29.080.20 套管 标准查询与下载



共找到 210 条与 套管 相关的标准,共 14

Bushings above 1 kV up to 36 kV and from 250 A to 3,15 kA for liquid filled transformers - Constructional details of components

ICS
29.080.20
CCS
K15
发布
2005-06
实施

Cable glands for electrical installations; German version EN 50262:1998 + A1:2001 + A2:2004

ICS
29.080.20
CCS
K47
发布
2005-05
实施
2005-05-01

This standard provides requirements and tests for the construction and performance of cable glands. This standard covers complete glands as supplied by the manufacturer or supplier, but not parts of cable glands.

Cable glands for electrical installations

ICS
29.080.20
CCS
发布
2005-04-23
实施
2005-04-23

Applies to power apparatus bushings that have basic impulse insulation levels of 110 kV and above for use as components of oil-filled transformers and oil-filled reactors. Defines the special terms used, service conditions, rating, general requirements, and test procedure for apparatus bushings.

Standard General Requirements and Test Procedure for Power Apparatus Bushings

ICS
29.080.20
CCS
K15
发布
2005-04-13
实施

Bushings for d.c. application (IEC 62199:2004); German version EN 62199:2004

ICS
29.080.20
CCS
K48
发布
2005-04
实施
2005-04-01

Metric cable glands for electrical installations

ICS
29.080.20
CCS
发布
2005-03-14
实施
2005-03-14

Cable glands for electrical installations.

ICS
29.080.20
CCS
K47
发布
2005-03-01
实施
2005-03-20

Corrects errors in the base standard.

Standard Requirements, Terminology, and Test Code for Bushings for DC Applications - Corrigendum 1

ICS
29.080.20
CCS
K15
发布
2005
实施

IEEE C 57.19.03 Technical Corrigenda

Requirements, Terminology and Test Code for Bushings for DC Applications; Corrigendum 1

ICS
29.080.20
CCS
K15
发布
2005
实施

Bushings for d.c. application (IEC 62199:2004)

ICS
29.080.20
CCS
发布
2004-12-29
实施
2004-12-29

Outdoor bushings for 24 kV and 36 kV and for 5 kA and 8 kA, for liquid filled transformers.

ICS
29.080.20
CCS
K48
发布
2004-12-01
实施
2004-12-05

Bushings for d.c. application.

ICS
29.080.20
CCS
K48
发布
2004-11-01
实施
2004-11-05

This International Standard applies to outdoor and indoor bushings of any voltage used on d.c. systems, of capacitance graded or gas insulated types for use as components of oil-filled converter transformers and smoothing reactors, as well as air-to-air d.c. bushings. This standard does not apply to the following: - Cable terminations (potheads) - Bushings for instrument transformers - Bushings for test transformers - Bushings applied with gaseous insulation (other than air at atmospheric pressure) external to the bushing - Bushings for industrial application - Bushings for traction application. This standard makes reference to IEC 60137 for general terms a

Bushings for d.c. application

ICS
29.080.20
CCS
发布
2004-09-08
实施
2004-08-16

This International Standard applies to outdoor and indoor bushings of any voltage used on d.c. systems, of capacitance graded or gas insulated types for use as components of oil-filled converter transformers and smoothing reactors, as well as air-to-air d.c. bushings. This standard does not apply to the following: · cable terminations (potheads); · bushings for instrument transformers; · bushings for test transformers; · bushings applied with gaseous insulation (other than air at atmospheric pressure) external to the bushing; · bushings for industrial application; · bushings for traction application. This standard makes reference to IEC 60137 for general terms and conditions and defines the special terms used, operating conditions, ratings, test procedures as well as general mechanical and electrical requirements for bushings for d.c. application. Where applicable, reference can also be made to IEC 61462 for composite insulators - hollow insulators for use in outdoor and indoor electrical equipment and to IEC 62155 for hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V.

Bushings for D.C. application

ICS
29.080.20
CCS
K47
发布
2004-08-03
实施
2004-08-03

Applies to outdoor and indoor bushings of any voltage used on d.c. systems, of capacitance graded or gas insulated types for use as components of oil-filled converter transformers and smoothing reactors, as well as air-to-air d.c. bushings.

Bushings for d.c. application

ICS
29.080.20
CCS
K15
发布
2004-05-01
实施
2014-08-05

Insulated bushings for alternating voltages above 1 000 V.

ICS
29.080.20
CCS
K48
发布
2004-04-01
实施
2004-04-05

Busbar bushings up to 1 kV and from 1,25 kA to 5 kA, for liquid filled transformers; German version EN 50387:2002

ICS
29.080.20
CCS
K41
发布
2004-01
实施
2004-01-01

This standard is applicable to ceramic insulated bushings for rated voltages up to 1 kV, rated currents from 250 A up to 5 kA and frequencies from 15 Hz up to 60 Hz for insulating liquid filled transformers.#,,#

Bushings up to 1 kV and from 250 A to 5 kA, for liquid filled transformers; German version EN 50386:2002

ICS
29.080.20
CCS
K41
发布
2004-01
实施
2004-01-01

This International Standard specifies the characteristics and tests for insulated bushings. This standard is applicable to bushings, as defined in Clause 3, intended for use in electrical apparatus, machinery, transformers, switchgear and installations for three-phase alternating current systems, having highest voltage for equipment above 1000 V and power frequencies of 15 Hz up to and including 60 Hz. Subject to special agreement between purchaser and supplier, this standard may be applied, in part or as a whole, to the following: □ bushings used in other than three-phase systems; □ bushings for high-voltage, direct current systems; □ bushings for testing transformers; □ terminals for power cables (potheads); □ bushings for capacitors. Special requirements and tests for transformer bushings in this standard apply also to reactor bushings. This standard is applicable to bushings made and sold separately. Bushings which are a part of an apparatus and which cannot be tested according to this standard, should be tested with the apparatus of which they form part.

Insulated bushings for alternating voltages above 1 000 V

ICS
29.080.20
CCS
发布
2004
实施

This International Standard specifies the characteristics and tests for insulated bushings. This standard is applicable to bushings, as defined in Clause 3, intended for use in electrical apparatus, machinery, transformers, switchgear and installations for three-phase alternating current systems, having highest voltage for equipment above 1 000 V and power frequencies of 15 Hz up to and including 60 Hz. Subject to special agreement between purchaser and supplier, this standard may be applied, in part or as a whole, to the following: · bushings used in other than three-phase systems; · bushings for high-voltage, direct current systems; · bushings for testing transformers; · terminals for power cables (potheads); · bushings for capacitors. Special requirements and tests for transformer bushings in this standard apply also to reactor bushings. This standard is applicable to bushings made and sold separately. Bushings which are a part of an apparatus and which cannot be tested according to this standard, should be tested with the apparatus of which they form part.

Insulated bushings for alternating voltages above 1000 V

ICS
29.080.20
CCS
K15
发布
2003-11-25
实施
2003-11-25



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved