GB/T 19212.10-2014
Safety of transformers, reactors,power supply units and combinations thereof.Part 10:Particular requirements and tests for transformers and power supply units for class Ⅲ handlamps for tungsten filament lamps (English Version)

GB/T 19212.10-2014
Standard No.
GB/T 19212.10-2014
Language
Chinese, Available in English version
Release Date
2014
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Latest
GB/T 19212.10-2014
Replace
GB 19212.10-2007
Scope
This chapter of GB 19212.1-2008 is replaced with the following content: This part of GB 19212 specifies the safety requirements for transformers for class III portable tungsten lamps and power supply units with built-in transformers for class III portable tungsten lamps. Transformers with electronic circuits are also included in this standard. Unless otherwise specified, the following "transformers" include transformers for class III portable tungsten lamps and power supply units with built-in transformers for class III portable tungsten lamps. This section applies to stationary or mobile, single-phase, air-cooled (self-cooled or air-cooled), independent or supporting dry-type transformers. Its windings can be encapsulated or non-encapsulated. This standard applies to transformers and power supply units (linear) with an internal operating frequency not exceeding 500 Hz. This section is used in conjunction with GB 19212.17 switching power supply unit, and also applies to power supply units with an internal operating frequency exceeding 500 Hz. When the requirements of the two standards are inconsistent, the more stringent standard takes precedence. The rated power supply voltage does not exceed AC 1000 V, and the rated power supply frequency and internal operating frequency do not exceed 500 Hz. Class III transformers for portable tungsten lamps have the following additional characteristics: -- no-load output voltage and rated output voltage do not exceed AC 50 V or ripple-free DC 120 V; -- no-load voltage and rated output voltage are only small difference. Rated output should not exceed: --10 kVA. This section does not apply to external circuits and their components intended to be connected to the input and output terminals of the transformer. Transformers included in this section may be used when double insulation or reinforced insulation between circuits is required by installation procedures or final product standards.

GB/T 19212.10-2014 Referenced Document

  • GB 19212.1-2008 Safety of power transformers, power supplies,reactors and similar products.Part 1: General requirements and tests

GB/T 19212.10-2014 history

  • 2014 GB 19212.10-2014 Safety of transformers, reactors,power supply units and combinations thereof.Part 10:Particular requirements and tests for transformers and power supply units for class Ⅲ handlamps for tungsten filament lamps
  • 2007 GB 19212.10-2007 Safety of power transformers, power supply units and similar devices Part 10: Particular requirements for transformers for class Ⅲ handlamps for tungsten filament lamps
  • 1991 GB 13028-1991 Isolating transformers and safety isolating transformers--Requirements

GB/T 19212.10-2014 Safety of transformers, reactors,power supply units and combinations thereof.Part 10:Particular requirements and tests for transformers and power supply units for class Ⅲ handlamps for tungsten filament lamps has been changed from GB 19212.10-2007 Safety of power transformers, power supply units and similar devices Part 10: Particular requirements for transformers for class Ⅲ handlamps for tungsten filament lamps.


GB/T 19212.10-2014 -All Parts

GB/T 19212.1-2023 Safety of transformers, reactors, power supply units and combinations thereof Part 1: General requirements and tests GB/T 19212.10-2014 Safety of transformers, reactors,power supply units and combinations thereof.Part 10:Particular requirements and tests for transformers and power supply units for class Ⅲ handlamps for tungsten filament lamps GB/T 19212.11-2020 Safety of transformers, reactors, power supply units and combinations thereof—Part 11: Particular requirements and tests for separating transformers with high insulation level and separating transformers with output voltages exceeding 1 000 V GB/T 19212.13-2019 Safety of transformers,reactors,power supply units and combination thereof—Part 13: Particular requirements and tests for constant voltage transformers and power supply units for constant voltage GB/T 19212.14-2012 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 14: Particular requirements and tests for auto transformers and power supply units incorporating auto transformers GB/T 19212.15-2016 Safety of transformers, reactors, power supply units and combinations thereof—Part 15: Particular requirements and tests for variable transformers and power supply units incorporating variable transformers GB/T 19212.16-2017 Safety of transformers,reactors,power supply units and combinations thereof—Part 16: Particular requirements and tests for isolating transformers for the supply of medical locations GB/T 19212.17-2019 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V—Part 17: Particular requirements and tests for switch mode power supply units and transformers for switch mode power supply units GB/T 19212.2-2012 Safety of power transformers, power supplies, reactors and similar products - Part 2: Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications GB/T 19212.20-2008 Safety of power transformers, power supply units and similar - Part 20: Particular requirements for perturbation attenuation transformers GB/T 19212.21-2014 Safety of transformers,reactors,power supply units and combinations thereof.Part 21:Particular requirements and tests for small reactors GB/T 19212.24-2020 Safety of transformers, reactors, power supply units and combinations thereof—Part 24:Particular requirements and test for transformers and power supply units for construction sites GB/T 19212.27-2017 Safety of transformers,reactors,power supply units and combinations thereof—Part 27: Particular requirements and tests for transformers and power supply units all for saving energy and other purposes GB/T 19212.3-2012 Safety of power transformers, power supplies, reactors and similar products - Part 3: Particular requirements and tests for control transformers and power supplies incorporating control transformers GB/T 19212.4-2016 Safety of transformers, reactors, power supply units and combinations thereof—Part 4: Particular requirements and tests for ignition transformers for gas and oil burners GB/T 19212.5-2011 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100V - Part 5: Particular requirements and tests for isolating transformers and power supply units incorporating isolating transformers GB/T 19212.6-2013 Safety of transformers, reactors, power supply units and combinations thereof―Part 6: Particular requirements and test for transformer for shavers, power supply units for shavers snd shaver supply units GB/T 19212.7-2012 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 7: Particular requirements and test for safety isolating transformers and power supply units incorporating saftey isolating transformers GB/T 19212.8-2012 Safety of power transformers, power supplies, reactors and similar products - Part 8:Particular requirements and tests for transformers and power supplies for toys GB/T 19212.9-2016 Safety of transformers, reactors, power supply units and combinations thereof—Part 9: Particular requirements and tests for transformers and power supply units for bells and chimes



Copyright ©2007-2024 ANTPEDIA, All Rights Reserved