N65 声学仪器与测震仪 标准查询与下载



共找到 317 条与 声学仪器与测震仪 相关的标准,共 22

本规范适用于空气声平面阵列声源识别定位系统(波束形成法)的校准。

Calibration Specification for Sound Source Identification and Localization Systems (Beamforming Method)

ICS
CCS
N65
发布
2014-11-17
实施
2015-02-17

Methods for the calibration of vibration and shock transducers. Calibration of seismometers with high accuracy using acceleration of gravity

ICS
17.160
CCS
N65
发布
2014-09-30
实施
2014-09-30

Specific requirements for the competence of testing laboratories for noise and vibration in the field of immission control

ICS
03.120.20;17.140.01;17.160
CCS
N65
发布
2014-07-01
实施

Electroacoustics - Sound level meters - Part 3: Periodic tests (IEC 61672-3:2013); German version EN 61672-3:2013

ICS
17.140.50
CCS
N65
发布
2014-07-01
实施

Sound level meters - Additional requirements for special measuring tasks

ICS
17.140.50
CCS
N65
发布
2014-07-01
实施

Methods for the calibration of vibration and shock transducers. Calibration by Earth’s gravitation

ICS
17.160
CCS
N65
发布
2014-06-30
实施
2014-06-30

Electroacoustics. Sound level meters. Pattern evaluation tests

ICS
17.140.50
CCS
N65
发布
2014-01-31
实施
2014-01-31

本规范规定了宽带同轴噪声发生器(以下简称噪声发生器)的校准项目、校准条件、校准方法、校准结果表达、复校时间间隔等,适用于频率范围为10 MHz~40 GHz噪声发生器的校准。

Calibration Specification for Broadband Coaxial Noise Generators

ICS
CCS
N65
发布
2014-01-23
实施
2014-04-23

本规范适用于用传递函数法测量吸声材料吸声系数阻抗管的校准。

Calibration Specification for Impedance Tubes (Transfer Function Method)

ICS
CCS
N65
发布
2014-01-23
实施
2014-04-23

Sound system equipment: Headphones and earphones associated with personal music players. Maximum sound pressure level measurement methodology. Matching of sets with headphones if either or both are offered separately, or are offered as one package equipme

ICS
17.140.50;33.160.50
CCS
N65
发布
2013-10-31
实施
2013-10-31

本标准规定了飞机噪声评定用声测量系统的电声性能要求,并给出了用以验证其性能是否满足规定允差要求的定期检测方法。一般来说,此类声测量系统是指从传声器经由数据记录和处理设备连接到合适输出的仪器的组合。组成结构不同的特殊测量系统,采用不同的方法完成必要功能,以模拟或数字的方式运行。本标准的目的是保证在规定的参考环境条件下,在规定的允差范围内,不同的测量系统具有相同的电声性能。本标准没有提供传声器和传声器防风罩的安装建议,也没有提供飞机噪声评定用测量程序和分析程序的相关要求,仅提供了时间间隔内平均的1/3 oct声压级测量系统的性能指标。某些要求适用于整个测量系统,包括任何分析前用于记录被测声压信号时域波形的装置。某些要求特别适用于将所接收到的声压转换为电信号的传声器。还有一些要求仅适用于处理以1/3 oct声压级形式提供输出信号的仪器。本标准适用于测量飞机噪声的仪器,这类噪声可由最大起飞质量超过9000 kg的喷气式或螺旋桨驱动的运输机产生,或是由安装在合适的室外发动机试验台的上述飞机发动机产生。

Electroacoustics.Instruments for measurement of aircraft noise.Performance requirements for systems to measure one-third-octave band sound pressure levels in noise certification of transport-category aeroplanes

ICS
17.140.50
CCS
N65
发布
2013-10-17
实施
2013-12-01

本标准规定了测量电容传声器(以下简称传声器)的术语和定义、电声性能的测量条件和测量方法。本标准适用于实验室标准传声器、工作标准传声器和工程测量传声器。

Electroacoustics.Measurement methods of electroacoustic characteristics for measurement condenser microphones

ICS
17.140.50
CCS
N65
发布
2013-10-17
实施
2013-12-01

本标准规定了测量电容传声器(以下简称传声器)的分类、要求、测量方法、质量评定程序以及标志、包装、贮存和运输。本标准适用于实验室标准传声器、工作标准传声器和工程测量传声器。

Electroacoustics.General specification of measurement condenser microphones

ICS
17.140.50
CCS
N65
发布
2013-10-17
实施
2013-12-01

이 표준은 진동에 대한 인체의 반응을 평가하기 위한 목적으로 행해지는 진동값을 측정하기 위하여설계되는 기기에 대한 성능 명세서와 공차 한계에 대하여 규정한다. 이 표준에는 패턴 평가를 위한요건, 정기 검사, 현장 검사 및 현장 검사를 위한 진동 교정기의 표준을 포함하고 있다.이 표준에 의해 규정된 진동장치는 단일 장치 또는 장치들의 조합이거나 컴퓨터를 기반으로 한 수집과 분석 시스템임을 규정한다.이 표준에 상술되어 있는 진동 기구는 다음과 같이 하나 혹은 그 이상의 응용범위에 대해 진동을 측정하고자 하는 데 목적을 두고 있다.― 손으로 전달된 진동(KS B ISO 5349-1 참조)― 전신진동(KS B ISO 2631-1, KS B ISO 2631-2, KS B ISO 2631-4 참조)― 주파수 0.1 Hz~0.5 Hz의 저주파 전신진동(KS B ISO 2631-1 참조)진동장치는 이러한 응용 범위에서 정의된 하나 또는 그 이상의 주파수 가중에 따라 측정을 수행할수 있도록 설계할 수 있다.성능 평가의 세 가지 수준은 이 표준에서 아래와 같이 정의한다.a) 패턴 평가:이 표준에 의해 정의된 표준에 대한 장치의 모든 검사b) 정기 검사:장치가 요구되는 성능 명세를 만족하는지 여부를 보증할 수 있도록 설계된 중간 수준의 검사c) 현장 검사:장치가 요구되는 성능 명세를 만족하는

Human response to vibration-Measuring instrumentation

ICS
13.160
CCS
N65
发布
2013-08-06
实施
2013-08-06

This part of ISO 018436 specifies the requirements for qualification and assessment of personnel who perform machinery condition monitoring and diagnostics using ultrasound. A_ certificate or declaration of conformity to this part of ISO 18436 provides recognition of the qualifications and competence of individuals to perform ultrasound measurements and analysis for machinery condition monitoring using ultrasound equipment. It is possible that this procedure is not applicable to specialized eduipment or other specific Situations. This partofISO 18436 specifies athree-category classification programmethatis based on thetechnical areas delineated herein, consistent with ISO 18436-1 and ISO 18436-3.

Condition monitoring and diagnostics of machines - Requirements for qualification and assessment of personnel - Part 8: Ultrasound

ICS
03.100.30;17.160
CCS
N65
发布
2013-03
实施

Electroacoustics - Methods to determine corrections to obtain the free-field response of a sound level meter

ICS
17.140.50
CCS
N65
发布
2013-02-02
实施
2013-02-02

4.1 The purpose of this practice is to enable the transfer of calibration from sensors that have been calibrated by primary calibration to other sensors. 1.1 This practice covers requirements for the secondary calibration of acoustic emission (AE) sensors. The secondary calibration yields the frequency response of a sensor to waves of the type normally encountered in acoustic emission work. The source producing the signal used for the calibration is mounted on the same surface of the test block as the sensor under testing (SUT). Rayleigh waves are dominant under these conditions; the calibration results represent primarily the sensor''s sensitivity to Rayleigh waves. The sensitivity of the sensor is determined for excitation within the range of 100 kHz to 1 MHz. Sensitivity values are usually determined at frequencies approximately 10 kHz apart. The units of the calibration are volts per unit of mechanical input (displacement, velocity, or acceleration). 1.2 Units—The values stated in either SI units or inch-pound units are to be regarded as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standards. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Practice for Secondary Calibration of Acoustic Emission Sensors

ICS
17.140.01 (Acoustic measurements and noise abateme
CCS
N65
发布
2013
实施

This part of the IEC 61094 series is applicable to working standard microphones meeting the requirements of IEC 61094-4. It describes methods of determining the free-field sensitivity by comparison with a laboratory standard microphone or working standard microphone (where applicable) that has been calibrated according to either: ?? IEC 61094-3@ ?? IEC 61094-2 or IEC 61094-5@ and where factors given in IEC/TS 61094-7 have been applied@ ?? IEC 61094-6@ ?? this part of IEC 61094. Methods performed in an acoustical environment that is a good approximation to an ideal free-field (e.g. a high quality free-field chamber)@ and methods that use post processing of results to minimise the effect of imperfections in the acoustical environment@ to simulate freefield conditions@ are both covered by this part of IEC 61094. Comparison methods based on the principles described in IEC 61094-3 are also possible but beyond the scope of this part of IEC 61094. NOTE 1 This part of IEC 61094 is also applicable to laboratory standard microphones meeting the requirements of IEC 61094-1@ noting that these microphones also meet the electroacoustic specifications for working standard microphones. NOTE 2 This part of IEC 61094 is also applicable to combinations of microphone and preamplifier where the determined sensitivity is referred to the unloaded output voltage of the preamplifier. NOTE 3 Other devices@ for example@ sound level meters can be calibrated using the principles of this part of IEC 61094@ but are not within the scope of this standard.

Measurement microphones - Part 8: Methods for determining the free-field sensitivity of working standard microphones by comparison

ICS
17.140.50;33.160.50
CCS
N65
发布
2012-09
实施
2012-09-21

Vibration measuring instrumentation - Vocabulary

ICS
01.040.17;17.160
CCS
N65
发布
2012-08
实施

Green coffee. Procedure for calibration of moisture meters. Routine method

ICS
67.140.20
CCS
N65
发布
2012-06-30
实施
2012-06-30



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号