GB/T 19212.11-2020
Safety of transformers, reactors, power supply units and combinations thereof—Part 11: Particular requirements and tests for separating transformers with high insulation level and separating transformers with output voltages exceeding 1 000 V (English Version)

GB/T 19212.11-2020
Standard No.
GB/T 19212.11-2020
Language
Chinese, Available in English version
Release Date
2020
Published By
国家市场监督管理总局、中国国家标准化管理委员会
Latest
GB/T 19212.11-2020
Scope
This chapter of GB/T 19212.1-2016 is replaced with the following content: This part of GB/T 19212 specifies the safety requirements for high insulation level separation transformers and separation transformers with an output voltage exceeding 1000 V. Transformers with electronic circuits are also included in this standard. Note 1: Safety requirements include electrical, temperature and mechanical aspects. Unless otherwise specified, the following "transformers" include high insulation level separating transformers and separating transformers with an output voltage exceeding 1000 V a.c. or 1500 V d.c. This section applies to stationary or mobile, single-phase or multi-phase, air-cooled (natural cooling or forced cooling), independent or supporting dry-type transformers. Its windings can be encapsulated or non-encapsulated. This standard applies to transformers and power supply units (linear) with an internal operating frequency not exceeding 500 Hz. When this section is used in conjunction with GB/T 19212.17 switching power supply unit, it also applies to power supply units with an internal operating frequency exceeding 500 Hz. When the requirements of the two standards are inconsistent, the more stringent standard takes precedence. This section applies to rated power supply voltage not exceeding AC 1000V, rated power frequency and internal operating frequency not exceeding 500 Hz. This section applies to rated output not exceeding: --- 25kVA for single-phase transformers; --- 40kVA for multi-phase transformers. If the purchaser and the manufacturer agree otherwise, this section also applies to transformers that do not limit the rated output. This section applies to the no-load output voltage or rated output voltage: --- for high insulation level separation transformers not exceeding AC 1000V or DC 1500V; --- for separation transformers with output voltage exceeding 1000V, exceeding AC 1000V or DC 1500V and not exceeding Exceeding AC or DC 15000V. This part does not apply to: --- Transformers covered by GB/T1094.11; --- Neon lamp transformers covered by GB/T19149; --- IEC61347 2

GB/T 19212.11-2020 Referenced Document

  • GB/T 19212.1-2016 Safety of transformers, reactors,power supply units and combinations thereof—Part 1: General requirements and tests
  • GB/T 19212.17 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V—Part 17: Particular requirements and tests for switch mode power supply units and transformers for switch mode power supply units

GB/T 19212.11-2020 history

  • 2020 GB/T 19212.11-2020 Safety of transformers, reactors, power supply units and combinations thereof—Part 11: Particular requirements and tests for separating transformers with high insulation level and separating transformers with output voltages exceeding 1 000 V

GB/T 19212.11-2020 -All Parts

GB/T 19212.1-2023 Safety of transformers, reactors, power supply units and combinations thereof Part 1: General requirements and tests GB/T 19212.10-2014 Safety of transformers, reactors,power supply units and combinations thereof.Part 10:Particular requirements and tests for transformers and power supply units for class Ⅲ handlamps for tungsten filament lamps GB/T 19212.11-2020 Safety of transformers, reactors, power supply units and combinations thereof—Part 11: Particular requirements and tests for separating transformers with high insulation level and separating transformers with output voltages exceeding 1 000 V GB/T 19212.13-2019 Safety of transformers,reactors,power supply units and combination thereof—Part 13: Particular requirements and tests for constant voltage transformers and power supply units for constant voltage GB/T 19212.14-2012 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 14: Particular requirements and tests for auto transformers and power supply units incorporating auto transformers GB/T 19212.15-2016 Safety of transformers, reactors, power supply units and combinations thereof—Part 15: Particular requirements and tests for variable transformers and power supply units incorporating variable transformers GB/T 19212.16-2017 Safety of transformers,reactors,power supply units and combinations thereof—Part 16: Particular requirements and tests for isolating transformers for the supply of medical locations GB/T 19212.17-2019 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V—Part 17: Particular requirements and tests for switch mode power supply units and transformers for switch mode power supply units GB/T 19212.2-2012 Safety of power transformers, power supplies, reactors and similar products - Part 2: Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications GB/T 19212.20-2008 Safety of power transformers, power supply units and similar - Part 20: Particular requirements for perturbation attenuation transformers GB/T 19212.21-2014 Safety of transformers,reactors,power supply units and combinations thereof.Part 21:Particular requirements and tests for small reactors GB/T 19212.24-2020 Safety of transformers, reactors, power supply units and combinations thereof—Part 24:Particular requirements and test for transformers and power supply units for construction sites GB/T 19212.27-2017 Safety of transformers,reactors,power supply units and combinations thereof—Part 27: Particular requirements and tests for transformers and power supply units all for saving energy and other purposes GB/T 19212.3-2012 Safety of power transformers, power supplies, reactors and similar products - Part 3: Particular requirements and tests for control transformers and power supplies incorporating control transformers GB/T 19212.4-2016 Safety of transformers, reactors, power supply units and combinations thereof—Part 4: Particular requirements and tests for ignition transformers for gas and oil burners GB/T 19212.5-2011 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100V - Part 5: Particular requirements and tests for isolating transformers and power supply units incorporating isolating transformers GB/T 19212.6-2013 Safety of transformers, reactors, power supply units and combinations thereof―Part 6: Particular requirements and test for transformer for shavers, power supply units for shavers snd shaver supply units GB/T 19212.7-2012 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 7: Particular requirements and test for safety isolating transformers and power supply units incorporating saftey isolating transformers GB/T 19212.8-2012 Safety of power transformers, power supplies, reactors and similar products - Part 8:Particular requirements and tests for transformers and power supplies for toys GB/T 19212.9-2016 Safety of transformers, reactors, power supply units and combinations thereof—Part 9: Particular requirements and tests for transformers and power supply units for bells and chimes