GB 1094.1-2013
Power transformers.Part 1: General (English Version)

GB 1094.1-2013
Standard No.
GB 1094.1-2013
Language
Chinese, Available in English version
Release Date
2013
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Latest
GB 1094.1-2013
Replace
GB 1094.1-1996
Scope
This part of GB 1094 applies to three-phase and single-phase transformers (including autotransformers), but does not include some small and special transformers, such as: --Single-phase transformers with a rated capacity of less than 1 kVA and three-phase transformers with a rated capacity of 5 kVA ;--Transformers with rated voltage of all windings not higher than 1 000 V;--Transformers;--Electric locomotive traction transformers;--Starting transformers;--Test transformers;--Welding transformers; ;--Transformers for deep water (immersion). When there is no corresponding standard for certain types of transformers (especially industrial special transformers with all winding voltages not higher than 1 000 V), this Part can be applied in whole or in part. This section does not deal with the requirements for transformers installed in public places. For transformers and reactors with relevant standards, this section only applies to the scope of content that is clearly mentioned by their product standards and can be referred to each other. These products (standards) include: -- Reactor (GB/T 1094.6); -- Dry-type transformer (GB 1094.11); -- Self-protected transformer (IEC 60076-13); -- Gas-filled power transformer (IEC 60076- 15);--Transformers for wind power generation (GB 1094.16);--Traction transformers and traction reactors (GB/T 25120);--Industrial converter transformers (GB/T 18494.1);--Converter transformers for HVDC (GB/T 18494.2). Several provisions or recommendations in this section refer to the agreement that some alternatives, additional technical solutions or procedures need to be reached. Such an agreement needs to be reached between the manufacturer and the user. Questions should be asked early on and agreements should be included in technical specifications.

GB 1094.1-2013 Referenced Document

  • GB 10230.1 Tap-changers- Part 1: Performance requirements and test methods
  • GB 1094.11 Power transformers- Part 11: Dry-type transformers
  • GB 1094.2 Power transformers.Part 2:Temperature rise for liquid-immersed transformers
  • GB 1094.3 Power transformers Part 3: Insulation levels,dielectric tests and external clearances in air
  • GB 1094.5 Power transformers.Part 5:Ability to withstand short circuit
  • GB 2536 Fluids for electrotechnical applications.Unused mineral insulating oils for transformers and switchgear
  • GB/T 1094.10 Power transformers— Part 10:Determination of sound levels*2022-10-14 Update
  • GB/T 19001 Quality Management System Requirements*2017-07-01 Update
  • GB/T 2521 Cold-rolled grain-oriented and non-oriented electrical steel strip(sheet)
  • GB/T 2900.15 Electrotechnical terminology. Transformer, instrument transformer, voltage regulator and reactor
  • GB/T 4109 Insulated bushings for alternating voltages above 1 000 V*2022-03-09 Update
  • GB/T 4798.4 Classification of environmental conditions—Classification of groups of environmental parameters and their severities—Part 4: Stationary use at non-weatherprotected locations*2023-05-23 Update

GB 1094.1-2013 history


GB 1094.1-2013 -All Parts




Copyright ©2007-2024 ANTPEDIA, All Rights Reserved