GB/T 19212.24-2020
Safety of transformers, reactors, power supply units and combinations thereof—Part 24:Particular requirements and test for transformers and power supply units for construction sites

Standard No.
GB/T 19212.24-2020
Language
Chinese
Release Date
2020
Published By
国家市场监督管理总局、中国国家标准化管理委员会
Lastest
GB/T 19212.24-2020
Replace
GB/T 19212.24-2005
Scope
This chapter of GB/T 19212.1-2016 is replaced by the following content: This part of GB/T 19212 specifies the safety of transformers for construction sites and power supply units with built-in transformers for construction sites. Transformers with electronic circuits are also included in this standard. Note 1: Safety requirements include electrical, temperature and mechanical aspects. Unless otherwise specified, the following "transformers" include transformers for construction sites and power supply units for transformers for construction sites. This section applies to stationary or mobile, single-phase or multi-phase, air-cooled (self-cooled or air-cooled), supporting or independent use and isolation or safety isolation dry-type transformers for construction sites. Windings can be encapsulated or non-encapsulated. The rated power supply voltage does not exceed AC 1000V, and the rated power frequency and internal operating frequency do not exceed 500 Hz. When this section is used in conjunction with GB/T 19212.17 switching power supply unit, it also applies to power supply units with an internal operating frequency exceeding 500 Hz. When the requirements of the two standards are inconsistent, the more stringent standard takes precedence. Rated output should not exceed: --- 25kVA, for single-phase transformers; --- 40kVA, for multi-phase transformers. If the purchaser and the manufacturer agree otherwise, this section also applies to transformers with unlimited rated output. Note 2: This scope does not include transformers intended for distribution networks. The no-load output voltage and rated output voltage of isolation transformers for construction sites and power supply units with built-in isolation transformers for construction sites exceed AC 50V but do not exceed AC 250V. The no-load output voltage and rated output voltage of safety isolation transformers for construction sites and power supply units with built-in safety isolation transformers for construction sites shall not exceed AC 50V. Note 3: This standard applies to transformers used as power supplies in places specified in GB/T 16895.7. GB/T16895.7 also stipulates the protective measures for grounding with the middle point of the output winding or the star connection point. The transformers and power supply units covered by this standard are used in installation regulations or equipment specifications for protective purposes. When transformers or power supply units are incorporated into low-voltage switchgear and control equipment for construction sites specified in GB/T 7251.4, the additional requirements of GB/T 7251.4 also apply to the complete equipment. Note 4: For transformers filled with liquid media or powder materials (such as sand), additional requirements are under consideration. Note 5: Pay attention to the following instructions: --- Protective measures to prevent the enclosure and components inside the enclosure from external influences such as mold, pests, termites, solar radiation and freezing should also be considered; ---Transportation and storage of transformers and power supply units Different conditions of operation and operation should also be considered; — for transformers intended to be used in special environments, such as tropical environments, additional requirements may be adopted in accordance with other applicable standards and national regulations. Note 6: With the development of transformer technology in the future, it may be necessary to increase the upper limit of the frequency. Until then, this section can be used as a guideline. 1 GB/T19212.24—2020

GB/T 19212.24-2020 history

  • 2020 GB/T 19212.24-2020 Safety of transformers, reactors, power supply units and combinations thereof—Part 24:Particular requirements and test for transformers and power supply units for construction sites
  • 2005 GB/T 19212.24-2005 Safety of power transformers, power supply units and similar devices -- Part 24: Particular requirements for transformers for construction sites

GB/T 19212.24-2020 -All Parts

GB/T 19212.1-2016 Safety of transformers, reactors,power supply units and combinations thereof—Part 1: General requirements and tests GB/T 19212.10-2014 Safety of transformers, reactors,power supply units and combinations thereof.Part 10:Particular requirements and tests for transformers and power supply units for class Ⅲ handlamps for tungsten filament lamps GB/T 19212.11-2020 Safety of transformers, reactors, power supply units and combinations thereof—Part 11: Particular requirements and tests for separating transformers with high insulation level and separating transformers with output voltages exceeding 1 000 V GB/T 19212.13-2019 Safety of transformers,reactors,power supply units and combination thereof—Part 13: Particular requirements and tests for constant voltage transformers and power supply units for constant voltage GB/T 19212.14-2012 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 14: Particular requirements and tests for auto transformers and power supply units incorporating auto transformers GB/T 19212.15-2016 Safety of transformers, reactors, power supply units and combinations thereof—Part 15: Particular requirements and tests for variable transformers and power supply units incorporating variable transformers GB/T 19212.16-2017 Safety of transformers,reactors,power supply units and combinations thereof—Part 16: Particular requirements and tests for isolating transformers for the supply of medical locations GB/T 19212.17-2019 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V—Part 17: Particular requirements and tests for switch mode power supply units and transformers for switch mode power supply units GB/T 19212.2-2012 Safety of power transformers, power supplies, reactors and similar products - Part 2: Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications GB/T 19212.20-2008 Safety of power transformers, power supply units and similar - Part 20: Particular requirements for perturbation attenuation transformers GB/T 19212.21-2014 Safety of transformers,reactors,power supply units and combinations thereof.Part 21:Particular requirements and tests for small reactors GB/T 19212.24-2020 Safety of transformers, reactors, power supply units and combinations thereof—Part 24:Particular requirements and test for transformers and power supply units for construction sites GB/T 19212.27-2017 Safety of transformers,reactors,power supply units and combinations thereof—Part 27: Particular requirements and tests for transformers and power supply units all for saving energy and other purposes GB/T 19212.3-2012 Safety of power transformers, power supplies, reactors and similar products - Part 3: Particular requirements and tests for control transformers and power supplies incorporating control transformers GB/T 19212.4-2016 Safety of transformers, reactors, power supply units and combinations thereof—Part 4: Particular requirements and tests for ignition transformers for gas and oil burners GB/T 19212.5-2011 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100V - Part 5: Particular requirements and tests for isolating transformers and power supply units incorporating isolating transformers GB/T 19212.6-2013 Safety of transformers, reactors, power supply units and combinations thereof―Part 6: Particular requirements and test for transformer for shavers, power supply units for shavers snd shaver supply units GB/T 19212.7-2012 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 7: Particular requirements and test for safety isolating transformers and power supply units incorporating saftey isolating transformers GB/T 19212.8-2012 Safety of power transformers, power supplies, reactors and similar products - Part 8:Particular requirements and tests for transformers and power supplies for toys GB/T 19212.9-2016 Safety of transformers, reactors, power supply units and combinations thereof—Part 9: Particular requirements and tests for transformers and power supply units for bells and chimes