K11 裸电线 标准查询与下载



共找到 506 条与 裸电线 相关的标准,共 34

1.1 This specification covers fiber reinforced, aluminum matrix composite core wire used for mechanical reinforcement in the manufacture of aluminum conductor, composite reinforced (ACCR). This wire consists of continuous filament fibers of aluminum oxide in a matrix of aluminum. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.2.1 Exception8212;Some non-standard SI units provided for information only do not appear in brackets. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Fiber Reinforced Aluminum Matrix Composite (AMC) Core Wire for Aluminum Conductors, Composite Reinforced (ACCR)

ICS
29.060.10
CCS
K11
发布
2011
实施

1.1 This specification covers round wire concentric-lay-stranded aluminum conductors, steel supported (ACSS) for use as overhead electrical conductors (see Explanatory Note 1). 1.2 The values stated in inch-pound or SI units are to be regarded separately as standard. Each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification. For conductor sizes designated by AWG or kcmil sizes, the requirements in SI units are numerically converted from the corresponding requirements in inch-pound units. For conductor sizes designation by AWG or kcmil, the requirements in SI units have been numerically converted from corresponding values stated or derived in inch-pound units. For conductor sizes designated by SI units only, the requirements are stated or derived in SI units. 1.2.1 For density, resistivity and temperature, the values stated in SI units are to be regarded as standard.

Standard Specification for Concentric-Lay-Stranded Aluminum Conductors, Coated Steel Supported (ACSS)

ICS
29.060.10 (Wires)
CCS
K11
发布
2011
实施

1.1 This specification covers bare concentric-lay-stranded conductors made from round copper wires, either uncoated or coated with tin, lead, or lead alloy for general use for electrical purposes. These conductors shall be constructed with a central core surrounded by one or more layers of helically laid wires. Note 18212;This specification also permits conductors for use as covered or insulated electrical conductors. Note 28212;Sealed conductors, that are intended to prevent longitudinal water propagation and are further covered/insulated, are also permitted within the guidelines of this specification. 1.2 For the purposes of this specification, conductors are classified as follows (Explanatory Note 1 and Note 2): 1.2.1 Class AA8212;For bare conductors usually used in overhead lines. 1.2.2 Class A8212;For conductors to be covered with weather-resistant (weather-proof), slow-burning materials, and for bare conductors where greater flexibility than is afforded by Class AA is required. 1.2.3 Class B8212;For conductors to be insulated with various materials such as rubber, paper, varnished cloth, and so forth, and for the conductors indicated under Class A where greater flexibility is required. 1.2.4 Class C and Class D8212;For conductors where greater flexibility is required than is provided by Class B conductors. 1.3 The SI values for density are regarded as the standard. For all other properties, the inch-pound values are to be regarded as standard and the SI units may be approximate.

Standard Specification for Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft

ICS
29.060.20
CCS
K11
发布
2011
实施

This British Standard specifies requirements for nickel-chromium-irontitanium- niobium-aluminium heat-resisting alloy round wire with a maximum diameter of 2 mm for thread inserts.

Specification for nickel-chromium-iron-titanium-niobium-aluminium heat-resisting alloy round wire with a maximum diameter of 2 mm for thread inserts (nickel base Cr 15.5, Fe 7.0, Ti 2.5, Nb/Ta 0.95, Al 0.70)

ICS
49.025.99
CCS
K11
发布
2010-11-30
实施
2010-11-30

This standard is applicable to thermal-resistant aluminium alloy wires before stranding for manufacture of stranded conductors for overhead lines. It specifies the mechanical, electrical and thermal-resistant properties of wires in the diameter range commercially available.

Thermal-resistant aluminium alloy wire for overhead line conductor (IEC 62004:2007, modified); German version EN 62004:2009

ICS
29.240.20
CCS
K11
发布
2010-05
实施
2010-05-01

This part of IEC 60851 specifies the following method of test: – Test 4: Dimensions. For definitions, general notes on methods of test and the complete series of methods of test for winding wires, see IEC 60851-1.

Winding wires - Test methods - Determination of dimensions

ICS
29.060.10
CCS
K11
发布
2010-01-31
实施
2010-01-31

1.1 This specification covers bare rope-lay-stranded conductors having concentric-stranded members made from round copper wires, either uncoated or coated with tin, lead, or lead-alloy for use as electrical conductors (Explanatory Note 1 and Note 2). 1.2 Coated wires shall include only those wires with finished diameters and densities substantially equal to the respective diameters and densities of uncoated wires. 1.3 The values stated in inch-pound or SI units are to be regarded separately as standard. Each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification. For conductor sizes designated by AWG or kcmil, the requirements in SI units have been numerically converted from corresponding values, stated or derived, in inch-pound units. For conductor sizes designated by SI units only, the requirements are stated or derived in SI units. 1.3.1 For density, resistivity, and temperature, the values stated in SI units are to be regarded as standard.

Standard Specification for Rope-Lay-Stranded Copper Conductors Having Concentric-Stranded Members, for Electrical Conductors

ICS
29.240.20 (Power transmission and distribution lin
CCS
K11
发布
2010
实施

1.1 This specification covers concentric-lay-stranded conductors made from round aluminum 1350-H19 (extra hard) aluminum wires and round aluminum-clad steel core wires for use as overhead electrical conductors (Explanatory Note 1 and Note 2). 1.2 The SI values of density and resistivity are to be regarded as standard. For all other properties the inch-pound units are regarded as standard and the SI units may be approximate.

Standard Specification for Concentric-Lay-Stranded Aluminum Conductors, Aluminum-Clad Steel Reinforced for Use in Overhead Electrical Conductors

ICS
29.240.20 (Power transmission and distribution lin
CCS
K11
发布
2010
实施

1.1 This specification covers tin-coated, round, soft, or annealed copper wire for electrical purposes. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.2.1 Exceptions8212;The SI values for density, resistivity, and volume are to be regarded as standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Tin-Coated Soft or Annealed Copper Wire for Electrical Purposes

ICS
29.060.10 (Wires)
CCS
K11
发布
2010
实施

1.1 This specification covers round, aluminum-clad steel core wire with two designations of tensile strengths, AW2 (Normal Strength) and AW3 (High Strength). 1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.2.1 For conductor sizes designated by AWG, the requirements in SI units have been numerically converted from corresponding values stated or derived in inch-pound units. For conductor sizes designated by SI units only, the requirements are stated or derived in SI units.

Standard Specification for Aluminum-Clad Steel Core Wire for Use in Overhead Electrical Aluminum Conductors

ICS
29.060.10 (Wires)
CCS
K11
发布
2010
实施

1.1 This specification covers tin-coated, round, soft, or annealed copper wire for electrical purposes. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.2.1 Exceptions—The SI values for density, resistivity, and volume are to be regarded as standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Tin-Coated Soft or Annealed Copper Wire for Electrical Purposes

ICS
29.060.10 (Wires)
CCS
K11
发布
2010
实施

1.1 This specification covers bare bunch-stranded conductors made from round copper wires, either uncoated or coated with tin, lead, or lead-alloy for use as electrical conductors (Explanatory Note 1 and Explanatory Note 2). 1.2 Coated wires shall include only those wires with finished diameters and densities substantially equal to the respective diameters and densities of uncoated wires. 1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.3.1 For conductor sizes designated by AWG or kcmil, the requirements in SI units have been numerically converted from corresponding values, stated or derived, in inch-pound units. For conductor sizes designated by SI units only, the requirements are stated or derived in SI units.

Standard Specification for Bunch-Stranded Copper Conductors for Electrical Conductors

ICS
29.060.20 (Cables)
CCS
K11
发布
2010
实施

1.1 This specification covers round, aluminum-clad steel core wire with two designations of tensile strengths, AW2 (Normal Strength) and AW3 (High Strength). 1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.2.1 For conductor sizes designated by AWG, the requirements in SI units have been numerically converted from corresponding values stated or derived in inch-pound units. For conductor sizes designated by SI units only, the requirements are stated or derived in SI units. 1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Aluminum-Clad Steel Core Wire for Use in Overhead Electrical Aluminum Conductors

ICS
29.060.10
CCS
K11
发布
2010
实施

1.1 This specification covers 7-wire, 19-wire, 37-wire, and 61-wire zinc-coated (galvanized), zinc-5 % aluminum-mischmetal alloy-coated stranded steel core intended for use in overhead electrical conductors. 1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

Standard Specification for Metallic Coated Stranded Steel Core for Use in Overhead Electrical Conductors

ICS
77.140.65
CCS
K11
发布
2010
实施

1.1 This specification covers bare rope-lay-stranded conductors having bunch-stranded members made from round copper wires, either uncoated or coated with tin, lead, or lead-alloy for use as electrical conductors (Explanatory Notes 1 and 2). 1.2 Coated wires shall include only those wires with finished diameters and densities substantially equal to the respective diameters and densities of uncoated wires. 1.3 The values stated in inch-pound or SI units are to be regarded separately as standard. Each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification. For conductor sizes designated by AWG or kcmil, the requirements in SI units have been numerically converted from corresponding values, stated or derived, in inch-pound units. For conductor sizes designated by SI units only, the requirements are stated or derived in SI units. 1.3.1 For density, resistivity, and temperature, the values stated in SI units are to be regarded as standard.

Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Members, for Electrical Conductors

ICS
29.060.20 (Cables)
CCS
K11
发布
2010
实施

ERRATUM

ICS
CCS
K11
发布
2009-10-14
实施

This European Standard is applicable to thermal-resistant aluminium alloy wires before stranding for manufacture of stranded conductors for overhead lines. It specifies the mechanical, electrical and thermal-resistant properties of wires in the diameter range commercially available.

Thermal-resistant aluminium alloy wire for overhead line conductor

ICS
29.060.10;29.240.20
CCS
K11
发布
2009-08-31
实施
2009-08-31

High strength grade thermo resistant aluminium alloy conductors ,steel reinforced

ICS
CCS
K11
发布
2009-04-20
实施

This is an interpretation of IEEE Std 605-1998. Interpretations are issued to explain and clarify the intent of a standard and are not intended to constitute an alteration to the original standard or to supply consulting information. Permission is hereby granted to download and print one copy of this document. Individuals seeking permission to reproduce and/or distribute this document in its entirety or portions of this document must contact the IEEE Standards Department for the appropriate license. Use of the information contained in this document is at your own risk.

Guide for Design of Substation Rigid-Bus Structures

ICS
CCS
K11
发布
2009-04
实施

Concentric lay stranded overhead electrical conductors containing one or more gap(s) (IEC 62420:2008); German version EN 62420:2008

ICS
29.240.20
CCS
K11
发布
2009-03
实施
2009-03-01