L17 电感器、变压器 标准查询与下载



共找到 443 条与 电感器、变压器 相关的标准,共 30

Instrument transformers - Part 2: Inductive voltage transformers - Supplement 1: Complementary marking of the rating plate for reduced rated power frequency withstand voltage

ICS
17.220.20;29.180
CCS
L17
发布
2008-12
实施

This part of IEC 62024 specifies the measuring methods of the rated direct current limits for small inductors. Standardized measuring methods for the determination of ratings enable users to accurately compare the current ratings given in various manufacturers' data books. This standard is applicable to leaded and surface mount inductors with dimensions according to IEC 62025-1 and generally with rated current less than 22 A, although inductors with rated current greater than 22 A are available that fall within the dimension restrictions of this standard (no larger than 12 mm x 12 mm footprint approximately). These inductors are typically used in DC to DC converters built on PCB, for electric and telecommunication equipment, and small size switching power supply units. The measuring methods are defined by the saturation and temperature rise limitations induced solely by direct current.

High frequency inductive components - Electrical characteristics and measuring methods - Part 2: Rated current of inductors for DC to DC converter

ICS
17.220.20;29.100.10
CCS
L17
发布
2008-10
实施
2008-10-10

This part of IEC 62024 specifies electrical characteristics and measuring methods for the nanohenry range chip inductor that is normally used in high frequency (over 100 kHz) range.

High frequency inductive components - Electrical characteristics and measuring methods - Part 1: Nanohenry range chip inductor

ICS
29.100.10
CCS
L17
发布
2008-08-29
实施
2008-08-29

This standard is intended for use as a basis for performance and interchangeability of equipment covered, and to assist in the proper selection of such equipment. Safety precautions are also addressed. This standard covers certain electrical, dimensional, and mechanical characteristics, and takes into consideration certain safety features of current and inductively coupled voltage transformers of types generally used in the measurement of electricity and the control of equipment associated with the generation, transmission, and distribution of alternating current.

Requirements for instrument transformers

ICS
17.220.20
CCS
L17
发布
2008-07-28
实施

This is corrigendum 1 of High frequency inductive components - Electrical characteristics and measuring methods - Part 1: Nanohenry range chip inductor.

High frequency inductive components - Electrical characteristics and measuring methods - Part 1: Nanohenry range chip inductor corrigendum 1

ICS
29.100.10
CCS
L17
发布
2008-07
实施

This European Standard specifies the requirements and tests for new three-phase voltage transformers with Um up to 52 kV and frequencies from 15 Hz to 100 Hz, for use with electrical instruments or electrical protective devices. NOTE Single-phase voltage transformers connected in a three-phase bank are not covered in this document.

Instrument transformers - Three-phase inductive voltage transformers having Um up to 52kV

ICS
17.220.20
CCS
L17
发布
2008-05-30
实施
2008-05-30

Describes the characteristics and classification of current transformers (cts) used for protective relaying.

Guide for the Application of Current Transformers Used for Protective Relaying Purpose

ICS
29.180
CCS
L17
发布
2008-05-01
实施

IEEE Standard for Practices and Requirements for Semiconductor Power Rectifier Transformers Amendment 1: Added Technical and Editorial Corrections

Practices and requirements for semiconductor power rectifier transformers; Amendment 1: Added technical and editorial corrections

ICS
29.180
CCS
L17
发布
2008-03-27
实施

This standard pertains to pulse transformers for use in electronic equipment. For the various types of these transformers, the peak power transmitted ranges from a few milliwatts to kilowatts; and the peak voltage transmitted ranges from a few volts to many kilovolts. The purpose of this standard is to provide a common ground between electronic system engineers and pulse transformer design engineers.

Standard for Pulse Transformers

ICS
17.220.20
CCS
L17
发布
2008-03-04
实施

Fixed inductors for electromagnetic interference suppression - Part 2: Sectional specification (IEC 60938-2:1999 + A1:2006); German version EN 60938-2:1999 + A1:2007

ICS
29.180
CCS
L17
发布
2008-02
实施
2008-02-01

Fixed inductors for electromagnetic interference suppression - Part 1: Generic specification (IEC 60938-1:1999 + A1:2006); German version EN 60938-1:1999 + A1:2007

ICS
29.180
CCS
L17
发布
2008-02
实施
2008-02-01

This part of IEC 62024 specifies electrical characteristics and measuring methods for the nanohenry range chip inductor that is normally used in high frequency (over 100 kHz) range.

High frequency inductive components - Electrical characteristics and measuring methods - Part 1: Nanohenry range chip inductor

ICS
29.100.10
CCS
L17
发布
2008-02
实施
2017-12-15

This standard is intended for use as a basis for performance and interchangeability of equipment covered, and to assist in the proper selection of such equipment. Safety precautions are also addressed. It covers certain electrical, dimensional, and mechanical characteristics, and takes into consideration certain safety features of current and inductively coupled voltage transformers of types generally used in the measurement of electricity and the control of equipment associated with the generation, transmission, and distribution of alternating current.

Standard Requirements for Instrument Transformers

ICS
17.220.20
CCS
L17
发布
2008
实施

This standard covers the general requirements, metering accuracy, thermal ratings, and dimensions applicable to current and inductively coupled voltage transformers for revenue metering.

Standard for Instrument Transformers for Revenue Metering 10 kV BIL Through 350 kV BIL (0.6 kV NSV Through 69 kV NSV)

ICS
17.220.20
CCS
L17
发布
2007-11-6
实施

本规范规定了按GB/T 14860-1993规定的能力批准程序放行的压电陶瓷变压器详细规范编制方法。本规范包括空白详细规范(BDS),空白详细规范规定了格式并规定了适合于这类型元件的试验,而最终选入检验的项目是由该规范的制定者决定的。本规范还规定了相应的额定值和特性。 本规范规定的元件主要用于背光电源、高压电源、负离子发生器、笔记本电脑、DVD/VCD、数码相机、大屏幕液晶电视等电子设备用的压电陶瓷变压器。

Sectional speciflcation for piemelectric ceramic transformer of assessed quality for use in electronic equipment for capability approval

ICS
29.100.10
CCS
L17
发布
2007-11-09
实施
2008-01-20

本标准适用于防汛抗旱和水文部门的实时水情信息交换。 其他部门的实时水情信息交换可参照本标准执行。 本标准的主要技术内容包括实时水情信息交换的基本规 定、方法和过程以及数据包

Protocol for exchange of real-time hydrological information

ICS
35.140
CCS
L17
发布
2007-10-08
实施
2008-01-08

This International Standard is applicable to newly manufactured instrument transformers with analogue or digital output for use with electrical measuring instruments or electrical protective devices having rated frequencies from 15 Hz to 100 Hz. This standard is a product family standard and covers general requirements only. For each kind of instrument transformer the product standard is composed by this standard and the relevant specific standard.

Instrument transformers - Part 1: General requirements

ICS
29.180
CCS
L17
发布
2007-10
实施

This part of IEC 62025 applies to fixed, surface mounted inductors and ferrite beads. Should conflict arise between these specifications and the detail specifications, the latter will take precedence. The object of this standard is to establish requirements for fixed, surface mounted inductors, to describe terms, to give recommendations for standard values and dimensions and to give guidance on fixed, surface mounted inductors.

High frequency inductive components - Non-electrical characteristics and measuring methods - Fixed, surface mounted inductors for use in electronic and telecommunication equipment

ICS
29.100.10
CCS
L17
发布
2007-09-28
实施
2007-09-28

General Instructions for CSA Standards are now called Updates. Please contact CSA Information Products Sales or visit www.ShopCSA.ca for information about the CSA Standards Update Service.

Three-phase, pad-mounted distribution transformers with separable insulated high-voltage connectors

ICS
CCS
L17
发布
2007-08-01
实施

The properties of the Logical Units’ user interfaces originating from a physical device are available using the GET IPaddr/2027_file command, where the IPaddr is the IP address of the physical device in dotted decimal notation in ASCII. Service devices shall return an XML document, see [6], describing all device supported Logical Units as the concatenation of all Logical Unit block descriptions. The schemas for the 2027 file and opcodes in Annex B are informative.

Digital STB Active Power Consumption Measurement

ICS
31.120
CCS
L17
发布
2007-07-01
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved