L23 连接器 标准查询与下载



共找到 3934 条与 连接器 相关的标准,共 263

Estimation of the reliability of electrical connectors

ICS
29.120.30;31.220.10
CCS
L23
发布
2017-02-28
实施
2017-02-28

Connectors for electronic equipment. Detail specification for 8-way, unshielded, free and fixed high density connectors for data transmission with frequencies up to 250 MHz and with current carrying capacity up to 1 A

ICS
31.220.10
CCS
L23
发布
2017-02-28
实施
2017-02-28

This part of IEC 61076 describes M12 circular connectors with two data pairs and power contacts with current ratings up to 12 A, that are typically used for data and power applications in industrial premises. These connectors consist of both fixed and free connectors either rewireable or non rewireable, with screw-locking. Male connectors have round contacts diameters of 1,50 mm, 1,00 mm and 0,60 mm. The different codings provided by this document prevent the mating of accordingly coded male or female connectors to any other similarly sized interfaces covered by other standards and the cross-mating between the different codings provided by this document. NOTE M12 is the dimension of the thread of the screw locking mechanism of these circular connectors.

Connectors for electronic equipment - Product requirements - Part 2-113: Circular connectors - Detail specification for connectors with M12 screw locking with power and signal contacts for data transmission with frequency up to 100 MHz

ICS
31.220.10
CCS
L23
发布
2017-02
实施
2017-02-23

Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-37: Tests - Cable bending for fibre optic closures (IEC 61300-2-37:2016); German version EN 61300-2-37:2016

ICS
33.180.20
CCS
L23
发布
2017-02
实施

Flanges for waveguides - Part 1: General requirements (IEC 60154-1:2016); German version EN 60154-1:2016

ICS
33.120.10
CCS
L23
发布
2017-02
实施

Fibre optic interconnecting devices and passive components. Performance standard. Single-mode fibre non-connectorized fixed attenuator. Category U in uncontrolled environment

ICS
33.180.20
CCS
L23
发布
2017-01-31
实施
2017-01-31

This part of 60309 applies to a single type of plug, socket-outlet, ship connector and ship inlet, hereinafter referred to as accessories, intended to connect ships to dedicated shore supply systems described in IEC/IEEE 80005-3. This part of IEC 60309 applies to three-phase accessories with an earth contact and with four pilot contacts. NOTE 1 In the following countries the term "ground" is used instead of "earth": US. These accessories have a maximum rated current of 350 A and a maximum rated operating voltage not exceeding 690 V 50/60 Hz. NOTE 2 The various operating currents, voltages and frequencies required for various types of ship are set by the shore supply system described in IEC/IEEE 80005-3. These accessories are intended to be installed and operated by instructed persons (IEC 60050-195:1998, Amendment 1:2001, 195-04-02) or skilled persons (IEC 60050-195:1998, Amendment 1:2001, 195-04-01) only. This standard applies to accessories for primary use outdoors in a seawater environment when the ambient temperature is normally within the range of -25 °C to +40 °C. NOTE 3 In some countries, other ambient temperatures may prevail and may need to be taken into account. These accessories are intended to be connected to cables of copper or copper alloy only. Socket-outlets or ship inlets incorporated in or fixed to electrical equipment which is part of the shore connection system are within the scope of this standard. In locations where special conditions prevail, for example where explosions are liable to occur, additional requirements may be necessary.

Plugs, socket-outlets and couplers for industrial purposes - Part 5: Dimensional compatibility and interchangeability requirements for plugs, socket-outlets, ship connectors and ship inlets for low-voltage shore connection systems (LVSC)

ICS
29.120.30;47.020.60
CCS
L23
发布
2017-01
实施
2017-01-26

This part of IEC 62946 covers 8-way, unshielded free and fixed high density connectors for data transmission with frequencies up to 250 MHz and with extra low voltage current carrying capabilities up to 1 A, and is intended to specify the common dimensions, mechanical, electrical, signal integrity and environmental characteristics and tests for these connectors.

Connectors for electronic equipment - Part 02: Detail specification for 8-way, unshielded, free and fixed high density connectors for data transmission with frequencies up to 250 MHz and with current carrying capacity up to 1 A

ICS
31.220.10
CCS
L23
发布
2017-01
实施
2017-01-24

1.1 This specification establishes the requirements for copper alloy strip for use in the manufacture of electrical connectors or spring contacts produced from one of the following Copper Alloy UNS Nos.2: C14530, C15100, C15500, C17000, C17200, C17410, C17450, C17460, C17500, C17510, C19002, C19010, C19015, C19025, C19210, C19400, C19500, C19700, C23000, C26000, C40810, C40850, C40860, C42200, C42500, C42520, C42600, C50580, C50780, C51000, C51080, C51100, C51180, C51980, C52100, C52180, C52480, C63800, C64725, C65400, C68800, C70250, C70260, C70265, C70310, C70350, C75200, and C76200. 1.2 The requirements for the other copper alloys such as copper-nickel-tin spinodal, UNS C72650, C72700, and C72900, shall be as prescribed in the current edition of Specification B740. 1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Copper Alloy Strip for Use in Manufacture of Electrical Connectors or Spring Contacts

ICS
29.050
CCS
L23
发布
2017
实施

Radio-frequency connectors. Sectional specification for coaxial connectors with 10 mm inner diameter of outer conductor, nominal characteristic impedance 50 $2I, series 4,3-10

ICS
33.120.30
CCS
L23
发布
2016-12-31
实施
2016-12-31

Connectors for electronic equipment. Product requirements. Detail specification for free and fixed connectors for data transmission with frequencies up to 3 000 MHz

ICS
31.220.10
CCS
L23
发布
2016-12-31
实施
2016-12-31

Radio-frequency connectors. Sectional specification for RF coaxial connectors with blind-mate coupling. Characteristic impedance 50 (type SBMA)

ICS
33.120.30
CCS
L23
发布
2016-12-31
实施
2016-12-31

Connectors for electronic equipment -- Tests and measurements -- Part 22-1: Capacitance tests -- Test 22a: Capacitance

ICS
31.220.01
CCS
L23
发布
2016-12-20
实施

Connectors for electronic equipment -- Tests and measurements -- Part 8-2: Static load tests (fixed connectors) -- Test 8b: Static load, axial

ICS
31.220.01
CCS
L23
发布
2016-12-20
实施

Connectors for electronic equipment -- Tests and measurements -- Part 12-1: Soldering tests -- Test 12a: Solderability, wetting, solder bath method

ICS
31.220.10
CCS
L23
发布
2016-12-20
实施

Connectors for electronic equipment -- Tests and measurements -- Part 12-5: Soldering tests -- Test 12e: Resistance to soldering heat, soldering iron method

ICS
31.220.10
CCS
L23
发布
2016-12-20
实施

Connectors for electronic equipment -- Tests and measurements -- Part 12-4: Soldering tests -- Test 12d: Resistance to soldering heat, solder bath method

ICS
31.220.10
CCS
L23
发布
2016-12-20
实施

Connectors for electronic equipment -- Tests and measurements -- Part 12-2: Soldering tests -- Test 12b: Solderability, wetting, soldering iron method

ICS
31.220.10
CCS
L23
发布
2016-12-20
实施

This clause of Part 1 is applicable except as follows: Replacement: Replace the first paragraph with the following: This part of IEC 62735, which is a technical specification, applies to plugs and fixed socket- outlets for class I equipment with two active contacts plus an earthing contact, a rated power of 5,2 kW and a rated voltage range from 294 V to 400 V d.c. They are intended to power d.c. information and communication technology equipment only. The 2,6 kW system complying with Part 1 is safely compatible with the system complying with this part as it is possible to insert the 2,6 kW plug in the 5,2 kW socket-outlet but it is not possible to insert the 5,2 kW plug into the 2,6 kW socket-outlet. Replace the third paragraph with the following: The maximum current for the plug and the socket-outlet is 13 A when the voltage between live contacts is 400 V d.c; 17,6 A when the voltage between live contacts is 294 V d.c. and can rise up to 20 A when the voltage between live contacts decreases to 260 V d.c. for 10 min maximum. Replace, in the 6th paragraph, the second dash with; an overcurrent protection (of 17,6 A or less for each socket-outlet or multiple socket- outlet).

Direct current (DC) plugs and socket-outlets for information and communication technology (ICT) equipment installed in data centres and telecom central offices - Part 2: Plug and socket-outlet system

ICS
29.120.30
CCS
L23
发布
2016-12-14
实施

Connectors for electronic equipment - Part 7-81: Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 2000 MHz (IEC 60603-7-81:2015); German version EN 60603-7-81:2016

ICS
31.220.10
CCS
L23
发布
2016-10
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved