91.060.10 墙、隔墙、面墙 标准查询与下载



共找到 684 条与 墙、隔墙、面墙 相关的标准,共 46

本文件规定了采用振动测试法排查既有建筑幕墙面板坠落风险的原理、检测设备、检测步骤、结果判定和检测报告。 本文件适用于既有建筑幕墙面板因支承不牢固(如隐框玻璃幕墙硅酮结构胶的粘结失效,石材及金属幕墙挂件、栓件的脱挂、漏挂、螺栓松动等)造成的坠落风险部位的定位,既有建筑幕墙安全检测中幕墙面板坠落风险排查可参照使用。

Investigation method for falling risk of the existing building curtain wall panels-Vibration test method

ICS
91.060.10
CCS
E501
发布
2023-03-17
实施
2023-03-28

本规程共分9章和3个附录,主要内容包括:总则、术语和符号、材料、建筑设计、结构设计、加工制作、安装施工、工程验收、保养和维修等。

Technical specification for glazed composite panel curtain wall engineering

ICS
91.060.10
CCS
E4710
发布
2023-03-10
实施
2023-03-30

1.1 This specification covers molded glass fiber reinforced gypsum (GRG) parts, which are nonload-bearing, thin-shell, ornamental shapes for architectural embellishment of interior building construction. 1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.3 The information presented refers to the molded surface of the part. 1.4 The text of this standard references footnotes, which provide explanatory material. These footnotes shall not be considered as requirements of the standard. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Molded Glass Fiber Reinforced Gypsum Parts

ICS
91.060.10
CCS
发布
2023-03-01
实施

This specification covers woven wire plaster base, flat or self-furring, with or without stiffener wires, and with or without backing, designed for use as a base to receive gypsum or Portland cement based plaster. Backing shall allow lapping of wire-to-wire and backing-to-backing of one mesh at ends and edges and shall have a minimum tensile breaking strength. The wire shall be zinc-coated (galvanized). The weight, size, and diameter of the wire are specified.

Standard Specification for Woven Wire Plaster Base

ICS
91.060.10
CCS
发布
2023-02-28
实施

本标准共分9章和1个附录,主要内容包括:总则、术语、基本规定、性能要求、建筑设计、结构设计、构造设计、建筑幕墙设计阶段及要求、建筑幕墙信息化模型设计(BIM)等。

Building Curtain Wall Design Standards

ICS
91.060.10
CCS
E4710
发布
2023-02-06
实施
2023-03-17

1.1 This guide describes the types of project-specific construction conditions that need to be communicated by means of drawings (“details”) for the purpose of constructing Exterior Insulation and Finish System (EIFS)-clad barrier and drainage wall assemblies. EIFS manufacturers provide basic details for the installation of their materials and interface with adjacent materials. These details are generic and, in many cases, do not apply to specific project conditions. 1.2 This guide addresses only the EIFS itself and the interface between the EIFS and the materials immediately adjacent to the EIFS; it does not address all parts of the wall assembly. 1.3 Not all possible construction detail conditions are addressed by this guide. Identify and provide details for all construction conditions that exist on a specific building. 1.4 This guide is intended to supplement but not supersede information from the EIFS manufacturer about how their specific product should be detailed, nor to supersede technical product acceptance reports or the code requirements of regulatory authorities. 1.5 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Guide for Detailing of EIFS-Clad Barrier and Drainage Wall Assemblies

ICS
91.060.10
CCS
发布
2023-02-01
实施

1.1 This test method covers the determination of the resistance of exterior windows, curtain walls, skylights, and doors to water penetration when water is applied to the outdoor face and exposed edges simultaneously with a uniform static air pressure at the outdoor face higher than the pressure at the indoor face. 1.2 This test method is applicable to any curtain-wall area or to windows, skylights, or doors alone. 1.3 This test method addresses water penetration through a manufactured assembly. Water that penetrates the assembly, but does not result in a failure as defined herein, may have adverse effects on the performance of contained materials such as sealants and insulating or laminated glass. This test method does not address these issues. 1.4 The proper use of this test method requires a knowledge of the principles of pressure measurement. 1.5 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see 7.1. 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference

ICS
91.060.10
CCS
发布
2023-02-01
实施

1   Scope This document specifies the test method to evaluate the inter-storey displacement resistance of curtain walling to three-directional seismic or wind actions when curtain walling is subjected to repeated movement. The test method allows to determine, depending on the axes of the displacement imposed: — horizontal inter-storey displacement in-plane resistance ; — horizontal inter-storey out-plane displacement resistance ; — vertical inter-storey in-plane displacement resistance ; — combined inter-storey displacement resistance . The test method can be used to evaluate the inter-storey displacement either when it is a design requirement or to assess the relative displacement accommodated by the curtain walling assembly. This test can be addressed manually or automatically depending on the size and/or the shape of the specimen.

Curtain walling. Inter-storey displacement resistance. Test method

ICS
91.060.10
CCS
发布
2022-12-31
实施
2022-12-31

Code for design of prefabricated shear wall structures

ICS
91.060.10
CCS
P25
发布
2022-12-29
实施
2023-07-01

1.1 This specification covers dry-cast segmental retaining wall units of concrete, machine–made from hydraulic cement, water, and suitable mineral aggregates with or without the inclusion of other materials. The units are intended for use in the construction of mortarless segmental retaining walls. NOTE 1—When particular features are desired, such as density classification, higher compressive strength, surface texture, finish, color, or other special features, such properties should be specified separately by the purchaser. Suppliers should be consulted as to availability of units having the desired features. 1.2 The text of this standard references notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. 1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Dry-Cast Segmental Retaining Wall Units

ICS
91.060.10
CCS
发布
2022-12-15
实施

本文件规定了建筑外墙防水装饰工程验收的基本规定、施工过程验收和竣工验收的内容。 本文件适用于对建筑外墙防水装饰工程进行验收。

Acceptance rules for building exterior wall waterproof decoration project

ICS
91.060.10
CCS
E501
发布
2022-12-15
实施
2022-12-20

1 总则 2 术语 3 基本规定 4 材料 5 设计 6 施工 7 验收

Technical specification for application of sintered thermal insulation lightweight composite wallboard

ICS
91.060.10
CCS
E4710
发布
2022-12-12
实施
2023-02-21

本文件规定了室内装饰用石塑板材的术语和定义、分类和标记、基本要求、技术要求、试验方法、检验规则、标志、包装、运输及贮存和质量承诺。 本文件适用于石粉和PVC树脂组成的室内装饰用石塑板材(以下简称石塑板材)。

Stone-plastic sheet for interior decoration

ICS
91.060.10
CCS
C292
发布
2022-12-08
实施
2023-04-04

本规程规定了轻钢龙骨喷筑复合墙板的术语、材料、设计、施工、质量验收。

Technical regulations for the application of light steel keel spray-cast composite wall panels

ICS
91.060.10
CCS
E4710
发布
2022-12-02
实施
2022-12-02

前  言  1 范围  2 规范性引用文件  3 术语和定义  4 基本要求  5 材料  5.1 一般要求  5.2 混凝土、钢筋和钢材  5.3 套筒及连接材料  5.4 其他材料  5.5 材料管理  6 设计要求  6.1 一般要求  6.2 建筑平面设计  6.3 立面、外墙设计  6.4 预制构件设计  7 构建制作与运输  7.1 一般要求  7.2 工艺试验和检验  7.3 灌浆套筒剪力墙制作与验收  7.4 预制构件运输  8 预制构件安装  8.1 一般要求  8.2 安装与连接  9 验收  附录A(规范性)坐浆料性能指标  

Technical specification for grouting sleeve shear wall application

ICS
91.060.10
CCS
E4790
发布
2022-12-02
实施
2022-12-08

1.1 These test methods cover determination of the flexural bond strength of unreinforced masonry assemblages. Two procedures are provided: 1.1.1 Test Method A—Simply supported beam with thirdpoint loading. 1.1.2 Test Method B—Simply supported beam with uniform loading. NOTE 1—Third-point loading (Test Method A) produces a moment distribution that is significantly different from uniformly distributed loading (Test Method B).Third-point loading (Test Method A) subjects more mortar joints to the maximum moment and thus, is likely to produce more conservative capacities than uniform loading (Test Method B). 1.2 The text of this standard refers to notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. 1.3 These test methods cover the application of the tests using either inch-pound or SI units. The values stated in either SI units or inch-pound units are to be regarded separately as standard. Within the text, the inch-pound units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Test Methods for Flexural Bond Strength of Masonry

ICS
91.060.10
CCS
发布
2022-12-01
实施

1.1 This test method covers determination of the diagonal tensile or shear strength of masonry assemblages by loading them in compression along one diagonal (see Fig. 1), thus causing a diagonal tension failure with the specimen splitting apart parallel to the direction of load. 1.2 Annex A1 provides requirements regarding the determination of the diagonal-tension strength of masonry under combined diagonal-tension and compressive loading. 1.3 The text of this standard refers to notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. 1.4 These test methods cover the application of the tests using either inch-pound or SI units. The values stated in either SI units or inch-pound units are to be regarded separately as standard. Within the text, the inch-pound units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard. 1.5 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Test Method for Diagonal Tension (Shear) in Masonry Assemblages

ICS
91.060.10
CCS
发布
2022-12-01
实施

1.1 This test method describes an in situ method for determining the deformation properties of existing unreinforced solid-unit masonry. (See Note 1.) This test method concerns the measurement of in-situ masonry deformability properties in existing masonry by use of thin, bladder-like flatjack devices that are installed in cut mortar joints in the masonry wall. This test method provides a relatively nondestructive means of determining masonry properties. NOTE 1—Solid-unit masonry is that built with stone, concrete, or clay units whose net area is equal to or greater than 75 % of the gross area. 1.2 The text of this standard refers to notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. 1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Test Method for In Situ Measurement of Masonry Deformability Properties Using the Flatjack Method

ICS
91.060.10
CCS
发布
2022-12-01
实施

1.1 These test methods evaluate the flexural bond strength, normal to the bed joints, of masonry built of manufactured masonry units. Sampling and testing procedures are referenced, and terms are defined. Three different specimen fabrication methods are specified, each for a different purpose: 1.1.1 The first method is the “Test Method for LaboratoryPrepared Specimens.” Its purpose is to compare the bond strengths (under the given conditions) of masonry mortars. It could be used, for example, to check the quality of mortar products after production, or to indicate the bond strength (under the given conditions) of a mortar product without requiring the product to be tested in combination with many different units. It is not intended to represent field conditions. It uses standard concrete masonry units. Mortars are batched by weight equivalents of volume proportions and are mixed to a prescribed flow. Prisms are constructed using a jig and are bag-cured. 1.1.2 The second method is the “Test Method for FieldPrepared Specimens.” Its purpose is to evaluate the bond strength (under the given conditions) of a particular unit-mortar combination, either for preconstruction evaluation of materials or for quality control purposes during construction. Mortars are batched conventionally, and the flow is not prescribed. Prisms are constructed conventionally (no jig) and are bag-cured. 1.1.3 The third method is the “Test Method for Prisms Removed from Existing Masonry.” Its purpose is to evaluate the bond strength of unit-mortar combinations of prisms cut from existing walls. 1.1.4 The three methods are not consistent, nor are they intended to be. They are intended to be used for three different purposes. To make this clear, the three methods are presented separately. 1.1.5 Appendix X1 suggests two possible criteria for assessing the bond strength values obtained using these test methods. These possible evaluation criteria are given for illustration only and are not mandatory. 1.2 The text of this standard refers to notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. 1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Test Methods for Measurement of Masonry Flexural Bond Strength

ICS
91.060.10
CCS
发布
2022-12-01
实施

1 范围  2 规范性引用文件  3 术语和定义  4 基本要求  5 材料  6 基层工艺  7 施工 8 验收  附录 A(规范性)复试项目 

Specication for construction and acceptance of building finishings for interior and exterior wall

ICS
91.060.10
CCS
E501
发布
2022-11-25
实施
2022-11-30



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号