Construction of bearing base electronic. The management cabinets, meet the standards of the series IEC 60297 and IEC 60917. Part 1. Design Guide. Sizes of interface and position on the thermo-electric systems of cooling (effect of Peltier)

ICS
31.240
CCS
L85
发布
2016
实施
2017-03-01

Construction of bearing base electronic. The management cabinets, meet the standards of the series IEC 60297 and IEC 60917. Part 3. Design Guide. Method of estimation of thermoelectric cooling systems (Peltier effect)

ICS
31.240
CCS
L85
发布
2016
实施
2017-03-01

Mechanical structures for electronic equipment -- Tests for IEC 60917 and IEC 60297 -- Part 3: Electromagnetic shielding performance tests for cabinets and subracks

ICS
31.240
CCS
L94
发布
2015-11-20
实施

Mechanical structures for electronic equipment -- Dimensions of mechanical structures of the 482.6 mm (19 in) series -- Part 3-100: Basic dimensions of front panels, subracks, chassis, racks and cabinets

ICS
31.240
CCS
L94
发布
2015-11-20
实施

Mechanical structures for electronic equipment -- Tests for IEC 60917 and IEC 60297 series -- Part 1: Environmental requirements, test set-up and safety aspects for cabinets, racks, subracks and chassis under indoor conditions

ICS
31.240
CCS
L94
发布
2015-11-20
实施

Mechanical structures for electronic equipment -- Tests for IEC 60917 and IEC 60297 -- Part 2: Seismic tests for cabinets and racks

ICS
31.240
CCS
L94
发布
2015-11-20
实施

This part of IEC 60297 specifies dimensions and physical properties of chassis and associated printed boards in order to provide mechanical and environmental integrity for embedded computing devices. They are used in various applications such as machine control, medical, transportation, aerospace and telecommunication, typically based on single board computers. For the easy definition of the suitable chassis and associated single board dimensions, this standard is based on a structural grid of 44,45 mm (1,75 in).

Mechanical structures for electrical and electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-109: Dimensions of chassis for embedded computing devices

ICS
31.240
CCS
L94
发布
2015-11
实施

This part of IEC 60297 covers the connector dependent interface dimensions for subracks and plug-in units in accordance with subracks of IEC 60297-3-101. In this part of IEC 60297, the two-part connectors of the series IEC 60603-2, IEC 61076-4-101, IEC 61076-4-113 are concerned. Since the connector specific standards contain the dimensions of the connectors only, it is the intention of this part of IEC 60297 to introduce the related subrack and plug-in unit interface dimensions if the connectors mentioned are applied. This standard will also provide dimensional guidelines for the implementation of other connectors by definition of the relationship between subrack mounting pitches and the position of board- type plug-in units and backplanes.

Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-104: Connector dependent interface dimensions of subracks and plug-in units

ICS
31.240
CCS
发布
2015-09-03
实施

This part of IEC 60917 provides additional dimensions for a modular range of subracks and associated plug-in units based on IEC 60917-2-2. A typical subrack consists of a frame design with mounting dimensions for installation into racks or cabinets in accordance with IEC 60917-2-1. The aperture dimensions of a subrack are specified in order to meet the mounting dimensions of front plug-in units. This part of IEC 60917 comprises – additional dimensions for subracks and subrack associated plug-in units with injector/extractor handle; – dimensions for basic electromagnetic shielding provisions; – dimensions of the key/coding system for subrack and plug-in units; – dimensions of the alignment pin for front panel and plug-in unit; – dimensions of electrostatic discharge provisions; – dimensions of rear-mounted plug-in units. Connector-related dimensions are given in Annex A. In order to ensure the compatibility of plug-in units into the subrack, inspection dimensions and connector-dependent dimensions are defined. NOTE The drawings used in this part of IEC 60917 are not intended to indicate product design, only the specific dimensions that are used.

Modular order for the development of mechanical structures for electronic equipment practices - Part 2-3: Sectional specification - Interface co-ordination dimensions for the 25 mm equipment practice - Extended detail specification - Dimensions for subrac

ICS
31.240
CCS
发布
2015-09-03
实施

This part of IEC 62610 provides an evaluation method for thermoelectrical cooling systems (Peltier effect).With this design guide it is possible to calculate the efficiency of the thermoelectrical cooling system (Peltier effect) and its cooling power depending on the ambient temperature and internal temperature. This design guide can also be used to appraise thermoelectrical cooling systems by its efficiency.

Mechanical structures for electronic equipment - Thermal management for cabinets in accordance with IEC 60297 and IEC 60917 series - Part 3: Design guide: Evaluation method for thermoelectrical cooling systems (Peltier effect)

ICS
31.240
CCS
发布
2015-09-03
实施

This part of IEC 60297 covers the basic dimensional relationship of a modular range of subracks and associated plug-in units in compliance with the IEC 60297 series. The purpose of this standard is to specify dimensions which will ensure dimensional interchangeability of subracks and associated plug-in units. Connector related dimensions are limited to “inspection dimensions” only. For mechanical and climatic tests refer to IEC 61587-1. For electromagnetic shielding performance tests, refer to IEC 61587-3.

Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-101: Subracks and associated plug-in units

ICS
31.240
CCS
发布
2015-09-03
实施

This part of IEC 61587 specifies environmental requirements, test set-up, as well as safety aspects for empty enclosures, i.e. cabinets, racks, subracks and chassis under indoor conditions. The purpose of this standard is to establish defined levels of physical performance in order to meet certain requirements of storage, transport and final location conditions. It applies in whole or part only to the mechanical structures of cabinets, racks, subracks and chassis, but it does not apply to electronic equipment.

Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 series - Part 1: Environmental requirements, test set-up and safety aspects for cabinets, racks, subracks and chassis under indoor conditions

ICS
31.240
CCS
发布
2015-09-03
实施

This Technical Specification provides guidelines for the installation of thermoelectrical cooling systems (Peltier effect) within cabinets of the IEC 60297 (19 inch) and IEC 60917 (25 mm) series. The cooling performance is in direct relation with the mounting location within a cabinet. Three typical mounting locations are identified: – mounting location 1: cabinet with inside or outside mounted thermoelectrical cooling system for the cooling of a whole cabinet; – mounting location 2: cabinet with top mounted thermoelectrical cooling system for the cooling of a whole cabinet; – mounting location 3: cabinet with inbuilt thermoelectrical cooling system in form of a subrack for hot spot cooling.

Mechanical structures for electronic equipment - Thermal management for cabinets in accordance wit IEC 60297 and IEC 60917 series - Part 1: Design guide: Interface dimension and provision for thermoelectrical cooling systems (Peltier effect)

ICS
31.240
CCS
发布
2015-09-03
实施

This section of IEC 917-2 is a detail specification which is to be used in whole or in part in all fields of electronics where devices and systems are designed according to the sectional specification IEC 917-2. The dimensions in the tables of this detail specification are a selection from the sectional specification IEC 917-2. All other sizes from the sectional specification are valid in this detail specification provided the relationship between the dimensions is maintained, i.e. the dimensional difference between the co-ordination dimensions HC ,Wc and Dc and dimensions Hc0, Hc1 , Hc2 ; Wc0 , Wc1 and Dco, Dc1 shown in tables 1, 2 and 3 are to be maintained. The purpose of this publication is the specification of dimensions which will ensure mechanical interchangeability of cabinets and racks, and ensure mechanical interchangeability for subrack mounting. Cabinets and racks can be arranged together to form larger operating units. Application of specific cabinets or racks, attachments and accessories, such as heat exchangers, control elements, switches, etc. does not form part of this specification.

Modular order for the development of mechanical structures for electronic equipment practices - Part 2: Sectional specification - Interface co-ordination dimensions for the 25 mm equipment practice - Section 1: Detail specification - Dimensions for cabine

ICS
31.240
CCS
发布
2015-09-03
实施

This part of IEC 60297 covers only the additional interface dimensions for an alignment pin and a keying device used with subracks and plug-in units according to IEC 60297-3-101. This standard may also be used in conjunction with IEC 60297-3-102.

Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-103: Keying and alignment pin

ICS
31.240
CCS
发布
2015-09-03
实施

This International Standard provides a method of thermal performance evaluation for empty indoor enclosures according to IEC 60917 and IEC 60297, and, for outdoor enclosures according to IEC 61969. This standard contains criteria to determine the thermal absorption factors relating to – principles of enclosure design; – internal heat load; – sun radiation. The enclosure absorption factor is intended to provide a common value for comparing and selecting enclosures built in accordance with this standard.

Method of evaluating the thermal performance of enclosures

ICS
31.240
CCS
发布
2015-09-03
实施

This section of IEC 917-2 is a detail specification which is to be used in whole or in part in all fields of electronics where devices and systems are designed according to the sectional specification IEC 917-2. The purpose of this publication is the specification of dimensions which will ensure mechanical interchangeability of subracks, chassis, plug-in units, backplanes and front panels. The sectional specification IEC 917-2 has embodied within it a number of subrack systems based on 25 mm three-dimensional modularity and the binary additive principle for subrack heights. The dimensions in the tables of this detail specification are based on one of the subrack systems taken from the sectional specification IEC 917-2. However, all subrack systems within the sectional specification are valid in this detail specification, provided the relationship between the dimensions is maintained, i.e. the dimensional difference between the co-ordination dimensions HS, Ws and DS and dimensions HS0 , etc.; WS0 , etc., and Dso,etc., shown in tables 1, 2 and 3 are to be maintained. The subrack dimensions are related to certain cabinet/rack dimensions, see IEC 917-2-1. The front panel dimensions are related to the mounting dimensions of certain cabinets and racks, see IEC 917-2-1. Plug-in units are mounted in subracks. They serve as supports for electrical, electronic and mechanical components. The electrical connection between plug-in units and subracks is based on the use of connectors. All dimensions are given in millimetres and the drawings are first angle projections.

Modular order for the development of mechanical structures for electronic equipment practices - Part 2: Sectional specification - Interface co-ordination dimensions for the 25 mm equipment practice - Section 2: Detail specification - Dimensions for subrac

ICS
31.240
CCS
发布
2015-09-03
实施

This part of IEC 61969 specifies a set of basic environmental requirements and tests, as well as safety aspects for outdoor enclosures under conditions of non-weatherprotected locations above ground. The purpose of this standard is to define a minimum level of environmental performance in order to meet requirements of storage, transport and final installation. It is the intention to establish basic environmental performance criteria for outdoor enclosure compliance.

Mechanical structures for electronic equipment - Outdoor enclosures - Part 3: Environmental requirements, tests and safety aspects

ICS
31.240
CCS
发布
2015-09-03
实施

This part of IEC 61969 applies to the design of enclosures for outdoor applications for stationary use at non weatherprotected locations as defined in IEC 61969-1 Ed.2.0. The internal and external coordination dimensions are derived from IEC 60917-2. The internal dimensions meet the mounting dimensions of subracks in accordance with IEC 60917-2-2 and IEC 60297-3. The external dimensions, compared to IEC 60917-2, are partly increased in order to meet the design requirements of the outdoor specific conditions.

Mechanical structures for electronic equipment - Outdoor enclosures - Part 2: Coordination dimensions

ICS
31.240
CCS
发布
2015-09-03
实施

This part of IEC 60297 covers only the additional interface dimensions for injector/extractor devices used with subracks and plug-in units according to IEC 60297-3-101. This standard may also be used in conjunction with IEC 60297-3-103.

Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-102: Injector/extractor handle

ICS
31.240
CCS
发布
2015-09-03
实施