N20 电工仪器、仪表综合 标准查询与下载



共找到 450 条与 电工仪器、仪表综合 相关的标准,共 30

Safety requirements for electrical equipment for measurement, control, and laboratory use -- Part 1: General requirements

ICS
19.080;29.020;71.040.10
CCS
N20
发布
2019-03-20
实施

Equipment included in scope This part of IEC 61010 applies to equipment intended for in vitro diagnostic (IVD) medical purposes@ including self-test IVD medical purposes. IVD medical equipment@ whether used alone or in combination@ is intended by the manufacturer to be used in vitro for the examination of specimens@ including blood and tissue samples@ derived from the human body@ solely or principally for the purpose of providing information concerning one or more of the following: a physiological or pathological state; or a congenital abnormality; the determination of safety and compatibility with potential recipients; the monitoring of therapeutic measures. Self-test IVD medical equipment is intended by the manufacturer for use by lay persons in a home environment. NOTE If all or part of the equipment falls within the scope of one or more other Part 2 standards of the IEC 61010 series as well as within the scope of this document@ consideration is given to those other Part 2 standards. Equipment excluded from scope equipment within the scope of IEC 61010-2-081 unless it is specifically intended by the manufacturer to be used for in vitro diagnostic examination. Object Aspects included in scope biohazards; hazardous chemical substances. Aspects excluded from scope the handling or manipulation outside the equipment of material under analysis. NOTE Requirements covering these subjects are the responsibility of committees preparing the relevant standards.

Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-101: Particular requirements for in vitro diagnostic (IVD) medical equipment

ICS
11.040.55;11.100.10;19.080
CCS
N20
发布
2018-10-00
实施
2018-10-09

Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-201 : particular requirements for control equipment

ICS
25.040.40;35.240.50
CCS
N20
发布
2018-06-22
实施
2018-09-22

Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement; Amendment 1

ICS
19.080
CCS
N20
发布
2018-05-01
实施
2018-06-01

Power isolation sensor

ICS
17.220.20
CCS
N20
发布
2017-11-07
实施
2018-04-01

IEC 60051 is published in separate parts according to the following structure and under the general title Direct acting indicating analogue electrical measuring instruments and their accessories. Part 1: Definitions and General Requirements Common to all Parts. Part 2: Special Requirements for Ammeters and Voltmeters. Part 3: Special Requirements for Wattmeters and Varmeters. Part 4: Special Requirements for Frequency Meters. Part 5: Special Requirements for Phase Meters, Power Factor Meters and Synchroscopes. Part 6: Special Requirements for Ohmmeters (Impedance Meters) and Conductance Meters. Part 7: Special Requirements for Multi-function Instruments. Part 8: Special Requirements for Accessories. Part 9: Recommended Test Methods. Parts 2 to 9 are not complete in themselves and shall be read in conjunction with this Part 1. All of these parts are arranged in the same format and a standard relationship between subject and clause number is maintained throughout. This re-arrangement will assist the reader of IEC 60051 to distinguish information relating to the different types of instruments.

Direct acting indicating analogue electrical measuring instruments and their accessories - Part 1: Definitions and general requirements common to all parts (IEC 60051-1:2016); German version EN 60051-1:2017

ICS
01.040.17;17.220.20
CCS
N20
发布
2017-11-01
实施
2017-11-01

Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test (IEC 61010-031:2015); German version EN 61010-031:2015, Corrigendum

ICS
19.080
CCS
N20
发布
2017-04
实施

Safety requirements for electrical equipment for measurement, control and laboratory use. Particular requirements for in vitro diagnostic (IVD) medical equipment

ICS
11.040.55;19.080;71.040.10
CCS
N20
发布
2017-03-31
实施
2017-03-31

This clause of Part 1 is applicable except as follows: Equipment included in scope Replacement: Replace the text with the following: This group safety publication is primarily intended to be used as a product safety standard for the products mentioned in the scope, but shall also be used by technical committees in the preparation of their publications for products similar to those mentioned in the scope of this standard, in accordance with the principles laid down in IEC Guide 104 and lSO/lEC Guide 51. This part of IEC 61010 specifies safety requirements for equipment having testing or measuring circuits which are connected for test or measurement purposes to devices or circuits outside the measurement equipment itself. These include measuring circuits which are part of electrical test and measurement equipment, laboratory equipment, or process control equipment. The existence of these circuits in equipment requires additional protective means between the circuit and an OPERATOR. NOTE These testing and measuring circuits can, for example: measure voltages in circuits of other equipment; measure temperature of a separate device via a thermocouple; measure force on a separate device via a strain gauge; inject a voltage onto a circuit to analyse a new design. Equipment having these testing and measuring circuits may be intended for performing tests and measurements on hazardous conductors, including MAINS conductors and telecommunication network conductors. See Annex BB for considerations of HAZARDS involved in various tests and measurements.

Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-030: Particular requirements for equipment having testing or measuring circuits

ICS
17.220.20
CCS
N20
发布
2017-01
实施

Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements

ICS
17.220.20;71.040.20
CCS
N20
发布
2017-01
实施

1. Equipment included in scope Addition: Add the following first paragraph: This group safety publication is primarily intended to be used as a product safety standard for the products mentioned in the scope, but shall also be used by technical committees in the preparation of their publications for products similar to those mentioned in the scope of this standard, in accordance with the principles laid down in IEC Guide 104 and lSO/lEC Guide 51.

Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements; Amendment 1

ICS
17.220.20;19.080;71.040.20
CCS
N20
发布
2016-12
实施
2017-01-12

本规范适用于频率在0.1 THz~10 THz、功率在0. 1 mW~3 mW范围内辐射型太赫兹功率计的校准。其他频段和功率范围的功率计可参照本规范执行。

Calibration Specification for Terahertz Radiation Power Meters

ICS
CCS
N20
发布
2016-11-30
实施
2017-02-28

Mineral insulated metal sheathed thermocouple cables and thermocouples

ICS
17.200.20
CCS
N20
发布
2016-10-28
实施
2016-10-28

Requirements for software for tests with impulse voltages and currents

ICS
17.220.20;19.080
CCS
N20
发布
2016-09-20
实施

Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test (IEC 61010-031:2015); German version EN 61010-031:2015

ICS
19.080
CCS
N20
发布
2016-07
实施

Equipment included in scope This part of IEC 61010 specifies general safety requirements for the following types of electrical equipment and their accessories@ wherever they are intended to be used. a) Electrical test and measurement equipment This is equipment which by electromagnetic means tests@ measures@ indicates or records one or more electrical or physical quantities@ also non-measuring equipment such as signal generators@ measurement standards@ power supplies for laboratory use@ transducers@ transmitters@ etc. NOTE 1 This includes bench-top power supplies intended to aid a testing or measuring operation on another piece of equipment. Power supplies intended to power equipment are within the scope of IEC 61558 (see 1.1.2 h)). This standard also applies to test equipment integrated into manufacturing processes and intended for testing manufactured devices. NOTE 2 Manufacturing test equipment is likely to be installed adjacent to and interconnected with industrial machinery in this application. b) Electrical industrial process-control equipment This is equipment which controls one or more output quantities to specific values@ with each value determined by manual setting@ by local or remote programming@ or by one or more input variables. c) Electrical laboratory equipment This is equipment which measures@ indicates@ monitors@ inspects or analyses materials@ or is used to prepare materials@ and includes in vitro diagnostic (IVD) equipment. This equipment may also be used in areas other than laboratories; examples include selftest IVD equipment to be used in the home and inspection equipment to be used to check people or material during transportation. Equipment excluded from scope This standard does not apply to equipment within the scope of: a) IEC 60065 (Audio@ video and similar electronic apparatus); b) IEC 60204 (Safety of machinery ?C Electrical equipment of machines); c) IEC 60335 (Household and similar electrical appliances); d) IEC 60364 (Electrical installations of buildings); e) IEC 60439 (Low-voltage switchgear and controlgear assemblies); f) IEC 60601 (Medical electrical equipment); g) IEC 60950 (Information technology equipment including electrical business equipment@ except as specified in 1.1.3); h) IEC 61558 (Power transformers@ power supply units and similar); i) IEC 61010-031 (Hand-held probe assemblies); j) IEC 61243-3 (Live working ?C Voltage detectors ?C Part 3: Two-pole low-voltage type). Computing equipment This standard applies only to computers@ processors@ etc. which form part of equipment within the scope of this standard or are designed for use exclusively with the equipment. NOTE Computing devices and similar equipment within the scope of IEC 60950 and conforming to its requirements are considered to be suitable for use with equipment within the scope of this standard. However@ some of the requirements of IEC 60950 for resistance to moisture and liquids are less stringent than those in this standard (see 5.4.4 second paragraph)). This group safety publication is primarily intended to be used as a product safety standard for the products mentioned in the scope@ but shall also be used by technical committees in the preparation of its publications for products similar to those mentioned in the scope of this standard@ in accordance with the principles laid down in IEC Guide 104 and lSO/lEC Guide 51. NOTE If all or part of the equipment falls within the scope of one or more other Part 2 standards of IEC 61010 as well as within the scope of this standard@ it will also need to meet the requirements of those other Part 2 standards. Equipment excluded from scope Addition: Add the following new item: aa) IEC 60034 (Rotating electrical machinery);

Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-020: Particular requirements for laboratory centrifuges

ICS
19.080;71.040.10;71.040.20
CCS
N20
发布
2016-05
实施
2016-05-31

Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-091: Particular requirements for cabinet X-ray systems (IEC 61010-2-091:2012); German version EN 61010-2-091:2012, Corrigendum to DIN EN 61010-2-091 (VDE 041

ICS
71.040.50
CCS
N20
发布
2016-02
实施

This part of IEC 60051 specifies definitions and general requirements for direct acting indicating analogue electrical measuring instruments and their accessories. This part applies to direct acting indicating analogue electrical measuring instruments, such as: ammeters and voltmeters; wattmeters and varmeters; frequency meters of pointer and vibrating-reed types; phasemeters, power-factor meters and synchroscopes; ohmmeters(impedance meters) and conductance meters; multi-function instruments of the above types. It also applies to; certain accessories used with these instruments, such as; shunts; series resistors and impedance elements; combination of the instruments and the accessories provided that the adjustments have been made for the combination; direct acting indicating electrical measuring instrument whose scale marks do not correspond directly to its electrical input quantity, provided that the relationship between them is known; instruments and accessories having electronic devices in their measuring and/or auxiliary circuits. These series standards do not apply to; special purpose instruments which are covered by their own IEC standards; special purpose devices which are covered by their own IEC standards when they are used as accessories. This standard does not specify requirements concerning dimensions of instruments or accessories (for the former, see IEC 60473).

Direct acting indicating analogue electrical measuring instruments and their accessories - Part 1: Definitions and general requirements common to all parts

ICS
01.040.17;17.220.20
CCS
N20
发布
2016-02
实施

Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-061: Particular requirements for laboratory atomic spectrometers with thermal atomization and ionization (IEC 61010-2-061:2015); German version EN 61010-2-06

ICS
71.040.50
CCS
N20
发布
2016-02
实施

Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-051: Particular requirements for laboratory equipment for mixing and stirring (IEC 61010-2-051:2015); German version EN 61010-2-051:2015

ICS
71.040.20;71.040.50
CCS
N20
发布
2016-02
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved