K42 电力电容器 标准查询与下载



共找到 282 条与 电力电容器 相关的标准,共 19

Shunt capacitors for a.c. power systems having a rated voltage above 1 000 V - Part 1 : general.

ICS
31.060.70
CCS
K42
发布
2006-03-01
实施
2006-03-20

This part of IEC 60871 is applicable to both capacitor units and capacitor banks intended to be used, particularly, for power-factor correction of a.c. power systems having a rated voltage above 1 000 V and frequencies of 15 Hz to 60 Hz. This part of IEC 60871 also applies to capacitors intended for use in power filter circuits. Additional definitions, requirements and tests for filter capacitors are given in Annex B. Additional requirements for capacitors protected by internal fuses as well as requirements for the internal fuses are given in IEC 60871-4. Requirements for capacitors to be protected by external fuses, as well as requirements for the same, are given in Annex C. This standard does not apply to capacitors of the self-healing metallized dielectric type. The following capacitors are excluded from this part of IEC 60871: – capacitors for inductive heat-generating plants operating at frequencies between 40 Hz and 24 000 Hz (IEC 60110-1); – series capacitors for power systems (see the IEC 60143 series); – capacitors for motor applications and the like (see the IEC 60252 series); – coupling capacitors and capacitor dividers (IEC 60358); – shunt capacitors for a.c. power systems having rated voltage up to and including 1 000 V (see the IEC 60831and IEC 60931 series); – small a.c. capacitors to be used for fluorescent and discharge lamps (IEC 61048 and IEC 61049); – capacitors to be used in power electronic circuits (IEC 61071); – capacitors for microwave ovens (IEC 61270-1); – capacitors for suppression of radio interference; – capacitors intended for use with d.c. voltage superimposed on a.c. voltage. Accessories such as insulators, switches, instrument transformers, external fuses, etc. are in accordance with the relevant IEC standards.

Shunt capacitors for a.c. power systems having a rated voltage above 1000 V - Part 1: General

ICS
31.060.70
CCS
K42
发布
2006-02-13
实施
2006-02-13

This part of IEC 60143 applies both to capacitor units and capacitor banks intended to be used connected in series with an a.c. transmission or distribution line or circuit forming part of an a.c. power system having a frequency of 15 Hz to 60 Hz. The primary focus of this standard is on transmission application. The series capacitor units and banks are usually intended for high-voltage power systems. This standard is applicable to the complete voltage range. This standard does not apply to capacitors of the self-healing metallized dielectric type. The following capacitors, even if connected in series with a circuit, are excluded from this standard: - capacitors for inductive heat-generating plants (IEC 60110-1); - capacitors for motor applications and the like (IEC 60252-1); - capacitors to be used in power electronics circuits (IEC 61071); - capacitors for discharge lamps (IEC 61048 and IEC 61049). Standard types of accessories such as insulators, switches, instrument transformers, external fuses, etc. should comply with the pertinent IEC standard. NOTE 1 Additional requirements for capacitors to be protected by internal fuses, as well as the requirements for internal fuses, are found in IEC 60143-3. NOTE 2 Additional requirements for capacitors to be protected by external fuses, as well as the requirements for external fuses, are found in Annex A. NOTE 3 A separate standard for series capacitor accessories (spark-gaps, non-linear resistors, discharge reactors, current-limiting damping reactors, damping resistors, circuit-breakers, etc.), IEC 60143-2, was completed in 1994. A separate standard for internal fuses for series capacitors, IEC 60143-3 (formerly IEC 60595), has been revised and was completed in 1998. The object of this standard is: - to formulate uniform rules regarding performance, testing and rating; - to formulate specific safety rules; - to serve as a guide for installation and operation.

Series capacitors for power systems - General

ICS
31.060.70
CCS
K42
发布
2005-09-30
实施
2005-09-30

This part of IEC 60871 is applicable to both capacitor units and capacitor banks intended to be used, particularly, for power-factor correction of a.c. power systems having a rated voltage above 1000 V and frequencies of 15 Hz to 60 Hz. This part of IEC

Shunt capacitors for a.c. power systems having a rated voltage above 1000 V - Part 1: General

ICS
31.060.70
CCS
K42
发布
2005-07
实施
2014-05-24

이 규격은 교류의 전압, 전류, 유효 전력, 무효 전력, 위상각, 역률, 무효율, 주파수와

Electrical measuring transducers for converting A.C.electrical quantities into D.C. electrical quantities

ICS
29.2
CCS
K42
发布
2005-06-30
实施
2005-06-30

本标准规定了单台电力电容器(以下简称“单台电容器”或“电容器”)及电力电容器装置(以下简称“电容器装置”或“装置”)型号的编制方法。 本标准适用于单台电容器及电容器装置等型号的编制。

Rules for determination of the types of power capacitor products

ICS
31.060.70
CCS
K42
发布
2005-05-18
实施
2005-11-01

Applies to outdoor series capacitor banks and to the major components of a bank that are required to form a complete system for the insertion of capacitors in series with a transmission line.

Standard for Series Capacitors in Power Systems

ICS
29.240.99
CCS
K42
发布
2005-02-07
实施

Series capacitors for power systems - Part 1 : general.

ICS
31.060.70
CCS
K42
发布
2004-07-01
实施
2004-07-05

Power capacitors - Low-voltage power factor correction banks (IEC 61921:2003); German version EN 61921:2003

ICS
31.060.70
CCS
K42
发布
2004-02
实施
2004-02-01

이 규격은 50 Hz 및 60 Hz와 1 000 V를 초과하는 정격 전압을 가진 교류

High-voltage fuses-Part 1:Current-limiting fuses

ICS
29.120.50
CCS
K42
发布
2003-12-29
实施
2003-12-29

이 규격은 정격 전압 1 000 V 이상, 주파수 50 또는 60 Hz인 교류 전력 계

High-voltage fuses-Part 2:Expulsion fuses

ICS
29.120.50
CCS
K42
发布
2003-12-29
实施
2003-12-29

이 규격은 이상이 있는 커패시터 엘리먼트 또는 커패시터 장치와 커패시터 장치가 연결되는

Shunt power capacitors of the non-self-healing type for a.c.systems having a rated voltage up to and including 1 000 V-Part 3:Internal fuses

ICS
31.060.70
CCS
K42
发布
2003-12-11
实施
2003-12-11

이 규격은 KS C IEC 60931-1에 따라 커패시터에 적용되며, 이들 커패시터를

Shunt power capacitors of the non-self-healing type for a.c.systems having a rated voltage up to and including 1 000 V-Part 2:Ageing test and destruction test

ICS
31.060.70
CCS
K42
发布
2003-12-11
实施
2003-12-11

1.1 이 규격은 40∼24 000 Hz의 주파수에서 작용하는 유도 가열 장치용 커패시

Internal fuses and internal overpressure disconnectors for capacitors for inductive heat generating plants

ICS
29.120.99;31.060.70
CCS
K42
发布
2003-11-03
实施
2003-11-03

이 규격은 정격 전압 1 000 V 이하와 15∼60 Hz 주파수의 교류 전력 시스템의

Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V-Part 1:General-Performance, testing and rating-Safety requirements-Guide for installation and operation

ICS
29.120.99;31.060.70
CCS
K42
发布
2003-11-03
实施
2003-11-03

이 규격은 KS C IEC 60831-1에 따르는 커패시터의 열화 시험, 자기-복귀 시

Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V-Part 2:Ageing test, self-healing test and destruction test

ICS
29.120.99;31.060.70
CCS
K42
发布
2003-11-03
实施
2003-11-03

이 규격은 이상이 생긴 커패시터 엘리먼트를 분리하기 위해 고안된 내부 퓨즈 및 커패시터

Shunt capacitors for AC power systems having a rated voltage above 1 000V-Part 4:Internal fuses

ICS
29.240.99;31.060.70
CCS
K42
发布
2003-11-03
实施
2003-11-03

This International Standard applies to motor start capacitors intended for connection to windings of asynchronous motors supplied from a single-phase system having the frequency of the mains. This standard covers impregnated or unimpregnated metallized motor start capacitors having a dielectric of paper or plastic film, or a combination of both and electrolytic motor start capacitors with non-solid electrolyte, with rated voltages up to and including 660 V.

A.C. motor capacitors. Motor start capacitors

ICS
31.060.70
CCS
K42
发布
2003-10-29
实施
2003-10-29

This International Standard is applicable to low-voltage a.c. capacitor banks intended to be used for power factor correction purposes, equipped with a built-in switchgear and controlgear apparatus capable of connecting to or disconnecting from the mains part(s) of the bank with the aim to correct its power factor. Low-voltage power factor correction banks if not otherwise indicated hereinafter and where applicable shall comply with the requirements of IEC 60439-1 and those of IEC 60439-3.

Power capacitors. Low-voltage power factor correction banks

ICS
31.060.70
CCS
K42
发布
2003-10-27
实施
2003-10-27

ERRATUM

ICS
CCS
K42
发布
2003-08-20
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved