本标准规定了罗茨真空泵型式与基本参数、技术要求、试验方法与检验规则、标志、包装、运输和贮存。 本标准适用于名义抽速为30L/s~20000L/s的单级双叶罗茨真空泵(以下简称泵)。

Roots vacuum pump

ICS
23.160
CCS
J78
发布
2005-05-18
实施
2005-11-01

These test methods are useful for routine control, design of end-use products, and acceptance testing for conformance to specifications. Good workmanship, seams, and joints that remain strong over a wide range of atmospheric conditions and have the ability to withstand repeated cycles are necessary for satisfactory end use to the consumer.1.1 These test methods cover the evaluation of the integrity of the primary disposable bag used for vacuum cleaners.1.2 The intent of these test methods is to verify that the design of the primary disposable bag will perform satisfactorily for the consumer in a wide range of normal use conditions. The filtering capability of the disposable bag is not evaluated with the use of these test methods.1.3 The following tests are included:Section Installation and Removal Workmanship Durability Seams and Joints1.4 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Methods for Evaluating Primary Disposable Bag Integrity for Vacuum Cleaners

ICS
97.080 (Cleaning appliances)
CCS
J78
发布
2005
实施

These test methods are useful for routine control, design of end-use products, and acceptance testing for conformance to specifications. Good workmanship, seams, and joints that remain strong over a wide range of atmospheric conditions and have the ability to withstand repeated cycles are necessary for satisfactory end use to the consumer.1.1 These test methods cover the evaluation of the integrity of the primary disposable bag used for vacuum cleaners. 1.2 The intent of these test methods is to verify that the design of the primary disposable bag will perform satisfactorily for the consumer in a wide range of normal use conditions. The filtering capability of the disposable bag is not evaluated with the use of these test methods. 1.3 The following tests are included: Section Installation and Removal3 Workmanship4 Durability5 Seams and Joints6 1.4 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. 1.5 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Methods for Evaluating Primary Disposable Bag Integrity for Vacuum Cleaners

ICS
97.080 (Cleaning appliances)
CCS
J78
发布
2005
实施

이 규격은 터보 분자 펌프의 성능 특성의 측정 방법에 대하여 규정한다. 모든 유형 및

Vacuum technology-Turbomolecular pumps-Measurement of performance characteristics

ICS
23.160
CCS
J78
发布
2004-12-30
实施
2004-12-30

이 규격은 진공 기술에서 사용되는 도시 기호에 대하여 규정한다.

Vacuum technology-Graphical symbols

ICS
23.160;01.080.30
CCS
J78
发布
2004-12-30
实施
2004-12-30

本标准规定了真空磁流体动密封件的型号编制、型式和尺寸、技术要求、标志、包装、贮存和运输。   本标准适用于外部压力为1×10^5Pa(大气压),真空室压力为1×10^-6Pa~1×10^5Pa(大气压)的真空设备的动密封。

Ferrofluid vacuum rotary feedthroughs

ICS
23.160
CCS
J78
发布
2004-10-20
实施
2005-04-01

本标准规定了真空阀门的型式与基本参数、技术要求、试验方法、检验规则、标志、包装、运输和贮存。 本标准适用于应用在真空系统中的电磁真空带充气阀、电磁高真空挡板阀、电磁高真空充气阀、高真空微调阀、高真空隔膜阀、高真空蝶阀、高真空挡板阀、高真空插板阀、真空调节阀、真空球阀、超高真空挡板阀、超高真空插板阀。

Vacuum valves

ICS
23.160
CCS
J78
发布
2004-10-20
实施
2005-04-01

本标准规定了抽速为30L/s~20000L/s的罗茨真空泵机组的型式与基本参数、技术要求、试验方法、检验规则以及标志、包装、运输、贮存。 本标准适用于以罗茨真空泵为主泵或中间泵,以滑阀真空泵、旋片真空泵、水环真空泵、油环真空泵、水环大气喷射泵、气冷式罗茨真空泵、往复真空泵为前级泵所组成的二级、三级或四级罗茨真空泵机组。

Roots vacuum pump system

ICS
23.160
CCS
J78
发布
2004-10-20
实施
2005-04-01

本标准规定了蒸汽流真空泵(包括扩散泵、扩散喷射泵)的型式、规格、基本参数、技术要求、试验方法、检验规则以及标志、包装、运输和贮存。 本标准适用于以油蒸气作为工作介质的扩散泵及扩散喷射泵。

Vapour vacuum pumps

ICS
23.160
CCS
J78
发布
2004-10-20
实施
2005-04-01

本标准规定了水蒸气喷射真空泵的型式与基本参数、技术要求、抽样及评定方法、试验方法、检验规则、标志、包装和运输。 本标准适用于获得10^(-3)kPa~10^(2)kPa压力的以水蒸气为工作介质的喷射真空泵。

Water vapour jet vacuum pump

ICS
23.160
CCS
J78
发布
2004-10-20
实施
2005-04-01

本标准规定了真空蒸发镀膜设备的型式和基本参数、技术要求、试验方法、检验规则及标增、包装、运输、贮存等要求。 本标准适用于极限压力在5×10^(-4)pa~5×10^(-3)Pa范围的真空蒸发镀膜设备。

Vacuum evaporation coating plant

ICS
23.160
CCS
J78
发布
2004-10-20
实施
2005-04-01

本标准规定了水喷射真空泵的型式与基本参数、技术要求及试验方法、检验规则、标志、包装和运输。   本标准适用于以水为工作介质、抽气量为32m^3/h~2000m^3/h的水喷射真空泵。被抽介质为空气或以不凝结性气体为主,凝结性气体为辅的气体。

Water ejector vacuum pump

ICS
23.160
CCS
J78
发布
2004-10-20
实施
2005-04-01

MIL-B-50015B remains inactive for new design, however, the document is valid for use.

BULB, ASPIRATOR

ICS
23.160
CCS
J78
发布
2004-07-28
实施

When applied in the case in which there is no test item in the vacuum chamber (such as during bake-out operations), this procedure may be used to evaluate the performance of the vacuum chamber in relation to other data from the same or other chambers given that critical parameters (for example, length of exposure, temperature of the chamber and cold finger, anisotropy, and so forth) can be related. The procedure can be used to evaluate the effects of materials found in the residue on items placed in the vacuum chamber. The procedure can be used to describe the effect of a prior test on the residual gases within a vacuum chamber. By selecting the time at which the coolant is introduced into the cold finger, the environment present during a selected portion of a test can be characterized. This can be used to determine the relative efficacy of certain vacuum chamber procedures such as bake-out. The procedure may be used to define the outgassed products of a test item that condense on the cold finger. The procedure may be used in defining the relative cleanliness of a vacuum chamber. In applying the results of the procedure to the vacuum chamber in general, consideration must be given to the anisotropy of the molecular fluxes within the chamber. The procedure is sensitive to both the partial pressures of the gases that form the condensibles and the time of exposure of the cold finger at coolant temperatures. The procedure is sensitive to any losses of sample that may occur during the various transfer operations and during that procedure wherein the solvent is evaporated by heating it on a steam bath. Note 18212;Reactions between solvent and condensate can occur and would affect the analysis.1.1 This practice covers a technique for collecting samples of materials that are part of the residual gas environment of an evacuated vacuum chamber. The practice uses a device designated as a "cold finger" that is placed within the environment to be sampled and is cooled so that constituents of the environment are retained on the cold-finger surface.1.2 The practice covers a method for obtaining a sample from the cold finger and determining the weight of the material removed from the cold finger.1.3 The practice contains recommendations as to ways in which the sample may be analyzed to identify the constituents that comprise the sample.1.4 By determining the species that constitute the sample, the practice may be used to assist in defining the source of the constituents and whether the sample is generally representative of samples similarly obtained from the vacuum chamber itself.1.5 This practice covers alternative approaches and usages to which the practice can be put.1.6 The degree of molecular flux anisotropy significantly affects the assurance with which one can attribute characteristics determined by this procedure to the vacuum chamber environment in general.1.7 The temperature of the cold finger significantly affects the quantity and species of materials collected.This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see Section .

Standard Practice for Determining Vacuum Chamber Gaseous Environment Using a Cold Finger

ICS
23.160 (Vacuum technology)
CCS
J78
发布
2004
实施

本标准规定了涡轮分子泵性能参数的测量方法,它适用于所有规格和所有型式的涡轮分子泵。 包括: a) 带机械或磁轴承的; b) 带或不带附加牵引级的。 注:由于涡轮分子泵需要前级泵支持,下列曲线将作为对体积流率—人口压力的曲线补充,以完全确定其性能: 一流量曲线; 一——压缩比曲线; 人口压力变化曲线。 包括全部有关区域和各种气体。

Vacuum technology - Turbomolecular pumps - Measurement of performance characteristics

ICS
23.160
CCS
J78
发布
2003-07
实施

The document purpose of this Standard is to ensure that the evaluation of the features of a Ion Getter pump is to be done under uniform proceedings and conditions. It should be achieved, that the measures done by different manufacturers and labs and the information given in catalogues are in principle comparable.#,,#

Vacuum technology - Acceptance specifications for getter ion pumps

ICS
23.160
CCS
J78
发布
2003-04
实施

이 규격은 질량 분광계형 누설 탐지기의 교정에 사용되는 절차를 규정한다. 이 규격

Vacuum technology-Mass-spectrometer-type leak-detector calibration

ICS
23.16
CCS
J78
发布
2002-12-31
实施
2002-12-31

이 규격은 액화 석유 가스 또는 도시 가스(1)(이하, 가스라 한다.)를 연료로 하는 표시

Method of testing for annual efficiency of gas hot water boiler

ICS
27.060.30
CCS
J78
发布
2002-12-27
实施
2002-12-27

Vacuum technology; rules for the measurement of steam jet vacuum pumps and steam jet compressors using steam as the working fluid

ICS
23.160
CCS
J78
发布
2002-06
实施

JB/T 6924—1998《干燥设备 产品型号编制方法》进行编制的。 本标准规定了箱式热风木材干燥机的结构型式、基本参数、技术要求、试验方法、检验规则及包装、运输、储存等要求。 本标准适用于生物质(木材边角料等)为主要燃料的箱式热风木材干燥机,液化石油气、煤炭、燃料油为燃料的箱式热风木材干燥亦可参照执行。 本标准于2001年6月首次发布。

Box type wood dryer with hot-air

ICS
CCS
J78
发布
2001-06-04
实施
2001-10-01