N65 声学仪器与测震仪 标准查询与下载



共找到 317 条与 声学仪器与测震仪 相关的标准,共 22

Mechanical vibration of rotating and reciprocating machinery. Requirements for instruments for measuring vibration severity

ICS
17.160
CCS
N65
发布
2012-04-30
实施
2012-04-30

本规程适用于纯音听力计的首次检定、后续检定和使用中的检查。

Verification Regulation of Audiological equipment pure-tone audiometers

ICS
CCS
N65
发布
2012-04-17
实施
2012-10-17

This International Standard specifies requirements which it is necessary for a measuring instrument for vibration severity of machines to meet if inaccuracies of measurement made on the casing of machines, particularly when making repeated measurements for trend monitoring of a certain machine, are not to exceed a specific value. The instruments covered by this International Standard give direct indication or recording of root-mean-square (r.m.s.) vibration velocity that is defined as a measurement unit. NOTE 1 A method of checking true r.m.s. indication is described in Annex A. This method is mainly retained for instruments not based on modern analogue to digital conversion and numerical calculation of r.m.s., but can also be applied to instruments which are so based. NOTE 2 Subject to adaptation of the measurement frequency range, these instruments can be used for other applications where similar accuracy of measurement is required, measurement of vibration velocity of structures, tunnels, bridges, etc. Optionally phase measurements may be included.

Mechanical vibration of rotating and reciprocating machinery - Requirements for instruments for measuring vibration severity

ICS
17.160
CCS
N65
发布
2012-04-01
实施

本规范适用于测量耳机、传声器、扬声器、受话器、送话器等电声器件电声特性的电声测试仪的校准。

Calibration Specification for Electro-acoustical Measurement Instruments

ICS
CCS
N65
发布
2012-03-20
实施
2012-06-20

本规范适用于常压下20Hz~2000Hz频率范围内使用的矢量水听器的校准。

Calibration Specification for Vector Hydrophones in Frequency Range 20 Hz to 2 000 Hz

ICS
CCS
N65
发布
2012-03-20
实施
2012-06-20

Transfer Standards8212;One purpose of this test method is for the direct calibration of displacement transducers for use as secondary standards for the calibration of AE sensors for use in nondestructive evaluation. For this purpose, the transfer standard should be high fidelity and very well behaved and understood. If this can be established, the stated accuracy should apply over the full frequency range up to 1 MHz. Note 18212;The stated accuracy applies only if the transfer standard returns to quiescence, following the transient input, before any wave reflected from the boundary of the calibration block returns to the transfer standard (8764;100 μs). For low frequencies with periods on the order of the time window, this condition is problematical to prove. Applications Sensors8212;This test method may also be used for the calibration of AE sensors for use in nondestructive evaluation. Some of these sensors are less well behaved than devices suitable for a transfer standard. The stated accuracy for such devices applies in the range of 100 kHz to 1 MHz and with less accuracy below 100 kHz.1.1 This test method covers the requirements for the absolute calibration of acoustic emission (AE) sensors. The calibration yields the frequency response of a transducer to waves, at a surface, of the type normally encountered in acoustic emission work. The transducer voltage response is determined at discrete frequency intervals of approximately 10 kHz up to 1 MHz. The input is a given well-established dynamic displacement normal to the mounting surface. The units of the calibration are output voltage per unit mechanical input (displacement, velocity, or acceleration). 1.2 Units8212;The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Method for Primary Calibration of Acoustic Emission Sensors

ICS
17.140.01 (Acoustic measurements and noise abateme
CCS
N65
发布
2012
实施

Methods for the calibration of vibration and shock transducers. Calibration of laser vibrometers

ICS
17.160
CCS
N65
发布
2011-09-30
实施
2011-09-30

This SAE Aerospace Standard (AS) specifies minimum performance standards for Acoustic Underwater Locating Devices which are primarily intended for use with both fixed and rotary wing civil aircraft. This AS covers ULD utilized in finding flight data recorders, cockpit recorders or aircraft. Such ULDs are installed adjacent to the recorders in a manner that they are unlikely to become separated during crash conditions.

Minimum Performance Standard for Underwater Locating Devices (Acoustic) (Self-Powered)

ICS
49.090
CCS
N65
发布
2011-08-03
实施

本规范规定了用于测定传声器频率响应的静电激励器的计量特性、校准条件和校准方法。 本规范适用于测定传声器频率响应的静电激励器的校准。

Calibration Specification for Electrostatic Actuators

ICS
CCS
N65
发布
2011-07-04
实施
2011-10-04

本规程适用于在频率为0.5MHz~5MHz范围内使用的标准水听器的首次检定、后续检定和使用中检查。

Verification Regulation of Standard Hydrophones in the Frequency Range 0.5 MHz to 5 MHz (Two-transducer Reciprocity Method)

ICS
CCS
N65
发布
2011-07-04
实施
2011-10-04

本规范规定了耳声发射测量仪的计量特性、校准条件和校准方法。 本规范适用于耳声发射测量仪的校准。

Calibration Specification for Measurement Instruments of Otoacoustic Emissions

ICS
CCS
N65
发布
2011-06-14
实施
2011-09-14

Electroacoustics - Audiometric equipment - Part 6: Instruments for the measurement of otoacoustic emissions (IEC 60645-6:2009); German version EN 60645-6:2010

ICS
13.140
CCS
N65
发布
2010-08
实施
2010-08-01

Electroacoustics - Audiometric equipment - Part 7: Instruments for the measurement of auditory brainstem responses (IEC 60645-7:2009); German version EN 60645-7:2010

ICS
13.140
CCS
N65
发布
2010-08
实施
2010-08-01

This part of ISO 11546 specifies laboratory methods for the determination of sound insulation performance (insertion loss) of small machine enclosures. It applies to a total enclosure only and not to the individual panels from which the enclosure is made. The measurement methods specified in this part of ISO 11546 are based on International Standard in the series ISO 3740,ISO 9614 and ISO 11200 (see table 1).Depending on the method chosen,the sound insulation performance (insertion loss) of the enclosure is determined in terms of the reduction of sound power level or sound pressure level.Methods are given for measurements where the enclosure surrounds the actual sound source (machine).Where these methods are not practicable ,alternative measurements can be performed using a reciprocity method (see definition 3.11 and subclause 7.2) or an artificial sound source.

Acoustics - Determination of sound insulation performances of enclosures - Measurements under laboratory conditions (for declaration purposes)

ICS
17.140.01
CCS
N65
发布
2010-05-31
实施
2010-05-31

This part of ISO 11546 specifies in situ methods for the determination of the sound insulation performance (insertion loss) of machine enclosures. It applies to a total enclosure only and not to the individual panels from which the enclosure is made.

Acoustics - Determination of sound insulation performances of enclosures - Measurements in situ (for acceptance and verification purposes)

ICS
17.140.01
CCS
N65
发布
2010-04-30
实施
2010-04-30

本规程适用于静水压0.1 MPa-10 MPa、频率 20 Hz~3.15 kHz 范围内使用的耐高静水压标准水听器(以下简称标准水听器)的首次检定、后续检定和使用中的检验。

Verification Regulation of Standard Hydrophones in the Frequency Range 20 Hz to 3.15 kHz under High Hydrostatic Pressure (Acoustic Coupler Reciprocity Method)

ICS
CCS
N65
发布
2010-03-02
实施
2010-06-02

This part of IEC 60645 applies to instruments designed for the measurement of auditory evoked potentials from the inner ear, the auditory nerve and the brainstem, evoked by acoustic and/or vibratory stimuli of short duration. This part of IEC 60645 defines the characteristics to be specified by the manufacturer, specifies performance requirements for two types of instrument, screening and diagnostic, and specifies the functions to be provided on these types. The purpose of this part of IEC 60645 is to ensure that measurements made under comparable test conditions with different instruments complying with this standard will be consistent. This part of IEC 60645 is not intended to restrict development or incorporation of new features, nor to discourage innovative approaches.

Electroacoustics - Audiometric equipment - Instruments for the measurement of auditory brainstem responses

ICS
13.140; 17.140.50
CCS
N65
发布
2010-02-28
实施
2010-02-28

本规范规定了声级记录仪的计量特性、校准条件和校准方法。 本规范适用于声级记录仪的校准。

Calibration Specification for Sound Level Recorders

ICS
CCS
N65
发布
2010-01-05
实施
2010-04-05

本规范规定了采用电磁激励原理的高声压传声器校准器的计量特性、校准条件和校准方法。 本规范适用于采用电磁激励原理的高声压传声器校准器(以下简称校准器)的校准。

Calibration Specification for High Pressure Microphone Calibrators

ICS
CCS
N65
发布
2010-01-05
实施
2010-04-05

The audiometers covered in this specification are devices designed for use in determining the hearing threshold level of an individual in comparison with a chosen standard reference threshold level. This standard provides specifications and tolerances for pure tone, speech, and masking signals and describes the minimum test capabilities of different types of audiometers.

Specification for Audiometers

ICS
13.140
CCS
N65
发布
2010
实施