C41 医用超声、激光、高频仪器设备 标准查询与下载



共找到 351 条与 医用超声、激光、高频仪器设备 相关的标准,共 24

Ultrasonics.Physiotherapy systems.Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz (IEC 61689:2013); German version EN 61689;2013

ICS
11.040.60
CCS
C41
发布
2013-12
实施
2013-12-01

Imaging materials. Digital hard copy for medical imaging Methods of measuring permanence

ICS
37.100.01
CCS
C41
发布
2013-11-30
实施
2013-11-30

SN/T 1672的本部分规定了进出口医用超声诊断和理疗设备的抽样、检验及判定。本部分适用于进出口医用超声诊断和理疗设备的进出口检验。

Rules for the inspection of import and export medical equipment.Part 8:Ultrasonic diagnostic and physiotherapy equipment

ICS
CCS
C41
发布
2013-11-06
实施
2014-06-01

Standard means for the reporting of the acoustic output of medical diagnostic ultrasonic equipment (IEC 61157:2007 + A1:2013); German version EN 61157:2007 + A1:2013

ICS
11.040.55
CCS
C41
发布
2013-11
实施
2013-11-01

本标准规定了频率范围在0.5 MHz~15 MHz内的医用超声设备(以下简称设备)与探头频率特性的测试方法与相关参数的计算方法。本标准适用于工作在连续波、准连续波或脉冲波状态的各类医用超声设备与探头。

Methods of measuring the frequency of medical ultrasonic equipment and probe

ICS
11.040.50
CCS
C41
发布
2013-10-21
实施
2014-10-01

YY/T 0865的本部分规定了相关的水听器特性要求。本部分适用于:——采用压电敏感元件,设计用于测量超声设备产生的脉冲和连续波超声场的水听器;——用于在水中进行测量的水听器;——配接或未配接前置放大器的水听器。

Ultrasonics.Hydrophones.Part3:Properties of hydrophones for ultrasonic fields up to 40 MHz

ICS
11.040.50
CCS
C41
发布
2013-10-21
实施
2014-10-01

本标准规定了配接腔内探头B型超声诊断设备的术语和定义、测试条件以及试验方法。本标准适用于超声标称频率在1. 5 MHz~15. 0 MHz范围内,配接腔内探头的B型超声诊断设备(以下简称B超)。

Performance testing methods for B-mode ultrasonic diagnostic equipment with intra-cavity probe

ICS
11.040.50;11.040.55
CCS
C41
发布
2013-10-21
实施
2014-10-01

本标准规定了医用超声雾化器的技术要求、试验方法、检验规则以及标志、使用说明书。本标准适用于利用超声波对液态药物进行雾化的医用超声雾化器(以下简称“雾化器”),该产品主要供吸入治疗,也可用于环境的空气加湿。

Medical ultrasonic nebulizer

ICS
11.040.60
CCS
C41
发布
2013-10-02
实施
2014-10-01

Medical ultrasonic nebulizer

ICS
11.040.60
CCS
C41
发布
2013-10-02
实施
2014-10-01

Medical electrical equipment.Part 2-37: Particular requirements for the basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment

ICS
11.040.55;17.140.50
CCS
C41
发布
2013-09-01
实施

This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of HIGH INTENSITY THERAPEUTIC ULTRASOUND EQUIPMENT as defined in 201.3.218@ hereafter referred to as ME EQUIPMENT. This International Standard adds or replaces clauses listed in the IEC 60601-1 that are specific for HIGH INTENSITY THERAPEUTIC ULTRASOUND EQUIPMENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only@ or to ME SYSTEMS only@ the title and content of that clause or subclause will say so. If that is not the case@ the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS@ as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of the general standard. NOTE 1 See also 4.2 of the general standard. NOTE 2 As@ in HITU fields@ the acoustic waveform is expected to be extremely distorted due to non-linear propagation effects@ the ultrasonic measurements are to be made under quasi linear conditions and then extrapolated following procedures given in IEC/TS 62556. See also IEC/TS 61949 This standard can also be applied to: ?C therapeutic equipment for thrombolysis through exposure to high-intensity therapeutic ultrasound; ?C therapeutic equipment for the treatment of occluding feeding vessels through exposure to high-intensity focused ultrasound; ?C equipment intended to be used for relieving cancer pain due to bone metastases. This particular standard does not apply to: ? ULTRASOUND EQUIPMENT intended to be used for physiotherapy (use: IEC 60601-2-5 [1]2) and IEC 61689); ? ULTRASOUND EQUIPMENT intended to be used for lithotripsy (use: IEC 60601-2-36 [2]); ? ULTRASOUND EQUIPMENT intended to be used for dedicated hyperthermia devices; ? ULTRASOUND EQUIPMENT intended to be used for phacoemulsification. 2) Numbers in square brackets refer to the Bibibliography.

Medical electrical equipment - Part 2-62: particular requirements for the basic safety and essential performance of high intensity therapeutic ultrasound (HITU) equipment

ICS
11.040.01;11.040.60;17.140.50
CCS
C41
发布
2013-07
实施
2013-07-12

Ultrasonic hydrophones Part I: Measurement and characterization of medical ultrasonic fields below 40 MHz

ICS
CCS
C41
发布
2013-06-01
实施
2013-06-01

Ultrasonics. Physiotherapy systems. Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz

ICS
11.040.60
CCS
C41
发布
2013-05-31
实施
2013-05-31

This International Standard is applicable to ultrasonic equipment designed for physiotherapy containing an ultrasonic transducer generating continuous or quasi-continuous wave ultrasound in the frequency range 0@5 MHz to 5 MHz. This standard only relates to ultrasonic physiotherapy equipment employing a single plane non-focusing circular transducer per treatment head@ producing static beams perpendicular to the face of the treatment head. This standard specifies: ? methods of measurement and characterization of the output of ultrasonic physiotherapy equipment based on reference testing methods; ? characteristics to be specified by manufacturers of ultrasonic physiotherapy equipment based on reference testing methods; ? guidelines for safety of the ultrasonic field generated by ultrasonic physiotherapy equipment; ? methods of measurement and characterization of the output of ultrasonic physiotherapy equipment based on routine testing methods; ? acceptance criteria for aspects of the output of ultrasonic physiotherapy equipment based on routine testing methods. Therapeutic value and methods of use of ultrasonic physiotherapy equipment are not covered by the scope of this standard.

Ultrasonics - Physiotherapy systems - Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz

ICS
11.040.60
CCS
C41
发布
2013-02
实施
2013-02-28

Standard means for the reporting of the acoustic output of medical diagnostic ultrasonic equipment; Amendment 1

ICS
11.040.50;11.040.55;17.140.50
CCS
C41
发布
2013-01
实施
2013-01-30

Standard means for the reporting of the acoustic output of medical diagnostic ultrasonic equipment

ICS
11.040.50;11.040.55;17.140.50
CCS
C41
发布
2013-01
实施

IEC/TS 62791: Ultrasonics - Pulse-echo scanners - Low-echo sphere phantoms for performance testing of gray-scale medical ultrasound scanners applicable to a broad range of transducer types

ICS
11.040.55
CCS
C41
发布
2013-01
实施

IEC/TS 62556: Ultrasonics - Surgical systems - Specification and measurement of field parameters for High Intensity Therapeutic Ultrasound (HITU) transducers and systems

ICS
11.040.30;17.140.50
CCS
C41
发布
2012-11-01
实施

Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment

ICS
11.040.55;11.040.60
CCS
C41
发布
2012-10
实施

Medical electrical equipment -- Part 2-2: Particular requirements for the safety of high frequency surgical equipment

ICS
11.040.30
CCS
C41
发布
2012-07-01
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号