L15 敏感元器件及传感器 标准查询与下载



共找到 409 条与 敏感元器件及传感器 相关的标准,共 28

本规程适用于应变式力传感器(以下简称力传感器)的首次检定、后续检定和使用中检验。

Verification Regulation of Force Transducers

ICS
CCS
L15
发布
2009-10-09
实施
2010-04-09

This SAE Information Report defines the minimum performance specifications for accelerometers, load cells, and angular position transducers used within Anthropomorphic Test Devices (ATDs) when performing impact tests per SAE J211, "Instrumentation for Impact Test". This report does not define methodology and equipment for performing verification tests of the transducers. It is intended that any agency proposing to conduct tests in accordance with SAE J211 should be able to demonstrate that the transducers they use would meet the performance requirements specified in this information report. The purpose of this information report is to provide guidelines for choosing accelerometers, load cells, and angular position transducers for use in impact testing. The aim is to provide uniformity in transducer measurements, and provide a basis for meaningful comparisons of test results from different sources.

Performance Specifications for Anthropomorphic Test Device Transducers

ICS
43.180
CCS
L15
发布
2009-08-12
实施
2009-08-14

Methods for the calibration of vibration and shock transducers - Part 21: Vibration calibration by comparison to a reference transducer (ISO 16063-21:2003), Corrigendum to DIN ISO 16063-21:2004-01 (ISO 16063-21:2003/Cor. 1:2009)

ICS
17.160
CCS
L15
发布
2009-08
实施

Methods for the calibration of vibration and shock transducers - Part 31: Testing of transverse vibration sensitivity

ICS
17.160
CCS
L15
发布
2009-08
实施

High frequency inductive components -- Non-electrical characteristics and measuring methods -- Part 2: Test methods for non-electrical characteristics

ICS
29.100.10
CCS
L15
发布
2009-07-20
实施

Directly heated negative temperature coefficient thermistors - Blank detail specification - Sensing application - Assessment level EZ

ICS
31.040.30
CCS
L15
发布
2009-05-31
实施
2009-05-31

本规范规定了用于地面气象观测的温湿传感器防辐射设备(以下简称防辐射设备)的通用技术要求、质量保证规定以及交货准备等。 本规范适用于防辐射设备的设计、生产、检验和验收。

General specification for radiation shield of temperature and humidity probes

ICS
CCS
L15
发布
2009-05-25
实施
2009-08-01

本规范规定了大气静电场传感器标定设备(以下简称标定设备)的通用要求。 本规范适用于大气静电场传感器标定设备的研制、生产和产品验收。

General specification for calibration equipment of atmosphere electrostatic field sensor

ICS
CCS
L15
发布
2009-05-25
实施
2009-08-01

This part of IEC 60747 specifies requirements for semiconductor pressure sensors measuring absolute@ gauge or differential pressures.

Semiconductor devices - Part 14-3: Semiconductor sensors - Pressure sensors

ICS
31.080.99
CCS
L15
发布
2009-04
实施
2009-05-04

Polymeric thermistors - Directly heated positive step function temperature coefficient - Part 1: Generic specification; Corrigendum 1

ICS
31.040.30
CCS
L15
发布
2009-03
实施

Pressure transducers

ICS
11.040.55
CCS
L15
发布
2008-11-25
实施

Directly heated negative temperature coefficient thermistors - Part 1: Generic specification (IEC 60539-1:2008); German version EN 60539-1:2008

ICS
31.040.30
CCS
L15
发布
2008-11
实施
2008-11-01

1.1 Method(s) of mounting (to be inserted) (See 4.4 of IEC 60539-1:2008.) 1.2 Dimensions (All dimensions are in millimetres or inches and millimetres; it shall be stated which dimensions are suitable for gauging.) Dimensioned drawing(s) shall be given in the detail specification. If necessary, the dimensions may be listed in tabular form with reference to styles or codes. 1.3 Coating The detail specification shall state: a) whether the thermistor is insulated or non insulated; b) the material; c) the colour, if applicable. 1.4 Terminations The detail specification shall state whether the terminations are suitable for soldering. If they are not, suitable methods of connection shall be stated for example: welding, clamping or crimping. 1.5 Flammability The detail specification shall state whether the thermistor is actively or passively flammable, if applicable. The test method shall be given in the test schedule. 1.6 Resistance to solvents The detail specification shall state whether the coating and the marking of the thermistor are solvent resistant, if applicable. The test methods shall be given in the test schedule. 1.7 Packaging The detail specification shall give the following information (if required): a) whether bulk packed or taped and if taped, drawing or references; b) the dimensions of the immediate packaging and the number of thermistors packed; c) the dimensions of the outer package and the number of immediate packages; d) methods of disposal of the packaging material.

Directly heated negative temperature coefficient thermistors - Part 1-1: Blank detail specification - Sensing application - Assessment level EZ

ICS
31.040.30
CCS
L15
发布
2008-11
实施

이 표준은 시간 종속 충격을 위한 기준 가속도, 속도 또는 힘의 측정을 이용하여 직선 변환

Methods for the calibration of vibration and shock transducers-Part 22:Shock calibration by comparison to a reference transducer

ICS
17.160
CCS
L15
发布
2008-10-17
实施
2008-10-17

IEC/PAS 60539-1-1: Thermistors - Directly heated negative temperature coefficient - Part 1-1: Blank detail specification - Sensing application

ICS
31.040.30
CCS
L15
发布
2008-08
实施

This standard specifies the requirements and temperature/resistance relationship for industrial platinum resistance temperature sensors later referred to as "platinum resistors" or "resistors" and industrial platinum resistance thermometers later referred to as "thermometers" whose electrical resistance is a defined function of temperature. Values of temperature in this standard are in terms of the International Temperature Scale of 1990, ITS-90. Temperatures in degrees Celsius are denoted by the symbol t, except in Table 1 where the full nomenclature t/℃is used. The standard covers resistors or thermometers for all or part of the temperature range -200 ℃ to +850 ℃ with different tolerance classes, which may cover restricted temperature ranges. For temperature/resistance relationships with uncertainties

Industrial platinium resistance thermometer and platinum temperature sensors

ICS
17.200.20
CCS
L15
发布
2008-07
实施

This part of IEC 60539 is applicable to directly heated negative temperature coefficient thermistors, typically made from transition metal oxide materials with semiconducting properties. It establishes standard terms, inspection procedures and methods of test for use in sectional and detail specifications of electronic components for quality assessment or any other purpose.

Directly heated negative temperature coefficient thermistors — Part 1: Generic specification

ICS
31.040.30
CCS
L15
发布
2008-06-30
实施

1.1 Method(s) of mounting (to be inserted) (See IEC 60738-1:2006, 7.30). 1.2 Dimensions (All dimensions are in millimetres or inches and millimetres; it shall be stated which dimensions are suitable for gauging). Dimensioned drawing(s) shall be given in the detail specification. If necessary, the dimensions may be listed in tabular form with reference to styles or codes. 1.3 Coating The detail specification shall state a) whether the thermistor is insulated or non-insulated, b) the material, c) the colour, if applicable. 1.4 Terminations The detail specification shall state whether the terminations are suitable for soldering. If they are not, suitable methods of connection shall be stated for example: welding, clamping or crimping. 1.5 Flammability The detail specification shall state whether the thermistor is actively or passively flammable if applicable. The test method shall be given in the test schedule. 1.6 Resistance to solvents The detail specification shall state whether the coating and the marking of the thermistor are solvent resistant if applicable. The test methods shall be given in the test schedule. 1.7 Packaging The detail specification shall give the following information (if required): a) whether bulk packed or taped and if taped, drawing or references; b) the dimensions of the immediate packaging and the number of thermistors packed; c) the dimensions of the outer package and the number of immediate packages; d) methods of disposal of the packaging material. 1.8 Electrical data/Ratings and characteristics The detail specification shall give units and tolerances or limiting values for the following parameters. If necessary, electrical data may be listed in tabular form, with reference to styles and codes. Upper/Lower category temperatures (UCT/LCT); Operating temperature range at maximum voltage; Maximum voltage (Umax.); Zero-power resistance (RT); Isolation voltage (insulated thermistors only); Insulation resistance (insulated thermistors only); Tripping current (It); Maximum non-tripping current (Imax. nt); Residual current at Umax. (Ires); Maximum overload current (Imo); Switching temperature (Tb) for information only.

Thermistors - Directly heated positive step-function temperature coefficient - Part 1-1: Blank detail specification - Current limiting application - Assessment level EZ

ICS
31.040.30
CCS
L15
发布
2008-06-30
实施
2008-06-30

1.1 Method(s) of mounting (to be inserted) (See IEC 60738-1:2006, 7.30). 1.2 Dimensions (All dimensions are in millimetres or inches and millimetres; it shall be stated which dimensions are suitable for gauging). Dimensioned drawing(s) shall be given in the detail specification. If necessary, the dimensions may be listed in tabular form with reference to styles or codes. 1.3 Coating The detail specification shall state a) whether the thermistor is insulated or non-insulated, b) the material, c) the colour, if applicable. 1.4 Terminations The detail specification shall state whether the terminations are suitable for soldering. If they are not, suitable methods of connection shall be stated for example: welding, clamping or crimping. 1.5 Flammability The detail specification shall state whether the thermistor is actively or passively flammable if applicable. The test method shall be given in the test schedule. 1.6 Resistance to solvents The detail specification shall state whether the coating and the marking of the thermistor are solvent resistant if applicable. The test methods shall be given in the test schedule. 1.7 Packaging The detail specification shall give the following information (if required): a) whether bulk packed or taped and if taped, drawing or references; b) the dimensions of the immediate packaging and the number of thermistors packed; c) the dimensions of the outer package and the number of immediate packages; d) methods of disposal of the packaging material.1.8 Electrical data/Ratings and characteristics The detail specification shall give units and tolerances or limiting values for the following parameters. If necessary, electrical data may be listed in tabular form, with reference to styles and codes. Upper/Lower category temperatures (UCT/LCT); Operating temperature range at maximum voltage; Maximum voltage (Umax.); Zero-power resistance (RT); Switching temperature (Tb); Either inrush current (Iin); or minimum resistance (Rmin.); Either residual current (Ires); or Resistance(Rp); or Final surface temperature (TFS)1.

Thermistors - Directly heated positive step-function temperature coefficient - Part 1-2: Blank detail specification - Heating element application - Assessment level EZ

ICS
31.040.30
CCS
L15
发布
2008-06-30
实施
2008-06-30

1.1 Method(s) of mounting (to be inserted) (See IEC 60738-1:2006, 7.30). 1.2 Dimensions (All dimensions are in millimetres or inches and millimetres; it shall be stated which dimensions are suitable for gauging). Dimensioned drawing(s) shall be given in the detail specification. If necessary, the dimensions may be listed in tabular form with reference to styles or codes. 1.3 Coating The detail specification shall state: a) whether the thermistor is insulated or non-insulated; b) the material; c) the colour, if applicable. 1.4 Terminations The detail specification shall state whether the terminations are suitable for soldering. If they are not, suitable methods of connection shall be stated for example: welding, clamping or crimping. 1.5 Flammability The detail specification shall state whether the thermistor is actively or passively flammable if applicable. The test method shall be given in the test schedule. 1.6 Resistance to solvents The detail specification shall state whether the coating and the marking of the thermistor are solvent resistant if applicable. The test methods shall be given in the test schedule. 1.7 Packaging The detail specification shall give the following information (if required): a) whether bulk packed or taped and if taped, drawing or references; b) the dimensions of the immediate packaging and the number of thermistors packed; c) the dimensions of the outer package and the number of immediate packages; d) methods of disposal of the packaging material.1.8 Electrical data/Ratings and characteristics The detail specification shall give units and tolerances or limiting values for the following parameters. If necessary, electrical data may be listed in tabular form, with reference to styles and codes. Upper/Lower category temperatures (UCT/LCT); Operating temperature range at maximum voltage; Maximum voltage (Umax.); Zero-power resistance (RT) of series PTC; Zero-power resistance (RT) of parallel PTC; Isolation voltage (insulated thermistors only); Insulation resistance (insulated thermistors only); Minimum series impedance (coil); Minimum peak-to-peak inrush current (Iin pp max.); Maximum peak-to-peak inrush current (Iin pp min.); Residual current at Umax. (Ires).

Thermistors - Directly heated positive step-function temperature coefficient - Part 1-3: Blank detail specification - Inrush current application - Assessment level EZ

ICS
31.040.30
CCS
L15
发布
2008-06-30
实施
2008-06-30



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号