GB/T 13539.2-2015
Low-voltage fuses.Part 2:Supplementary requirements for fuses for use by authorized persons(fuses mainly for industrial application).Examples of standardized systems of fuses A to K (English Version)

GB/T 13539.2-2015
Standard No.
GB/T 13539.2-2015
Language
Chinese, Available in English version
Release Date
2015
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Latest
GB/T 13539.2-2015
Replace
GB/T 13539.2-2008
Scope
Professional fuses are generally designed for use in installations where only professional personnel can access and replace the fuse. Professional fuses are generally designed for use in installations where only professional personnel can access and replace the fuse. Unless otherwise specified in this part of GB/T 13539, fuses used by professionals who meet the requirements of the following fuse systems shall also comply with the requirements of IEC 60269-1. This part consists of the following fuse systems, each of which refers to a specific example of a standard fuse for professional use. -- Fuse system A: knife contact fuse (NH fuse system); -- Fuse system B: knife contact fuse with striker (NH fuse system); -- Fuse system C : Strip fuse base (NH fuse system); -- Fuse system D: Busbar-mounted fuse base (NH fuse system); -- Fuse system E: Bolt connection fuse (BS bolt connection fuse system); -- Fuse system F: cylindrical cap fuse (NF cylindrical cap fuse system); -- Fuse system G: offset contact knife fuse (BS clamping fuse system); --Fuse system H: "gD" and "gN" characteristic fuses (J, T and L time-delay and non-delay fuse types); --Fuse system I: gU wedge-shaped contact fuse ; -- Fuse system J: "CC class gD" and "CC class gN" characteristic fuses (CC class time-delay and non-time-delay fuse types); -- Fuse system K: Bolt-connected knife-type contacts gK fuse-links (main fuse-links for high current ratings from 1 250 A to 4 800 A).

GB/T 13539.2-2015 Referenced Document

  • GB 13539.1-2015 Low-voltage fuses.Part 1:General requirements
  • GB 17464-2012 Connecting devices.Electrical copper conductors.Safety requirements for screw-type and screwless-type clamping units.General requirements and particular requirements for clamping units for conductors from 0.2mm² up to 35mm²(included)
  • GB/T 16935.1-2008 Insulation coordination for equipment within low-voltage systems.Part 1:Principles,requirements and tests
  • GB/T 20636-2006 Connecting device-Electrical copper conductors-Safety requirements for screw-type and screwless-type clamping units Particular requirements for conductors above 35mm up to 300mm
  • GB/T 4207-2012 Method for the determination of the proof and the comparative tracking indices of solid insulating materials
  • GB/T 9789-2008 Metallic and other non-organic coatings.Sulfur dioxide test with general condensation of moisture
  • IEC 60999 Connecting Devices - Safety Requirements for Screw-Type and Screwless-Type Clamping Units for Electrical Copper Conductors (Edition 1.0; CENELEC EN 60999: 1993; Corrigendum-1995)

GB/T 13539.2-2015 history

  • 2015 GB/T 13539.2-2015 Low-voltage fuses.Part 2:Supplementary requirements for fuses for use by authorized persons(fuses mainly for industrial application).Examples of standardized systems of fuses A to K
  • 2009 GB/T 13539.2-2008 Low-voltage fuses-Part 2: Supplementary requirements for fuses used by professionals (fuses mainly used in industry) Examples of standardized fuse systems A to I
  • 2002 GB/T 13539.2-2002 Low-voltage fuses-Part 2: Supplementary requirements for fuses for use by authorized persons(fuses mainly for industrial application)

GB/T 13539.2-2015 -All Parts