29.035.20 塑料和橡胶绝缘材料 标准查询与下载



共找到 1692 条与 塑料和橡胶绝缘材料 相关的标准,共 113

本文件规定了额定电压35kV及以下挤包绝缘电缆用交联型、热塑型聚烯烃类半导电屏蔽料的技术要求、试验方法、检验规则、包装、标志、运输和贮运。 本文件适用于聚烯烃类为基料,掺有交联剂和其他助剂经塑化造粒制成的交联型或热塑型的半导电屏蔽料。

Semi-conductive shielding material for extruded insulated cables with rated voltage 35kV and below

ICS
29.035.20
CCS
C292
发布
2021-07-13
实施
2021-07-13

本文件规定了35 kV及以下交联聚乙烯绝缘电线电缆用可交联聚乙烯绝缘料的技术要求、试验方法、检验规则、包装、标志、运输和贮存。 本文件适用于以低密度聚乙烯为基料、掺有交联剂等助剂经塑化造粒制成的过氧化物交联聚乙烯、硅烷交联聚乙烯和辐照交联聚乙烯的绝缘料。其适用范围为: (1~35)kV 过氧化物交联聚乙烯绝缘料; (1~35)kV 硅烷交联聚乙烯绝缘料; (1~10)kV 辐照交联聚乙烯绝缘料。

Cross-linkable polyethylene insulating material for wire and cable

ICS
29.035.20
CCS
C292
发布
2021-07-13
实施
2021-07-13

1.1?This specification covers thermoplastic chlorinated polyethylene (CPE) compounds suitable for use as an outer covering or jacket on electrical cables. 1.2?These jacket materials are suitable for use on cables which will be installed at temperatures above –35 ��C. 1.3?The v

Standard Specification for Thermoplastic Chlorinated Polyethylene (CPE) Jacket for Wire and Cable

ICS
29.035.20
CCS
发布
2021-07-01
实施

This specification covers a thermoplastic poly(vinyl chloride) insulation for wire and cable at the prescribed temperature. This insulation is recommended for use in power and control circuits at the specified thickness and voltage ratings and to dry locations. Tests are done on insulated wire or cable in this specification solely to determine the relevant property of the insulation material and not to test the conductor or completed cable. The insulation shall conform to the physical property requirements prescribed for the following: (1) tensile strength and elongation for unaged specimen and aged (using air oven test) tubular and buffed die-cut specimen, (2) heat shock, (3) heat distortion, (4) vertical flame test, (5) tensile strength and elongation for oil resistance test, and (6) cold bond test. Electrical tests shall be performed in the following order: ac voltage test, insulation resistance test, and dc voltage test. The insulation shall conform to the other electrical requirements such as accelerated water absorption (including permittivity and capacitance) and dielectric strength, and shall meet the prescribed thickness as well.

Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable, 75°C Operation

ICS
29.035.20
CCS
发布
2021-07-01
实施

Prescribes methods of test for the evaluation of water treeing in polyethylene (PE) and crosslinked polyethylene (XLPE) compounds, as a means to assess their relative performance under alternating (a.c.) electric stress, in the presence of water. Two methods are described, method I covering the evaluation of insulating materials alone, and method II covering the evaluation of insulating sandwiches consisting of an insulating material in intimate contact with semiconducting screens.

Methods of test for the evaluation of water treeing in insulating materials

ICS
29.035.20
CCS
发布
2021-07-01
实施

IEC 60684-3-280:2019 is available as IEC 60684-3-280:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 69684-3-280:2019 gives the requirements for heat-shrinkable, polyolefin sleeving, anti-tracking with a nominal shrink ratio of 3:1. This sleeving has been found suitable for use at temperatures up to 100 °C. Typically: medium wall, internal diameter up to 110 mm. This sleeving is normally supplied in the colours red or brown. Since these types of sleeving cover a significantly large range of sizes and wall thicknesses, Annex A (Table A.1) provides guidance on the range of sizes available. The actual size will be agreed between the user and the supplier. Materials which conform to this specification meet established levels of performance. However, the selection of a material by a user for a specific application will be based on the actual requirements necessary for adequate performance in that application and not based on this specification alone. This sleeving is designed to be used in medium voltage cable accessories and as such electrical performance willbe proven as part of the assembly. Examples of this are described in HD 629.1 and IEC 60502 (all parts). This second edition cancels and replaces the first edition published in 2010 and Amendment 1:2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - change of moulded plaque thickness for resistance to tracking and weathering tests to (6 ± 0,5) mm. Keywords: Heat-shrinkable, polyolefin sleeving, anti-tracking

Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 280: Heat-shrinkable, polyolefin sleeving, anti-tracking

ICS
29.035.20
CCS
发布
2021-07-01
实施

IEC 60674-3-8:2011+A1:2016 gives the requirements for balanced biaxially oriented polyethylene naphthalate (PEN) films for use as electrical insulation. This consolidated version consists of the first edition (2011) and its amendment 1 (2016). Therefore, no need to order amendment in addition to this publication.

Plastic films for electrical purposes - Part 3: Specifications for individual materials - Sheet 8: Balanced biaxially oriented polyethylene naphthalate (PEN) films used for electrical insulation

ICS
29.035.20
CCS
发布
2021-07-01
实施

Communication cables. Common design rules and construction. Polyethylene sheathing compounds

ICS
29.035.20
CCS
发布
2021-05-12
实施
2021-05-12

Communication cables – Part 2-27: Common design rules and construction – Halogen free polyolefin based sheathing compounds for cables having improved flame and fire properties (HFFR)

ICS
29.035.20
CCS
发布
2021-05-06
实施
2021-05-06

Communication cables – Part 2-24: Common design rules and construction – Polyethylene sheathing compounds

ICS
29.035.20
CCS
发布
2021-05-06
实施
2021-05-06

Silicone insulating sleeving by non-extrusion molding

ICS
29.035.20
CCS
发布
2021-04-21
实施

1.1?This specification applies to flexible, crosslinked and noncrosslinked poly(vinyl chloride) heat-shrinkable tubing for electrical insulating purposes. It is supplied in an expanded form and will shrink to its extruded diameter when heated. Note 1:?This standard is similar bu

Standard Specification for Crosslinked and Noncrosslinked Poly(Vinyl Chloride) Heat-Shrinkable Tubing for Electrical Insulation

ICS
29.035.20
CCS
发布
2021-01-01
实施

1.1?This specification covers flexible crosslinked chlorinated polyolefin heat-shrinkable tubing used for electrical insulating purposes. It is supplied in an expanded form and will shrink to the specified diameter when heated. Note 1:?This standard does not have a similar or eq

Standard Specification for Crosslinked Chlorinated Polyolefin Heat-Shrinkable Tubing for Electrical Insulation

ICS
29.035.20
CCS
发布
2021-01-01
实施

1.1?These test methods cover procedures for testing electrical insulating sleeving comprising a flexible tubular product made from a woven textile fibre base, such as cotton, rayon, nylon, or glass, thereafter impregnated, or coated, or impregnated and coated, with a suitable di

Standard Test Methods for Flexible Treated Sleeving Used for Electrical Insulation

ICS
29.035.20
CCS
发布
2021-01-01
实施

Polyvinyl chloride cable compounds with low fire hazard. General specifications

ICS
29.035.20
CCS
发布
2021-00-00
实施
2022-01-01

Specification for coatings for loaded printed wire boards(conformal coatings)-Part 1:Definitions, classification and general requirements

ICS
29.035.20
CCS
发布
2020-12-30
实施

Specification for coatings for loaded printed wire boards(conformal coatings)-Part 1:Definitions, classification and general requirements

ICS
29.035.20
CCS
发布
2020-12-30
实施

Flexible insulating sleeving — Part 3: Specifications for individual types of sleeving — Sheet 216: Heat-shrinkable, flame-retarded, limited-fire-hazard sleeving

ICS
29.035.20
CCS
发布
2020-12-28
实施

Flexible insulating sleeving — Part 3: Specifications for individual types of sleeving — Sheet 216: Heat-shrinkable, flame-retarded, limited-fire-hazard sleeving

ICS
29.035.20
CCS
发布
2020-12-28
实施

Flexible insulating sleeving — Part 3: Specifications for individual types of sleeving — Sheet 247: Heat-shrinkable, polyolefin sleeving, dual wall, not flame retarded, thick and medium wall

ICS
29.035.20
CCS
发布
2020-12-28
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号