GB 7000.1-2007
Luminaires.Part 1:General requirements and tests (English Version)

GB 7000.1-2007
Standard No.
GB 7000.1-2007
Language
Chinese, Available in English version
Release Date
2007
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Status
 2017-01
Replace By
GB 7000.1-2015
Latest
GB/T 7000.1-2023
Replace
GB 7000.1-2002
Scope
This part of GB 7000 specifies the general requirements for lamps using electric light sources with a power supply voltage not exceeding 1000 V. The requirements and related tests proposed in this section include: classification, marking, mechanical structure and electrical structure. Each chapter of this part should be read together with Chapter 0 and other relevant chapters cited. Other parts of GB 7000 specify the specific requirements for a specific type of luminaire or a group of luminaires with a supply voltage not exceeding 1 000 V. For revision purposes, these sections are published separately, and additional sections are added when required. It should be noted that this section includes all aspects of safety (electrical, thermal and mechanical) requirements. The photometric data of luminaires is considered by the International Commission on Illumination (CIE), so this part does not involve. This standard covers requirements for luminaires with igniters whose nominal impulse voltage peak values do not exceed the values in Table ll.3. These requirements apply to luminaires with ignitors incorporated in the ballast as well as luminaires with ignitors separate from the ballast. Requirements for luminaires with triggers incorporated in the luminaire are under consideration. This section contains requirements for semi-luminaires. In general, this section includes safety requirements for luminaires. The purpose of this part is to provide a set of requirements and tests applicable to most types of lamps, and is referenced by the specific technical requirements of other parts of GB 7000. Therefore, this part itself should not be regarded as a regulation for any type of lamps. The terms of this part are only applicable to specific types of lamps within the scope determined by other parts of GB 7000. When other parts of GB 7000 refer to the requirements of a certain chapter of this part, it stipulates the applicability, test sequence and some necessary additional requirements of this chapter. The serial numbers in this section have no special meaning, and the sequence of applicable clauses is specified in other parts of GB 7000 corresponding to each type of luminaire or a group of luminaires. Other parts of GB 7000 are independent and do not refer to other parts in the series. Other parts of GB 7000 refer to the requirements of a certain chapter of this part. When the sentence "Apply the requirements of Chapter ... in GB 7000.1" appears, it means: Except for the requirements of specific types of lamps that are obviously not applicable to other parts of GB 7000, All requirements of this chapter of this part apply. For explosion-proof lamps covered by IEC 60079, in addition to the requirements of IEC 60079, they must also meet the requirements of relevant parts of GB 7000. When there is a conflict between GB 7000 and IEC 60079, the provisions of IEC 60079 shall be given priority. According to the IEC guidelines, the new IEC standards are divided into safety standards or performance standards. The "lamp design information" in the light source safety standard is given for the safety work of the light source. When testing the lamps according to this part, it should be regarded as a normative appendix. Pay attention to the light source performance standards contained in the "luminaire design information", these requirements should be followed in order to make the light source work normally, but this part does not require the light source performance test as part of the type test approval of the luminaire. The standard contains revisions and modifications based on continual improvement to take account of safety improvements brought about by the state of the art. Regional standardization bodies may state in their derived standards that products complying with the manufacturer's or the standardization body's earlier documentation are covered. It may be required in these declarations that, for such products, these earlier standards may continue to be used in production until the date when the new standard must be used.

GB 7000.1-2007 Referenced Document

  • GB 1002 Types, basic parameters and dimensions of single-phase plugs and sockets for household and similar purposes*2008-09-24 Update
  • GB 1003 Three phases plugs and socket-outlets for household and similar purposes.Types, basic parameters and dimensions*2008-09-24 Update
  • GB 1312 Lampholders for tubular fluorescent lamps and starterholders
  • GB 14196.2 Incandescent lamps.Safety specifications.Part 2:Tungsten halogen lamps for domestic and similar general lighting purposes*2008-12-30 Update
  • GB 15092.1-2003 Switches for appliances-Part 1: General requirements
  • GB 17936 Bayonet Iampholders
  • GB 18774 Double-capped fluorescent lamps-safety specifications
  • GB 19510.1 Lamp controlgear-Part 1:General and safety requirements*2009-10-15 Update
  • GB 19510.10 Lamp controlgear-Part 10:Particular requirements for ballasts for discharge lamps(excluding fluorescent lamps)*2009-10-15 Update
  • GB 19510.11 Lamp controlgear-Part 11:Particular requirements for electronic invertors and convertors for high-frequency operation of cold start tubular discharge lamps(neon tubes)
  • GB 19510.12 Lamp controlgear--Part 12:Particular requirements for miscellaneous electronic circuits used with luminaires
  • GB 19510.13 Lamp controlgear.Part 13:Particular requirements for d.c.or a.c.supplecd electronic ballasts for discharge lamps(excluding fluorescent lamps)
  • GB 19510.14 Lamp controlgear-Part 14:Particular requirements for d.c.or a.c.supplied electronic controlgear for LED modules*2009-10-15 Update
  • GB 19510.2 Lamp controlgear-Part 2:Particular requirements for starting devices (other than glow starters)*2009-10-15 Update
  • GB 19510.210 Lamp controlgear.Part 2-10: Particular requirements for electronic invertors and convertors for high-frequency operation of cold start tubular discharge lamps (neon tubes)*2013-12-31 Update
  • GB 19510.3 Lamp controlgear-Part 3:Particular requirements for d.c.or a.c.supplied electronic step-down convertors for filament lamps *2009-10-15 Update
  • GB 19510.4 Lamp controlgear-Part 4:Particular requirements for a.c.supplied electronic ballasts for fluorescent lamps*2009-10-15 Update
  • GB 19510.5 Lamp controlgear--Part 5:Particular requirements for d.c.supplied electronic ballasts for general lighting
  • GB 19510.6 Lamp controlgear--Part 6:Particular requirements for d.c.supplied electronic ballasts for public transport lighting
  • GB 19510.7 Lamp controlgear--Part 7:Particular requirements for d.c.supplied electronic ballasts for aircraft lighting
  • GB 19510.8 Lamp controlgear-Part 8:Particular requirements for d.c.supplied electronic ballasts for emergency lighting *2009-10-15 Update
  • GB 19510.9 Lamp controlgear-Part 9:Particular requirements for ballasts for fluorescent lamps*2009-10-15 Update
  • GB 4208-1993 Degrees of protection provided by enclosure (IP code)
  • GB 5013.1 Rubber insulated cables of rated voltages up to and including 450/750V. Part 1: General requirements
  • GB 5013.2 Rubber insulated cables of rated voltages up to and including 450/750V. Part 2: Test methods
  • GB 5013.3 Rubber insulated cables of rated voltages up to and including 450/750V. Part 3: Heat resistant silicone insulated cables
  • GB 5013.4 Rubber insulated cables of rated voltages up to and including 450/750V. Part 4: Cords and flexible cables
  • GB 5013.5 Rubber insulated cables of rated voltages up to and including 450/750V. Part 5: Lift cables
  • GB 5013.6 Rubber insulated cables of rated voltages up to and including 450/750V. Part 6: Arc welding cables
  • GB 5013.7 Rubber insulated cables of rated voltages up to and including 450/750V. Part 7: Heat resistant ethylene-vinyl acetate rubber insulated cables
  • GB 5023.1 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V. Part 1: General requirements
  • GB 5023.2 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V. Part 2: Test methods
  • GB 5023.3 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V. Part 3: Non-sheathed cables for fixed wiring
  • GB 5023.4 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V. Part 4: Sheathed cables for fixed wiring
  • GB 5023.5 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V. Part 5: Flexible cables (cords)
  • GB 5023.6 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V. Part 6: lift cables and cables for flexible connection
  • GB 5023.7 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V. Part 7: Flexible cables screened and unscreened with two or more conductors
  • GB 7000.11-1999 Safety requirements for portable general purpose luminaires
  • GB/T 14472 Fixed capacitors for use in electronic equipment. Part 14: Sectional specification. Fixed capacitors for electromagnetic interference suppression and connection to the supply mains
  • GB/T 16935.1 Insulation coordination of equipment within low-voltage power supply systems Part 1: Principles, requirements and tests*2023-09-07 Update
  • GB/T 5169.5 Fire hazard testing for electric and electronic products—Part 5: Test flames—Needle-flame test method—Apparatus, confirmatory test arrangement and guidance*2020-11-19 Update
  • IEC 60061-2 Lamp caps and holders together with gauges for the control of interchangeability and safety – Part 2: Lampholders
  • IEC 60061-3 Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 3: Gauges
  • IEC 60065:2001 Audio, video and similar electronic apparatus - Safety requirements
  • ISO 4046-4:2002 Paper, board, pulps and related terms - Vocabulary - Part 4: Paper and board grades and converted products
  • ISO 75-2:1993 Plastics; determination of temperature of deflection under load; part 2: plastics and ebonite
  • QB 2276 Starters intended to be used in fluorescent lamps

GB 7000.1-2007 history


GB 7000.1-2007 -All Parts

GB 7000.1-2015 Luminaires - Part 1: General requirements and tests GB 7000.10-1999 Safety requirements for fixed general purpose luminaires GB 7000.11-1999 Safety requirements for portable general purpose luminaires GB 7000.12-1999 Safety requirements for recessed luminaires GB 7000.13-1999 Safety requirements for handlamps GB 7000.14-2000 Safety requirements for air-handling luminaires GB 7000.15-2000 Safety requirements of luminaires for stage lighting,television,film and photographic studios(outdoor and indoor) GB 7000.16-2000 Safety requirements for luminaires used in clinical areas of hospitals and health care buildings GB 7000.17-2003 Safety requirements for luminaries with limited surface temperatures GB 7000.18-2003 Safety requirements for extra low voltage lighting systems for filament lamps GB 7000.19-2005 Safety requirements for photo and film luminaires(non-professional) GB 7000.2-2008 Luminaires.Part 2-22:Particular requirements.Luminaires for emergency lighting GB 7000.201-2008 Luminaires.Part 2-1:Particular requirements.Fixed general purpose luminaires GB 7000.202-2008 Luminaires.Part 2-2:Particular requirements.Recessed luminaires GB 7000.203-2013 Luminaires.Part 2-3 : Particular requirements.Luminaires for road and street lighting GB 7000.204-2008 Luminaires.Part 2-4:Particular requirements.Portable general purpose luminaires GB 7000.207-2008 Luminaires.Part 2-7:Particular requirements.Portable luminaries for garden use GB 7000.208-2008 Luminaires.Part 2-8:Particular requirements.Handlamps GB 7000.211-2008 Luminaires.Part 2-11:Larticular requirements-Aquarium luminaires GB 7000.212-2008 Luminaires.Part 2-12:Particular requirements.Mains socket-outlet mounted nightlights GB 7000.213-2008 Luminaires.Part 2-13:Particular requirements.Ground recessed luminaires GB 7000.214-2015 Luminaires - Part 2-14: Luminaires with special requirements for the use of cold-cathode tubular discharge lamps (neon lamps) and similar equipment GB 7000.217-2008 Luminaires.Part 2-17:Particular requirements.Luminaires for stage lighting,television,film and photographic studios(outdoor and indoor) GB 7000.218-2008 Luminaires.Part 2-18:Particular requirements.Luminaries for swimming pools and similar application GB 7000.219-2008 Luminaires.Part 2-19:Particular requirements.Air-handling luminaires GB 7000.225-2008 Luminaires.Part 2-25:Particular requirements.luminaires used in clinical areas of hospital and health care buildings GB 7000.3-1996 Safety requirements of portable luminaires for garden use GB 7000.4-2007 Luminaires.Part 2-10:Particular requirements.Portable luminaires for children GB 7000.5-2005 Safety requirements of luminaires for road and street lighting GB 7000.6-2008 Luminaires.Part 2-6:Particular requirements.Luminaires with built-in transformers or convertors for filament lamps GB 7000.7-2005 Safety requirements for floodlights GB 7000.8-1997 Safety requirements of luminaires for swimming pools and similar applications GB 7000.9-2008 Luminaires.Part 2-20:Particular requirements.Lighting chains



Copyright ©2007-2024 ANTPEDIA, All Rights Reserved