共找到 286 条与 混凝土构配件 相关的标准,共 20 页
Building components (Concrete panel for wall) (Amendment 1)
Building components (Concrete panel for floor) (Amendment 1)
Building components (Concrete panel for roof) (Amendment 1)
1.1 This practice covers the determination of the acceptability of a concrete floor for the installation of resilient flooring. 1.2 This practice includes suggestions for the construction of a concrete floor to ensure its acceptability for installation of resilient flooring. 1.3 This practice does not cover the adequacy of the concrete floor to perform its structural requirements. 1.4 This practice covers the necessary preparation of concrete floors prior to the installation of resilient flooring. 1.5 This practice does not supersede in any manner the resilient flooring or adhesive manufacturer''s written instructions. Consult the individual manufacturer for specific recommendations. 1.6 Although carpet tiles, carpet, wood flooring, coatings, films, and paints ae not specifically intended to be included in the category of resilient floor coverings, the procedures included in this practice may be useful for preparing concrete floors to receive such finishes. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See 5.1, 7.1.1, and 7.1.2 for specific warning statements. 1.8 The values stated in inch-pound units are to be regarded as standard. The values in parentheses are mathematical conversions to SI units and are provided for information only.
Standard Practice for Preparing Concrete Floors to Receive Resilient Flooring
Chimneys - System chimneys with clay/ceramic flue liners - Part 2 : requirements and test methods under wet conditions.
Chimneys - System chimneys with clay/ceramic flue liners - Part 2 : requirements and test methods under wet conditions.
This document specifies the requirements for reinforced and prestressed precast concrete floor slats used in slatted floors for the housing of livestock and provides for the evaluation of conformity of these products. This document does not cover slats for loadings other than stock and stockmen.
Precast concrete products - Floor slats for livestock
This European Standard specifies the requirements and test methods for multiwall soot fire resistant system chimneys, working under dry conditions, with corrosion resistance 3, with negative pressure (see EN 1443) in which the products of combustion are conveyed to the atmosphere through clay/ceramic flue liners. Marking and inspection are also covered by this standard. This standard does not apply to structurally independent (free standing or self-supporting) system chimneys. A soot fire resistant system chimney has the following items where appropriate: -- clay/ceramic flue liners; -- Insulation layer; -- outer walls; -- mortar for jointing flue liners; -- mortar for jointing outer walls; -- terminal; -- chimney base; -- cladding; -- opening section; -- cleaning and inspection door; -- distance piece; -- reinforcement. The soot fire resistant chimney covers a combination of compatible chimney components, obtained or specified from one manufacturing source with product responsibility for the whole chimney.
Chimneys - System chimneys with clay/ceramic flue liners - Part 1: Requirements and test methods for sootfire resistance; German version EN 13063-1:2005+A1:2007
This product standard specifies the requirements and test methods for dry (designated D) and/or wet (designated W) air flue system chimneys, including terminals in which the products of combustion are conveyed to the atmosphere through clay/ceramic flue liners and combustion air is conveyed to suitable room-sealed appliance through an air duct or an air gap. It also specifies the requirements for marking, manufacturer’s instructions, product information and evaluation of conformity. An air flue system chimney is made of the following components where appropriate: - clay/ceramic flue liners; - insulation layer; - outer walls; - mortar for jointing flue liners; - acid resistant mortar or elastomeric sealant for jointing flue liners; - mortar for jointing outer walls; - terminal; - chimney base; - pressure equalizing opening; - airduct; - air gap; - cladding; - cleaning and inspection door; - distance piece; - reinforcement. The air flue system chimney covers a combination of compatible chimney components obtained or specified from one manufacturing source, with product responsibility for the whole chimney
Chimneys - System chimneys with clay/ceramic flue liners - Part 3: Requirements and test methods for air flue system chimneys; German version EN 13063-3:2007
This European Standard specifies the requirements and test methods for multiwall system chimneys working under wet conditions (in the following expressed as "wet chimney") with pressure type N1, N2 or P1 according to EN 1443 and a working temperature below or equal T600 according to EN 13063-1:2005+A1 in which the products of combustion are conveyed to the atmosphere through clay/ceramic flue liners. Marking and inspection are also covered by this document. This European Standard does not apply to structurally independent (free standing or self-supporting) system chimneys. The wet chimney may comprise the following appropriate components: -- clay/ceramic flue liners; -- insulation layer; -- outer walls; -- acid resistant mortar for jointing flue liners or elastomeric sealant; -- mortar forjointing outer walls; -- terminal; -- chimney base; -- condensate collector; -- condensate outlet; -- cladding; -- opening section; -- cleaning and inspection door; -- distance piece; -- reinforcement. The wet system chimney covers a combination of compatible chimney components, obtained or specified from one manufacturing source with product responsibility for the whole system chimney. NOTE This document does not cover soot fire resistance chimneys.
Chimneys - System chimneys with clay/ceramic flue liners - Part 2: Requirements and test methods under wet conditions; German version EN 13063-2:2005+A1:2007
DTU 43.1 - Building works - Impermeability of flat roofs and inclined roofs with a masonry structural member in a low-land climate - Part 2 : contract bill of special clauses.
Chimneys - Clay/ceramic flue liners - Requirements and test methods; Amendment A20
この規格は,石灰質原料及びけい酸質原料を主原料とし,オートクレーブ養生した軽量気泡コンクリート(以下,ALCという。)による製品のうち,鉄筋などの補強材で補強した,主として建築物などに用いるパネル(以下,パネルという。)について規定する。
Autoclaved lightweight aerated concrete panels
Precast concrete products - Bridge elements.
Precast concrete product - Ribbed floor elements.
Precast concrete product - Ribbed floor elements.
This European standard specifies particular requirements and performance concrete chimneys. It identifies requirements to ensure the mechanical resistance and stability of concrete chimneys in accordance with the general requirements given in EN 13084-1. As for chimneys attached to buildings the criteria given in Clause 1 of EN 13084-1-2000 apply. Unless otherwise stated in the following clauses the basic standard for the design of concrete strutures, EN1992-1-1, applies.
Free-standing chimneys - Part 2: Concrete chimneys; English version of DIN EN 13084-2:2007-08
Chimneys - Clay/ceramic flue liners - Requirements and test methods (including corrigendum AC:1999 and amendment A1:2002); German version EN 1457:1999 + AC:1999 + A1:2002, Corrigenda to DIN EN 1457:2003-04; German version EN 1457:1999/A1:2002/AC:2007
Chimneys - Components - Flue liners; German version EN 1857:2003, Corrigenda to DIN EN 1857:2003-11; German version EN 1857:2003/AC:2007
Copyright ©2007-2022 ANTPEDIA, All Rights Reserved