification.1.2.1 For density, resistivity, and temperature, the values stated in SI units are to be regarded as standard.Note 2Prior to 1975, aluminum 1350 was designated as EC aluminum.Note 3The aluminum and temper designations conform to ANSI H35.1. Aluminum 1350 corresponds to Unified Numbering System A91350 in accordance with Practice E 527. Aluminum alloys in the 8000 series correspond to Unified Numbering System A98XXX in accordance with Practice E 527.Note 4This specification also permits conductors for use as covered or insulated electrical conductors.Note 5Sealed conductors, which are intended to prevent longitudinal water propagation and are further covered/insulated, are also permitted within the guidelines of this specification.

Standard Specification for Compressed Round Stranded Aluminum Conductors Using Single Input Wire Construction

ICS
29.240.20 (Power transmission and distribution lin
CCS
K11
发布
2004
实施

1.1 This specification covers aluminum 1350-H19 (extra hard), 1350-H16 or -H26 (¾ hard), 1350-H14 or -H24 (½ hard), 1350-H142 or -H242 (½ hard), and aluminum alloy 8XXX series as listed in Specification B800 for tempers “O” and H1X or H2X, bare stranded conductors composed of one or more roller shaped or die compressed layers of helically layed wires. The conductors are for general use for electrical purposes (Explanatory Notes 1 and 2). Note 18212;For the purposes of this specification, single input wire (SIW) construction is defined as follows: a stranded conductor design methodology that varies the number of wires within a range of conductor sizes in order to permit that range of conductor sizes to be constructed from a single wire size. 1.2 The SI values for resistivity are regarded as standard. For all other properties, the inch-pound units are regarded as standard and the SI units may be approximate. Note 28212;Prior to 1975, aluminum 1350 was designated as EC aluminum. Note 38212;The aluminum and temper designations conform to ANSI H35.1. Aluminum 1350 corresponds to Unified Numbering System A91350 in accordance with Practice E527. Aluminum alloys in the 8000 series correspond to Unified Numbering System A98XXX in accordance with Practice E527. Note 48212;This specification also permits conductors for use as covered or insulated electrical conductors. Note 58212;Sealed conductors, which are intended to prevent longitudinal water propagation and are further covered/insulated, are also permitted within the guidelines of this specification.

Standard Specification for Compressed Round Stranded Aluminum Conductors Using Single Input Wire Construction

ICS
29.240.20 (Power transmission and distribution lin
CCS
K11
发布
2004
实施

1.1 This specification covers aluminum 1350-H19 (extra hard), 1350-H16 or -H26 ([n ]hard), 1350-H14 or -H24 (1/2 hard) and 1350-H142 or -H242 (1/2 hard) bare compact-round concentric-lay-stranded conductors made from round or shaped wires for use as uninsulated electrical conductors or in covered or insulated electrical conductors. These conductors shall be composed of a central core surrounded by one or more roller or die compacted layers of helically applied wires (Explanatory Note 0 and ).1.2 The values stated in inch-pound or SI units are to be regarded separately as standard. Each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the specification. For conductor sizes designated by AWG or kcmil sizes, the requirements in SI units are numerically converted from the corresponding requirements in inch-pound units. For conductor sizes designation by AWG or kcmil, the requirements in SI units have been numerically converted from corresponding values stated or derived in inch-pound units. For conductor sizes designated by SI units only, the requirements are stated or derived in SI units.1.2.1 For density, resistivity and temperature, the values stated in SI units are to be regarded as standard. Note 1-Prior to 1975, aluminum 1350 was designated as EC aluminum.Note 2 - The aluminum and temper designations conform to ANSI Standard H35.1. Aluminum 1350 corresponds to Unified Numbering System A91350 in accordance with Practice E 527.

Standard Specification for Compact Round Concentric-Lay-Stranded Aluminum 1350 Conductors

ICS
29.240.20 (Power transmission and distribution lin
CCS
K11
发布
2004
实施

1.1 This specification covers bare round copper-clad aluminum wire for electrical applications. 1.2 Four classes of copper-clad aluminum wire are covered as follows: Class 10ANominal 10 volume % copper, annealed. Class 15ANominal 15 volume % copper, annealed. Class 10HNominal 10 volume % copper, hard-drawn. Class 15HNominal 15 volume % copper, hard-drawn. 1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3.1 Exception8212;The values stated in SI units for resistivity and density are to be regarded as standard.

Standard Specification for Copper-Clad Aluminum Wire

ICS
29.060.10 (Wires)
CCS
K11
发布
2004
实施

1.1 This specification covers cored, annular, concentric-lay-stranded conductors made from round soft copper wires, either uncoated or coated with tin for use as electrical conductors (Explanatory Note 1 and 2).1.2 The constructions prescribed herein are suitable for bare conductors, or for conductors to be covered with weather-resistant (weather-proof) material, or for conductors to be insulated with rubber, varnished cloth, or impregnated paper, except types such as "oil-filled" or "gas-filled" (Explanatory Note 3).1.3 Cored, annular conductor constructions not included in this specification shall be specifically agreed upon between the manufacturer and the purchaser when placing the order.1.4 These constructions are not recommended for use as electric furnace leads where great flexibility is required and special conductor designs are indicated in consideration of the particular service requirements.1.5 The SI values for density are regarded as the standard. For all other properties the inch-pound values are to be regarded as standard and the SI units may be approximate.

Standard Specification for Cored, Annular, Concentric-Lay-Stranded Copper Conductors

ICS
CCS
K11
发布
2004
实施

1.1 This specification covers concentric-lay-stranded conductors, made from round aluminum-alloy 6201-T81 (hard: solution heat-treated, cold worked, and then artificially aged) wires, for use for electrical purposes. These conductors shall be constructed with a central core surrounded by one or more layers of helically laid wires (Explanatory Notes 1 and 2). Note 18212;The aluminum alloy and temper designations conform to ANSI H35.1/H35.1[M]. Aluminum-alloy 6201 corresponds to Unified Numbering System alloy A96201 in accordance with Practice E527. 1.2 The values stated in inch-pound units or SI units are to be regarded separately as standard. The values in each system are not exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification. 1.2.1 For density, resistivity and temperature, the values stated in SI units are to be regarded as standard.

Standard Specification for Concentric-Lay-Stranded Aluminum-Alloy 6201-T81 Conductors

ICS
CCS
K11
发布
2004
实施

1.1 This test method covers the procedure for determining the cross-sectional area of stranded conductors by the mass method. 1.2 The values stated in inch-pound or SI units are to be regarded separately as the standard. The values in each system are not exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Method for Determination of Cross-Sectional Area of Stranded Conductors

ICS
CCS
K11
发布
2004
实施

1.1 This test method covers the procedure for determining the cross-sectional area of stranded conductors by the mass method.1.2 The values stated in inch-pound or SI units are to be regarded separately as the standard. The values in each system are not exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification.This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Method for Determination of Cross-Sectional Area of Stranded Conductors

ICS
CCS
K11
发布
2004
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号