Describes the well positions required of a microplate that is considered to meet the standards. This standard also outlines the conditions required for making necessary measurements.

Microplates - Well Positions

ICS
07.100
CCS
N61
发布
2004-01-08
实施

Describes the bottom outside flange dimensions required of a microplate that is considered to meet the standards. This standard also outlines the conditions required for making necessary measurements.

Microplates - Bottom Outside Flange Dimensions

ICS
07.100
CCS
N61
发布
2004-01-08
实施

These guidelines are intended to enable a laboratory monitor to perform onsite assessments of laboratory facilities. Accepted facilities will then participate in an interlaboratory test protocol to establish precision and bias for a particular ASTM standard. This assessment is intended to determine that all of the participants have the necessary equipment, an understanding of the test method, and the minimum level of skill necessary to gather data which are to be used to establish precision and bias for the particular standard. This guide is not intended to be used as a tool to qualify or accredit laboratories to perform any tests. Refer to the Referenced Documents for further guidance on accreditation requirements.1.1 This guide provides a general outline, for use by a laboratory monitor, to assess the qualifications of a laboratory which has requested to participate in a specific ASTM interlaboratory test.1.2 The preliminary assessment is based on observations made before initiation of any interlaboratory tests.1.3 The subcommittee, which appoints the laboratory monitor, specifies the minimum requirements which an organization should meet to qualify as a participant for the interlaboratory test. If a pretest is to be included, see details in Section .1.4 This fire standard can not be used to provide quantitative measures. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.

Standard Guide for Laboratory Monitors

ICS
71.040.10 (Chemical laboratories. Laboratory equip
CCS
N61
发布
2004
实施

To revise 3.11to indicate that modern technologies have been shown to be at least equivalent to the 1950s technology in regards to HEPA filters.

Class II (laminar flow) Biosafety Cabinetry

ICS
CCS
N61
发布
2004
实施

이 규격은 다음의 작업에 사용하는 엔클로저나 엔클로저 라인에 적용된다.

Containment enclosures-Part 1:Design principles

ICS
13.280
CCS
N61
发布
2003-12-06
实施
2003-12-06

Fume cupboards - Part 2 : safety and performance requirements.

ICS
71.040.10
CCS
N61
发布
2003-10-01
实施
2003-10-20

This part of ISO 14698 gives guidance on methods for the evaluation of microbiological data and the estimation of results obtained from sampling for viable particles in risk zones for biocontamination control. It should be used, where appropriate, in conjunction with ISO 14698-1.

Cleanrooms and associated controlled environments - Biocontamination control - Part 2: Evaluation and interpretation of biocontamination data

ICS
13.040.35
CCS
N61
发布
2003-09
实施

Part 1 of this European Standard gives terms and definitions for fume cupboards. The terms are related to types, components, design and construction, air flow and testing of fume cupboards. The annex A gives the translation of these terms into English, French, Italian, Spanish, Swedish, Danish and Netherlands.

Fume cupboards - Part 1: Vocabulary; German version EN 14175-1:2003

ICS
01.040.71;71.040.10
CCS
N61
发布
2003-08
实施

Part 2 of this European Standard specifies dimensions, safety and performance requirements for general purpose fume cupboards. It is not applicable to fume cupboards for carrying out work on radioactive materials or on microbiological agents, for which EN 12469 applies.

Fume cupboards - Part 2: Safety and performance requirements; German version EN 14175-2:2003

ICS
71.040.10
CCS
N61
发布
2003-08
实施
2003-08-01

The European Standard gives guidance for the installation of laboratory benches, storage units and services and their connections and fittings.#,,#

Laboratory furniture - Recommendations for design and installation; German version EN 14056:2003

ICS
71.040.10
CCS
N61
发布
2003-07
实施

1.1 Scope Replacement: This Part 2 is applicable to electrically powered LABORATORY CENTRIFUGES 1 1 1 Aspects excluded幻m the scope Addition: 一additional precautions which may need to be observed when centrifuging materials which are flammable or explosive(see 5 4 4 1 01): 一additional precautions which may need to be observed when centrifuging materials that chemically react vigorously(see 5.4 4 101) 1.1.1DM D2Modification off.1.1 ofthepart2to addthefollowing afterthelast dash —additional precautions related to safety hazards arising frOm leaking BIOSEALS and other biosafety components. 1 1 2 Equipment excludedfrom scope Addition: rotating electrical machinery within the scope of IEC 34 CENTRIFUGES(used in explosive atmospheres) 1.1.2DV D2 Modification off.1.2 ofthepart2to addthefollowing afterthelastdash —CENTRIFUGES(used with materials that are toxic,radioactive,or contaminated with pathogenic micro-organisms). 一BIOSEALS and other biosafety components CopyrighL by the Under.tiLers LaboraLories IⅡc Sun Sep 05 17:4~:46 2004

UL Standard for Safety Electrical Equipment for Laboratory Use; Part 2: Particular Requirements for Laboratory Centrifuges First Edition

ICS
71.040.20
CCS
N61
发布
2002-09-16
实施

1.1 Scope Replacement: This standard applies to AUTOCLAVES and STERILIZERS,including those with an automatic loading and unloading system,which incorporates a CHAMBER using toxic gas intended for the treatment of medical materials,and for laboratory processes,for example for sterilization NOTES 1 National and other regulations or codes apply for the safety of automatic loading and MRloading systems 2 In general it is considered that automatic control of the sterilization cycle is essential for the safe operation of equipment using toxic gases because a manual control system might present serious hazards(see 1 2)to the 0PERATOR 3 The principal sterilant gases in use are ethylene oxide and formaldehyde 4 For some applications,the CHAMBER may be operated at a pressure above or below atmospheric pressure. 5 All pressures are specified in absolute terms Atmospheric pressure(1 bar)≥100 kPa 6 The word AUTOCLAVES includes STERILIZERS unless specifically stated otherwise. Where an AUTOCLAVE incorporates a steam generator having its own PRESSURE VESSEL within the same enclosure for the purpose of humidifying the LOAD,the applicable safety requi rements specified in this standard apply also to the steam generator 1 1 2 Equipment excludedfromthe scope Addthefollowingtextatthe end ofthelastdash except for an atmosphere created by the AUTOCLAVE itself(see 13 2 103 1) Addition: Add the following new dash and notes Copyright by the UndenrriLers LaboraLories]nc

UL Standard for Safety Electrical Equipment for Laboratory Use; Part 2: Particular Requirements for Autoclaves and Sterilizers Using Toxic Gas for the Treatment of Medical Materials and for Laboratory Processes First Edition

ICS
11.080.10
CCS
N61
发布
2002-08-29
实施

1.1 These requirements apply to laboratory hoods and cabinets intended to provide an enclosed countertop work area with exhaust for containment and removal of vapors, mists, gases, and particulate matter from the work area. 1.2 These requirements do not cover ductless hoods (i.e., hoods that recirculate air back to room environment after filtering) or glove boxes. 1.3 These products are investigated for fire, electrical and mechanical risk of injuries only. A limited number of tests are conducted for minimal air flow capability. It remains for the user to determine that the hood performance, as confirmed by the requirements in this standard, meets the needs of the user. These needs depend on several factors, including installation with proper exhaust equipment, location within the room, the type of material being handled and the method in which the material is being handled. Also, suitability for use with perchloric acid or radiological materials is not investigated. 1.4 Requirements for the installation of laboratory hoods are included in the Standard for Fire Protection for Laboratories Using Chemicals, NFPA 45 and in the Method of Testing Performance of Laboratory Fume Hoods, ASHRAE 110. 1.5 Requirements for the installation of piped gas systems are contained in the following standards :a) National Fuel Gas Code, NFPA 54,b) Liquefied Petroleum Gas Code, NFPA 58,c) Gaseous Hydrogen Systems at Consumer Sites, NFPA 50A,d) Design and Installation of Oxygen-Fuel Gas Systems for Welding, Cutting, and Allied Processes, NFPA 51.

UL Standard for Safety Laboratory Hoods and Cabinets First Edition; Reprint with Revisions Through and Including June 2, 2006 [Superseded: UL SUBJECT 1805]

ICS
71.040.10
CCS
N61
发布
2002-06-07
实施

1.1 Scope This International Standard specifies general safety professional,industrial process,and educational use measu rement and test requirements for electrical equipment intended for including equipment and computing devices for: control, laboratory use; accessories intended for use with the above(e g sample handling equipment This Part 1 of the standard applies to the equipment defined in a)to c)below,when used under the environmental conditions of 1 4 a)Electrical measurement and test equipment This is equipment which by electrical means measu res,indicates or records one or more electrical or non-electrical quantities,also non-measu ring equipment such as signal generators measu rement standards,power supplies,transducers,transmitters,etc NOTE—All indicating and recording electrical measuring instruments(except those excluded in 1.1.2) fall within the scope of this standard unless they are panel meters designed only for building-in to other equipment.Built-in panel meters are considered as components and only need to meet the relevant requirements of IEC 1010,or other standards,as part of the equipment into which they are built b)Electrical control equipment This is equipment which controls one or more output quantities to specific values,with each value determined by manual setting,by local or remote programming,or by one or more input variables c)Electrical laboratory equipment This is equipment which measures,indicates,monitors or analyses substances,or is used to prepare materials This equipment may also be used in areas other than laboratories 1.1DV.1 DE Modification Delete”industrial process”and delete the first and second dashes frOm the first paragraph fUL 61010B-1 and UL 61010C-1 apply). Copyright.by the Underw~iLers LaboraLories]nc Sun Sep 05 13:05:17 g004

UL Standard for Safety Electrical Equipment for Laboratory Use; Part 1: General Requirements First Edition; Reprint with Revisions Thru and Including 12/6/2002 [Superseded: UL 1262, UL 1262] [Replaced: UL 3101-1]

ICS
71.040.20
CCS
N61
发布
2002-01-30
实施

Mechanical compactors are commonly used to replace the hand compactors required for Test Methods D 698 and D 1557 in cases where it is necessary to increase production. The design of mechanical compactors is such that it is necessary to have a calibration process that goes beyond determining the mass and drop of the hammer. Note 18212;The quality of the result produced by this standard is dependent on the competence of the personnel performing it, and the suitability of the equipment and facilities used. Agencies that meet the criteria is Practice D 3740 are generally considered capable of competent and objective testing/sampling/inspection/and the like. Users of this standard are cautioned that compliance with Practice D 3740 does not in itself assure reliable results. Reliable results depend on many factors; Practice D 3740 provides a means of evaluating some of those factors.1.1 These test methods for the calibration of mechanical soil compactors are for use in checking and adjusting mechanical devices used in laboratory compacting of soil and soil-aggregate in accordance with Test Methods D 698, D 1557 and other methods of a similar nature which might specify this method. Calibration for use with one method does not qualify the equipment for use with another method.1.2 The weight of the mechanical rammer is adjusted as described in and in order to provide that the mechanical compactor will produce the same result as the manual compactor.1.3 Two alternative procedures are provided as follows:SectionTest Method ACalibration based on the compaction of a selected soil sample5Test Method BCalibration based on the deformation of a standard lead cylinder61.4 If a mechanical compactor is calibrated in accordance with the requirements of either Test Method A or Test Method B, it is not necessary for it to meet the requirements of the other method.1.5 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Methods for Calibration of Laboratory Mechanical-Rammer Soil Compactors

ICS
13.080.99 (Other standards related to soil quality
CCS
N61
发布
2002
实施

1.1 These test methods for the calibration of mechanical soil compactors are for use in checking and adjusting mechanical devices used in laboratory compacting of soil and soil-aggregate in accordance with Test Methods D 698, D 1557 and other methods of a similar nature which might specify this method. Calibration for use with one method does not qualify the equipment for use with another method.1.2 The weight of the mechanical rammer is adjusted as described in and in order to provide that the mechanical compactor will produce the same result as the manual compactor.1.3 Two alternative procedures are provided as follows:SectionTest Method ACalibration based on the compaction of a selected soil sample5Test Method BCalibration based on the deformation of a standard lead cylinder61.4 If a mechanical compactor is calibrated in accordance with the requirements of either Test Method A or Test Method B, it is not necessary for it to meet the requirements of the other method.1.5 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Methods for Calibration of Laboratory Mechanical-Rammer Soil Compactors

ICS
13.080.99 (Other standards related to soil quality
CCS
N61
发布
2002
实施

1.1 This practice covers a method of preparing, maintaining, and using a temperature reference bath of a mixture of shaved ice and water, saturated with air at a pressure of 101 325 Pa (1 atm). 1.2 An industrial practice for relating values referenced to the ice point and to the water triple point on the ITS-90 is included. 1.3 Methods to promote uniformity of bath temperature by mechanical stirring or agitation are not described in detail. 1.4 Methods of approximating the ice point, as by thermostatically-controlled refrigeration, are not covered by this practice. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Practice for Preparation and Use of an Ice-Point Bath as a Reference Temperature

ICS
71.040.20 (Laboratory ware and related apparatus)
CCS
N61
发布
2002
实施

1.1 This practice covers a method of preparing, maintaining, and using a temperature reference bath of a mixture of shaved ice and water, saturated with air at a pressure of 101 325 Pa (1 atm). 1.2 An industrial practice for relating values referenced to the ice point and to the water triple point on the ITS-90 is included. 1.3 Methods to promote uniformity of bath temperature by mechanical stirring or agitation are not described in detail. 1.4 Methods of approximating the ice point, as by thermostatically-controlled refrigeration, are not covered by this practice. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Practice for Preparation and Use of an Ice-Point Bath as a Reference Temperature

ICS
71.040.20 (Laboratory ware and related apparatus)
CCS
N61
发布
2002
实施

Ballot of revisions of normative references, inflow velocity test apparatus, and Annexes A and F test requirements

Class II (Laminar Flow) Biohazard Cabinetry

ICS
CCS
N61
发布
2002
实施

Workbenches for laboratories - Dimensions, safety requirements and test methods.

ICS
71.040.10
CCS
N61
发布
2001-10-01
实施
2001-10-05



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号