93.030 外部污水排放系统 标准查询与下载



共找到 509 条与 外部污水排放系统 相关的标准,共 34

Drain and sewer systems outside buildings - Management and control of activities - Part 3 : drain and sewer cleaning

ICS
93.030
CCS
发布
2021-01-20
实施
2021-03-10

This document establishes requirements for the management and control of activities in drain and sewer systems outside buildings and specifies requirements for development and implementation of work programmes, and the selection of techniques. This document together with EN 14654-1:2021 covers the control of inputs from users. It is applicable to drain and sewer systems from the point where wastewater leaves a building, roof drainage system, or paved area, to the point where it is discharged into a wastewater treatment plant or receiving water body. Drains and sewers below buildings are included provided that they do not form part of the drainage system of the building.

Drain and sewer systems outside buildings - Management and control of activities - Part 4: Control of inputs from users

ICS
93.030
CCS
发布
2021-01-20
实施
2021-04-30

Domaine d'applicationLe présent document établit les prescriptions de gestion et de contrôle des activités dans les réseaux d'évacuation et d'assainissement à l'extérieur des bâtiments, et spécifie les prescriptions concernant l'élaboration et la mise en oeuvre de programmes de t

Drain and sewer systems outside buildings - Management and control of activities - Part 1 : general requirements

ICS
93.030
CCS
发布
2021-01-20
实施
2021-03-10

Automobile roads of general use. Drainage system. Requirements for design

ICS
93.030
CCS
发布
2021-00-00
实施
2021-09-01

Design, material, and manufacturing requirements for prefabricated septic tanks and sewage holding tanks

ICS
93.030
CCS
发布
2021-00-00
实施

Rainstorm Intensity Formula and Design Rainstorm Pattern in Wuhan City

ICS
93.030
CCS
P41
发布
2020-12-14
实施
2021-01-14

本文件规定了复合平壁钢塑嵌入式无缝排水管的术语和定义、符号、材料、产品结构与分类、 技术要求、试验方法、检验规则、标志、运输、贮存。 本文件适用于输送介质温度在45 ℃以下的埋地市政排水、建筑室外排水、工业废水以及水利排水等工程的复合平壁钢塑嵌入式无缝排水管。

Composite flat wall steel plastic embedded seamless drain pipe

ICS
93.030
CCS
E485
发布
2020-12-09
实施
2020-12-11

Plastics piping systems for non-pressure underground drainage and sewerage--Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE)--Part 3: Specifications for pipes and fittings with smooth i

ICS
93.030
CCS
发布
2020-12-02
实施
2020-12-02

1.1 This specification describes material and physical requirements for nonrigid poly (vinyl chloride) (PVC) preformed molded and spliced gaskets used in mechanical couplings. These couplings are used in gravity flow drain, waste, and vent (DWV), sewer, sanitary, and storm plumbing systems. They include couplings to join similar and dissimilar piping sizes and piping material. 1.2 It is acceptable to use recycled materials in this product in accordance with the requirements in Section 4. 1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. NOTE 1—There is no known ISO equivalent to this standard. 1.4 The following safety hazards caveat pertains only to the test method portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Poly (Vinyl Chloride) (PVC) Gaskets for Drain, Waste, and Vent (DWV), Sewer, Sanitary, and Storm Plumbing Systems

ICS
93.030
CCS
发布
2020-12-01
实施

Plastics piping systems for non-pressure underground drainage and sewerage - Unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) - Part 2: Specifications for manholes and inspection chambers

ICS
93.030
CCS
发布
2020-11-02
实施
2020-11-02

Plastics piping systems for non-pressure underground drainage and sewerage - Unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) - Part 1: Specifications for ancillary fittings and shallow chambers

ICS
93.030
CCS
发布
2020-11-02
实施
2020-11-02

Standard Specification for 12 to 60 in. [300 to 1500 mm] Annular Corrugated Profile-Wall Polyethylene (PE) Pipe and Fittings for Gravity-Flow Storm Sewer and Subsurface Drainage Applications

ICS
93.030
CCS
发布
2020-11-01
实施

1.1 This specification covers the minimum performance and material requirements for resilient connectors used for connections between reinforced concrete manholes conforming to Specification C478/C478M and pipes, between wastewater structures and pipes, and between precast reinforced concrete pipe and laterals. 1.1.1 These connectors are designed to minimize leakage between the pipe and manhole, and between the pipe and lateral. 1.2 The values stated in inch pound or SI units are to be regarded separately as standard. The SI units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard. NOTE 1—This specification covers the design, material, and performance of the resilient connection only. Connections covered by this specification are adequate for hydrostatic pressures up to 13 psi (30 ft) [90 kPa (9.1 m)] without leakage when tested in accordance with Section 7. Infiltration or exfiltration quantities for an installed system are dependent upon many factors other than the connections between manhole structures and pipe, and allowable quantities must be covered by other specifications and suitable testing of the installed pipeline and system. 1.3 The following precautionary caveat pertains only to the test methods portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For a specific precaution statement, see 7.2.5. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Resilient Connectors Between Reinforced Concrete Manhole Structures, Pipes, and Laterals

ICS
93.030
CCS
发布
2020-09-01
实施

Technical regulations for underground pipeline detection

ICS
93.030
CCS
P 41
发布
2020-06-08
实施
2020-07-01

Standard Specification for 150 to 1500 mm [6 to 60 in.] Annular Corrugated Profile-Wall Polyethylene (PE) Pipe and Fittings for Sanitary Sewer Applications

ICS
93.030
CCS
发布
2020-06-01
实施

本标准规定了新型冠状病毒肺炎(以下简称“新冠肺炎”)疫情防控期间市政排水运行管理的总则、市政设施运行管理技术要求、人员防护、水质监测以及协调控制措施。本标准适用于新冠肺炎疫情防控期间武汉市行政区域内市政排水运行管理工作,其他与冠状病毒相似的包膜病菌传染病防控期间的市政排水运行管理工作可参照执行。

Technical Guidelines for Municipal Drainage Operation and Management for Novel Coronavirus Pneumonia Epidemic Prevention and Control

ICS
93.030
CCS
P41
发布
2020-05-15
实施
2020-06-15

1.1 This practice covers requirements and test methods for the reconstruction of a sewer service lateral pipe having an inner diameter of 3 to 12 in. (7.6 to 30.5 cm) and its connection to the main pipe having an inner diameter of 6 to 24 in. (15.2 to 61.0 cm) and up the lateral a maximum of 150 ft (46 m) without excavation. The lateral pipe is accessed remotely from the main pipe and from a lateral access point. This will be accomplished by the installation of a resin impregnated onepiece main and lateral cured-in-place lining (MLCIPL) by means of air inflation and inversion. The MLCIPL is pressed against the host pipe by pressurizing a bladder and is held in place until the thermoset resins have cured. When cured, the MLCIPL shall be a continuous, one piece, tight fitting, corrosion resistant lining extending over a predetermined length of the lateral pipe and the adjacent section of the main pipe, providing a verifiable non-leaking structural connection and seal. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 There is no similar or equivalent ISO Standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Practice for Rehabilitation of a Sewer Service Lateral and Its Connection to the Main Using a One Piece Main and Lateral Cured-in-Place Liner

ICS
93.030
CCS
发布
2020-03-01
实施

This document, together with ISO 21138-1, specifies the definitions and requirements for pipes with a non-smooth external surface and a smooth internal surface (Type B), fittings and systems based on unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) structured-wall piping systems intended to be used in non-pressure underground drainage and sewerage applications. NOTE 1 Pipes, fittings and the systems complying with this document can also be used for highway drainage and surface water. This document specifies test methods and test parameters. This document covers a range of pipe and fitting sizes, materials, pipe constructions and nominal ring stiffnesses, and gives recommendations concerning colours. NOTE 2 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and installation practices or codes. In conjunction with ISO 21138-1, this document is applicable to structured-wall pipes and fittings, to their joints and to joints with components of other plastics and non-plastics materials. It is applicable to pipes and fittings with or without an integral socket with elastomeric ring seal joints as well as welded and fused joints. NOTE 3 Pipes, fittings and other components conforming to any plastics product standards referred to in Clause 2 are deemed to be suitable for use with pipes and fittings conforming to this document, when they conform to the requirements for joint dimensions given in ISO 21138-2 or ISO 21138-3 (this document) and to the performance requirements given in Clause 10. NOTE 4 For dimensions larger than DN/OD 1200 or DN/ID 1200, this document can serve as general guidance regarding appearance, colour, physical and mechanical characteristics as well as performance requirements. Test methods are not included in this document.

Plastics piping systems for non-pressure underground drainage and sewerage — Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) — Pa

ICS
93.030
CCS
发布
2020-01-20
实施

This document, together with ISO 21138-1, specifies the definitions and requirements for pipes with smooth external and internal surfaces (Type A), fittings and systems based on unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) structured-wall piping systems intended to be used in non-pressure underground drainage and sewerage applications. NOTE 1 Pipes, fittings and the system complying with this document can also be used for highway drainage and surface water. This document specifies test methods and test parameters. This document covers a range of pipe and fitting sizes, materials, pipe constructions and nominal ring stiffnesses, and gives recommendations concerning colours. NOTE 2 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and installation practices or codes. In conjunction with ISO 21138-1, this document is applicable to structured-wall pipes and fittings, to their joints and to joints with components of other plastics and non-plastics materials. It is applicable to pipes and fittings with or without an integral socket with elastomeric ring seal joints as well as welded and fused joints. NOTE 3 For dimensions larger than DN/OD 1200, or DN/ID 1200, this document can serve as general guidance regarding appearance, colour, physical and mechanical characteristics as well as performance requirements. Test methods are not included in this document.

Plastics piping systems for non-pressure underground drainage and sewerage — Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) — Pa

ICS
93.030
CCS
发布
2020-01-20
实施

This document, together with ISO 21138-2 and ISO 21138-3, specifies the definitions and requirements for pipes, fittings and systems based on unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) structured-wall piping systems intended to be used in non-pressure underground drainage and sewerage applications. NOTE 1 Pipes, fittings and the system complying with this document can also be used for highway drainage and surface water. This document covers a range of pipe and fitting sizes, materials, pipe constructions, nominal ring stiffnesses, and gives recommendations concerning colours. NOTE 2 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and installation practices or codes. In conjunction with ISO 21138-2 and ISO 21138-3, this document is applicable to structured-wall pipes and fittings, to their joints and to joints with components of other plastics and non-plastics materials. It is applicable to structured-wall pipes and fittings with or without an integral socket with elastomeric ring seal joints as well as welded and fused joints. NOTE 3 Pipes, fittings and other components conforming to any plastics product standards referred to in the Bibliography can be used with pipes and fittings conforming to this document when they conform to the requirements for joint dimensions given in ISO 21138-2 and ISO 21138-3 and to the performance requirements given in Clause 9. NOTE 4 For dimensions larger than DN/OD 1200 or DN/ID 1200, this document can serve as a general guideline regarding appearance, colour, physical and mechanical characteristics as well as performance requirements.

Plastics piping systems for non-pressure underground drainage and sewerage — Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) — Pa

ICS
93.030
CCS
发布
2020-01-20
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved