EN ISO 25424:2019
医疗器械的灭菌.低温蒸汽和甲醛.医疗器械灭菌过程的开发,确认和常规控制要求

Sterilization of health care products - Low temperature steam and formaldehyde - Requirements for development, validation and routine control of a sterilization process for medical devices (ISO 25424:2018)

2020-05

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 EN ISO 25424:2019 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “购买” 按钮开始采购(由第三方提供)。

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
EN ISO 25424:2019
发布
2019年
发布单位
欧洲标准化委员会
替代标准
EN ISO 25424:2019/prA1:2021
当前最新
EN ISO 25424:2019/A1:2022
 
 
适用范围
1.1 Inclusions 1.1.1 This document specifies requirements for the development, validation and routine control of a low temperature steam and formaldehyde (LTSF) sterilization process for medical devices using a mixture of low temperature steam and formaldehyde as sterilizing agent and which operates below ambient pressure. NOTE Although the scope of this document is limited to medical devices, it specifies requirements and provides guidance that can be applicable to other products and equipment. 1.1.2 This document is intended to be applied by process developers, manufacturers of sterilization equipment, manufacturers of medical devices to be sterilized and the organizations with responsibility for sterilizing medical devices (see ISO 14937:2009, Table E.1). 1.2 Exclusions 1.2.1 This document does not specify requirements for the development, validation and routine control of a process for inactivating the causative agents of spongiform encephalopathies such as scrapie, bovine spongiform encephalopathy and Creutzfeldt-Jakob disease. Specific recommendations have been produced in particular countries for the processing of materials potentially contaminated with these agents. NOTE See ISO 22442‑1, ISO 22442‑2 and ISO 22442‑3. 1.2.2 This document does not specify requirements for designating a medical device as "STERILE". Such requirements are given in EN 556‑1. 1.2.3 This document does not specify a quality management system for the control of all stages of production of medical devices. NOTE It is not a requirement of this document to have a complete quality management system during manufacture or reprocessing, but those elements of such a system that are required are normatively referenced at appropriate places in the text. Attention is drawn to the standards for quality management systems (see ISO 13485) that control all stages of production or reprocessing of medical devices including the sterilization process. Further guidance is given in E.4 of ISO 14937:2009. 1.2.4 This document does not specify requirements for occupational safety associated with the design and operation of LTSF sterilization facilities. NOTE 1 Safety requirements for sterilizers are specified in IEC 61010‑2‑040. NOTE 2 Attention is also drawn to the existence in some countries of regulations stipulating safety requirements. 1.2.5 This document does not cover analytical methods for determining levels or residues of formaldehyde and/or its reaction products. NOTE 1 Attention is drawn to EN 14180. NOTE 2 Attention is drawn to the possible existence in some countries of statutory regulations specifying limits for the level of formaldehyde residues on medical devices and products. 1.2.6 This document does not cover preparatory measures that might be necessary before sterilization such as cleaning, disinfection and packing. NOTE For reprocessable medical devices, the manufacturer(s) of these devices can supply information on the preparatory measures (see ISO 17664).

EN ISO 25424:2019相似标准


推荐

【注意】国内首部《过氧乙酸低温灭菌器通用技术标准》,12月31日起实施

本技术标准规定了过氧乙酸低温灭菌器(以下简称灭菌器)术语定义、要求、试验方法、标志与使用说明书、包装、运输、贮存,适用于过氧乙酸为灭菌介质,能够产生等离子体低温灭菌器,01过氧乙酸低温灭菌法规要求低温灭菌技术是指用来处理不耐受湿热医疗器械与物品一类灭菌方式总称,世界主流使用低温消毒灭菌技术有:过氧乙酸、环氧乙烷灭菌、过氧化氢低温等离子体灭菌低温蒸汽甲醛灭菌等。...

微生物实验灭菌方法相关知识

3、确认关键设备控制仪表在规定参数范围内能正常运行。4、采用被灭菌物品或模拟物品进行重复实验确认灭菌效果符合规定。5、完善文件记录,撰写验证报告。灭菌程序运行监控三1、 关键参数应在验证确定范围内:温度、压力、时间、湿度、灭菌气体浓度、辐照剂量等2、灭菌程序定期验证,时效不超过半年。3、灭菌设备或程序发生变更重新进行验证。...

微生物实验室灭菌方法!

2、确认灭菌设备技术资料齐全、安装正确,并能处于正常运行。3、确认关键设备控制仪表在规定参数范围内能正常运行。4、采用被灭菌物品或模拟物品进行重复实验确认灭菌效果符合规定。5、完善文件记录,撰写验证报告。三灭菌程序运行监控1、 关键参数应在验证确定范围内:温度、压力、时间、湿度、灭菌气体浓度、辐照剂量等2、灭菌程序定期验证,时效不超过半年。3、灭菌设备或程序发生变更重新进行验证。...

国标委发布296项国家标准 多项涉及检测

18278.1-2015医疗保健产品灭菌 湿热 第1部分:医疗器械灭菌过程开发确认常规控制要求GB 18278-2000, GB/T 20376-20062017-01-0189GB 18279.1-2015医疗保健产品灭菌 环氧乙烷 第1部分:医疗器械灭菌过程开发确认常规控制要求部分代替: GB 18279-20002017-01-0190GB/T 18279.2-2015医疗保健产品灭菌...