K47 输电线路器材 标准查询与下载



共找到 464 条与 输电线路器材 相关的标准,共 31

Matting of insulating material for electrical purposes

ICS
29.020
CCS
K47
发布
2004-03-09
实施
2004-06-01

Live working - Care, maintenance and in-service testing of aerial devices with insulating booms

ICS
29.020
CCS
K47
发布
2004-03-09
实施
2004-06-01

Test guide of the insulating tool for live working

ICS
29.020
CCS
K47
发布
2004-03-09
实施
2004-06-01

Overhead conductor fittings of rated voltages up to 10kV

ICS
27.100
CCS
K47
发布
2004-03-09
实施
2004-06-01

本标准规定了颌定电压 lokv及以下架空绝缘导线金具型式、 分类及金具的技术条件。 本标准适用于颌定电压 l0kV及以下架空绝缘导线金具。

Overhead insulated conductor fittings of rated voltages up to 10kV

ICS
27.100
CCS
K47
发布
2004-03-09
实施
2004-06-01

本标准规定了带电作业用便携式接地和接地短路装置的设计、 制造、 选择、 使用与保养。 本标准适用于己停电的交流输变电与配电系绕以及电气设备) 220kV~500kv 输电线路绝缘架空地 线上及在试验室和试验设备上临时装设短路接地用的便携式接地和接地短路装置” 本标准不适用于在直流高压输电设备上所用的便携式接地和接地短路装置…

Portable equipment for earthing or earthing and short-circuiting for live working

ICS
29.020
CCS
K47
发布
2004-03-09
实施
2004-06-01

Guide of insulation co-ordination for live working

ICS
29.240.01
CCS
K47
发布
2004-03-09
实施
2004-06-01

本标准规定了带电作业工具、装置和设备的制造、选择、使用和维修的一般要求。 本标准适用于工具制造企业、有资格且能熟练地从事带电作业工作的工作人员安全地使用工具、 装置和设备。内容包括: a) 工器具特性; b) 使用條件; c) 维修条件。 本标准还包括制造厂提出的使用说明书,但不包括具体的带电作业方法。

Minimum requirements for the utilization of tools, devices and equipment for live working

ICS
29.020
CCS
K47
发布
2004-03-09
实施
2004-06-01

Live Working-Installation of distribution live conductors-stringing equipment and accessory items

ICS
29.020
CCS
K47
发布
2004-03-09
实施
2004-06-01

Flexible conductor cover (line hoses) of insulating material for live working

ICS
29.020
CCS
K47
发布
2004-03-09
实施
2004-06-01

Live working - Ladders of insulating material.

ICS
13.260;97.145
CCS
K47
发布
2004-02-01
实施
2004-02-05

MS39347A remains inactive for new design, however, the document is valid for use.

TERMINAL, POST, SERVICE AND GROUND

ICS
CCS
K47
发布
2004-01-20
实施

Applies to insulated and insulating hand tools used for working live or close to live parts at nominal voltages up to 1000 V a.c. and 1500 V d.c.

Live working - Hand tools for use up to 1000 V a.c. and 1500 V d.c.

ICS
13.260
CCS
K47
发布
2004-01
实施
2004-01-14

Applies to power apparatus bushings that have basic impulse insulation levels of 110 kV and above for use as components of oil-filled transformers and oil-filled reactors. Defines the special terms used, service conditions, rating, general requirements, and test procedure for apparatus bushings.

General requirements and test procedure for power apparatus bushings

ICS
CCS
K47
发布
2004
实施

Corrects editorial and technical errors that have been identified.

Standard Requirements for Overhead Pad-Mounted, Dry Vault, and Submersible Automatic Circuit Reclosers and Fault Interrupters for Alternating Current Systems Up to 38 kV - Corrigendum 1

ICS
29.120.50
CCS
K47
发布
2004
实施

Covers metal pipe, tubing, and structural brackets for wood poles designed to support luminaires of generally speherical, ellipsoidal, or rectangular shapes used in roadway and area lighting.

Roadway Lighting - Metal Brackets for Wood Poles

ICS
93.080.40
CCS
K47
发布
2004
实施

This International Standard covers telescopic sticks and telescopic measuring sticks to be used for live working on a.c. or d.c. electrical installations at 1 000 V and above for a.c. and 1 500 V and above for d.c. The telescopic sticks are designed to accept attachments that meet appropriate live working standards and, together with these attachments, may be used to perform mechanical work on live parts at a distance. Telescopic sticks are also designed to accept diagnostic devices that meet appropriate live working standards and are used to make the diagnostic devices reach parts of an installation to be tested. Telescopic measuring sticks, or tele-scopic sticks equipped with graduations, are used to measure distances to or between live parts. NOTE Under certain circumstances, the telescopic sticks covered by this standard can be used for installing portable earthing or earthing and short-circuiting equipment if the mechanical stresses during use are lower than the rated values. The tools (telescopic sticks and telescopic measuring sticks) covered by this standard are for use under dry conditions but could also be used under very humid conditions, using appropriate working procedures. Telescopic hook sticks are not covered by this standard. Telescopic bonding sticks and any other speciality telescopic sticks designed at the request of users are not covered by this standard.

Live working. Telescopic sticks and telescopic measuring sticks

ICS
13.260
CCS
K47
发布
2003-11-27
实施
2003-11-27

This part of IEC 61238 applies to compression and mechanical connectors for power cables for rated voltages up to 36 kV (Um = 42 kV), e.g. buried cables or cables installed in buildings, having a) conductors complying with IEC 60228 and IEC 60228A with cross-sectional areas 10 mm and greater for copper and 16 mm and greater for aluminium, b) a maximum continuous conductor temperature not exceeding 90 ℃. This standard is not applicable to connectors for overhead conductors, which are designed for special mechanical requirements, or to separable connectors with a sliding contact or multi-core connectors (i.e. ring connectors). Although it is not possible to define precisely the service conditions for all applications, two broad classes of connectors have been identified. Class A These are connectors intended for electricity distribution or industrial networks in which they can be subjected to short-circuits of relatively high intensity and duration. As a consequence, Class A connectors are suitable for the majority of applications. Class B These are connectors for networks in which overloads or short-circuits are rapidly cleared by the installed protective devices, e.g. fast-acting fuses. Depending on the application, the connectors are subjected to the following tests: Class A: heat cycle and short-circuit tests; Class B: heat cycle tests only. The object of this standard is to define the type test methods and requirements, which apply to compression and mechanical connectors for power cables with copper or aluminium conductors. Formerly, approval for such products has been achieved on the basis of national standards and specifications and/or the demonstration of satisfactory service performance. The publication of this IEC standard does not invalidate existing approvals. However, products approved according to these earlier standards or specifications cannot claim approval to this IEC standard unless specifically tested to it. After they have been made, these tests need not be repeated unless changes are made in the connector material, design or manufacturing process which might affect the performance characteristics.

Compression and mechanical connectors for power cables for rated voltages up to 36 kV (Um = 42 kV) - Test methods and requirements

ICS
29.120.20
CCS
K47
发布
2003-10-28
实施
2003-10-28

Live working - Insulating protective barriers above 1 kV

ICS
13.260
CCS
K47
发布
2003-10
实施
2003-10-01

This part of IEC 61249 gives requirements for properties of bismaleimide/triazine modified epoxide, or unmodified, woven E-glass reinforced laminate sheets of defined flam inability (vertical burning test), copper-clad in thicknesses of 0,05 mm to 3,2 mm. The flammability rating is achieved through the use of brominated fire retardants contained as an integral part of the epoxide polymeric structure. The glass transition temperature is defined to be 160 ℃ minimum. Some property requirements may have several classes of performance. The class desired needs to be specified on the purchase order, otherwise the default class of material may be supplied.

Materials for interconnection structures - Sectional specification set for reinforced base materials, clad and unclad - Reinforced base materials clad and unclad - Bismaleimide/triazine, modified epoxide or unmodified, woven E-glass reinforced laminated s

ICS
31.180
CCS
K47
发布
2003-08-14
实施
2003-08-14



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved