GB/T 19212.10-2014
- Replace
-
GB 19212.10-2007
- Scope
- This chapter of GB 19212.1-2008 is replaced with the following content: This part of GB 19212 specifies the safety requirements for transformers for class III portable tungsten lamps and power supply units with built-in transformers for class III portable tungsten lamps. Transformers with electronic circuits are also included in this standard. Unless otherwise specified, the following "transformers" include transformers for class III portable tungsten lamps and power supply units with built-in transformers for class III portable tungsten lamps. This section applies to stationary or mobile, single-phase, air-cooled (self-cooled or air-cooled), independent or supporting dry-type transformers. Its windings can be encapsulated or non-encapsulated. This standard applies to transformers and power supply units (linear) with an internal operating frequency not exceeding 500 Hz. This section is used in conjunction with GB 19212.17 switching power supply unit, and also applies to power supply units with an internal operating frequency exceeding 500 Hz. When the requirements of the two standards are inconsistent, the more stringent standard takes precedence. The rated power supply voltage does not exceed AC 1000 V, and the rated power supply frequency and internal operating frequency do not exceed 500 Hz. Class III transformers for portable tungsten lamps have the following additional characteristics: -- no-load output voltage and rated output voltage do not exceed AC 50 V or ripple-free DC 120 V; -- no-load voltage and rated output voltage are only small difference. Rated output should not exceed: --10 kVA. This section does not apply to external circuits and their components intended to be connected to the input and output terminals of the transformer. Transformers included in this section may be used when double insulation or reinforced insulation between circuits is required by installation procedures or final product standards.
GB/T 19212.10-2014 Referenced Document
- GB 19212.1-2008 Safety of power transformers, power supplies,reactors and similar products.Part 1: General requirements and tests
GB/T 19212.10-2014 history
- 2014 GB 19212.10-2014 Safety of transformers, reactors,power supply units and combinations thereof.Part 10:Particular requirements and tests for transformers and power supply units for class Ⅲ handlamps for tungsten filament lamps
- 2007 GB 19212.10-2007 Safety of power transformers, power supply units and similar devices Part 10: Particular requirements for transformers for class Ⅲ handlamps for tungsten filament lamps
- 1991 GB 13028-1991 Isolating transformers and safety isolating transformers--Requirements
GB/T 19212.10-2014 Safety of transformers, reactors,power supply units and combinations thereof.Part 10:Particular requirements and tests for transformers and power supply units for class Ⅲ handlamps for tungsten filament lamps has been changed from GB 19212.10-2007 Safety of power transformers, power supply units and similar devices Part 10: Particular requirements for transformers for class Ⅲ handlamps for tungsten filament lamps.