29.035.20 塑料和橡胶绝缘材料 标准查询与下载



共找到 1692 条与 塑料和橡胶绝缘材料 相关的标准,共 113

1.1 These test methods cover the methods and procedures for testing electrically insulating and semi-conducting rubber tapes designed for splicing, terminating, and sheath repair of electrical wire and cable. 1.2 The test methods appear in the following sections: Section Referenced Documents 2 Conditioning 5 – 6 Dielectric Strength 35 – 40 Dimensions 11 – 16 Dissipation Factor 22 – 26 Elongation 17 – 21 Heat Exposure 46 – 49 Fusion 7 – 10 Ozone Resistance 41 – 45 Permittivity 22 – 26 Sample Requirements 4 Tensile Strength 17 – 21 Volume Resistivity 27 – 34 Ultraviolet and Weather Resistance 50 – 54 1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard. NOTE 1—There is no IEC equivalent to these methods. 1.4 Unless otherwise stated, measurements are made on tapes from which the removable separator has been removed. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific warning statement see 43.1. 1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Test Methods for Nonmetallic Semi-Conducting and Electrically Insulating Rubber Tapes

ICS
29.035.20
CCS
发布
2020-08-01
实施

1.1 This specification covers a thermoplastic jacketing compound for 2 to 35 kV wire and cable, of at least 0.030 in. (0.76 mm) nominal thickness, consisting substantially of pigmented polyethylene. 1.2 In many instances the jacket material cannot be tested unless it has been formed around a conductor or cable. Therefore, tests done on jacketed wire and cable in this specification are solely to determine the relevant property of the jacket material and not to test the jacketed conductor or completed cable. 1.3 Whenever two sets of values are presented, in different units, the values in the first set are the standard, while those in parentheses are for information only. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Thermoplastic Polyethylene Jacket for Electrical Wire and Cable

ICS
29.035.20
CCS
发布
2020-08-01
实施

1.1 These test methods evaluate the compatibility between cable filling or cable flooding compounds, or both, and polyolefin materials used in the manufacture of wire and cable that are usually in intimate contact with the filler or floodant, or both. 1.2 These test methods are useful to ensure compatibility and to verify that new formulations of filling or flooding compounds will have no deleterious effect upon the other polyolefin materials being used or, conversely, use these methods to ensure that other polyolefin wire and cable materials are evaluated for possible use not degraded by contact with fillers or floodants already in use. 1.3 Whenever two sets of values are presented, in different units, the values in the first set are to be regarded as standard. The values given in parentheses are mathematical conversions that are provided for information only and are not considered standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Test Methods for Evaluating Compatibility Between Cable Filling and Flooding Compounds and Polyolefin Wire and Cable Materials

ICS
29.035.20
CCS
发布
2020-08-01
实施

1.1 This specification covers an ozone-resistant insulating compound for electrical wire and cables 14 AWG and larger. This compound consists substantially of a thermoplastic elastomer. 1.2 This type of insulation is considered suitable for continuous operation at conductor temperatures not exceeding 90 °C in dry locations. Operating voltages are not to exceed 2000 V. The minimum installation temperature is –40 °C. 1.3 In many instances the insulation material cannot be tested unless it has been formed around a conductor or cable. Therefore, tests are done on insulated wire or cable in this specification solely to determine the relevant property of the insulation material and not to test the conductor or completed cable. 1.4 Whenever two sets of values are presented, in different units, the values in the first set are to be regarded as standard. The values given in parentheses are mathematical conversions that are provided for information only and are not considered standard. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Ozone-Resistant Thermoplastic Elastomer Insulation for Wire and Cable, 90 °C Operation

ICS
29.035.20
CCS
发布
2020-08-01
实施

Standard Specification for Thermoplastic Polyethylene Jacket for Electrical Wire and Cable

ICS
29.035.20
CCS
发布
2020-08-01
实施

Standard Specification for Track-Resistant Thermoplastic High-Density Polyethylene Insulation for Wire and Cable, 75 °C Operation

ICS
29.035.20
CCS
发布
2020-08-01
实施

1.1 This specification covers nonmetallic semi-conducting and electrical insulating tapes designed for the splicing and repair of electrical wire and cables operating at voltages up to 325 kV, phase to phase. 1.2 The SI values are the standard. The values stated in inch-pound units given in parentheses are for information purposes only. 1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Nonmetallic Semi-Conducting and Electrically Insulating Rubber Tapes

ICS
29.035.20
CCS
发布
2020-08-01
实施

1.1 This specification covers track-resistant thermoplastic high-density polyethylene insulation. Before application to the conductor, the insulation shall comply with the requirements of Specification D1248, Type III, Class C or D, Category 5, Grade E10, J4, or J5. The requirements of Specification D1248 shall not apply to the insulation removed from the conductor. 1.2 This type of insulation is considered suitable for use on wire or cable that will be used for continuous operation at conductor temperatures up to 75 °C. 1.3 This insulation is suitable for use on wire or in cable used for power transmission in overhead spaced-line service, installed at temperatures above −25 °C and exposed to sunlight and other atmospheric environments between −55 and +75 °C. 1.4 In many instances, the insulation cannot be tested unless it has been formed around a conductor. Therefore, tests done on insulated wire in this standard are solely to determine the relevant property of the insulation and not to test the conductor or completed cable. 1.5 Whenever two sets of values are presented, in different units, the values in the first set are to be regarded as standard. The values given in parentheses are mathematical conversions that are provided for information only and are not considered standard. 1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Track-Resistant Thermoplastic High-Density Polyethylene Insulation for Wire and Cable, 75 °C Operation

ICS
29.035.20
CCS
发布
2020-08-01
实施

1.1 This specification covers a low-density material based on poly (vinylidene fluoride) (PVDF), intended for use as jacketing material for wire and cable. 1.1.1 The material has a closed cell foam structure. 1.2 The jacketing material covered in this specification is intended for use in wires and cables in power-limited applications, such as optical fiber cables, communications cables, coaxial cables, or power limited fire alarm cables. The material is not intended for use in power cables. 1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Low-Density Poly (Vinylidene Fluoride) Based Material Intended for Use in Wire and Cable Jacketing

ICS
29.035.20
CCS
发布
2020-08-01
实施

1.1 This specification covers a track-resistant crosslinked polyethylene insulation, the base polymer which consists substantially of polyethylene or its copolymers. This insulation shall be carbon black pigmented, or colored and suitably protected to enable UV stability. 1.2 This type of insulation is considered suitable for use on wire or cable that will be used for continuous operation at conductor temperatures up to 90 °C. 1.3 This insulation is suitable for use on wire or in cable used for power transmission in overhead spaced-line service, installed at temperatures above −25° and exposed to sunlight and other atmospheric environments between −55 and +90 °C. 1.4 In many instances, the insulation cannot be tested unless it has been formed around a conductor. Therefore, tests done on insulated wire in this standard are solely to determine the relevant property of the insulation and not to test the conductor or completed cable. 1.5 Whenever two sets of values are presented, in different units, the values in the first set are to be regarded as standard. The values given in parentheses are mathematical conversions that are provided for information only and are not considered standard. 1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Track-Resistant Crosslinked Polyethylene Insulation for Wire and Cable, 90 °C Operation

ICS
29.035.20
CCS
发布
2020-08-01
实施

Standard Specification for Track-Resistant Crosslinked Polyethylene Insulation for Wire and Cable, 90 °C Operation

ICS
29.035.20
CCS
发布
2020-08-01
实施

1.1 In the US, this standard covers the following: a) Thermoplastic and rubber tapes for use as electrical insulation at not more than 600 V and at 80° C (176° F) and lower temperatures on joints and splices in wires and cables in accordance with NFPA 70. It is intended that rubber tape on a joint or splice be mechanically protected by a covering such as friction, PE (thermoplastic polyethylene), or PVC (polyvinyl chloride or a copolymer of vinyl chloride and vinyl acetate) tape. Thermoplastic tape is acceptable without the additional mechanical protection. b) The characteristic constituent of the thermoplastic tape covered in this Standard is either PVC (polyvinyl chloride or a copolymer of vinyl chloride and vinyl acetate), or PE (thermoplastic polyethylene). 1.2 In Canada, this standard covers the following: a) Thermoplastic and rubber tapes for use as electrical insulation at not more than 600 V and 80°C (176° F) and lower temperatures on joints and splices in wire and cables in accordance with the CSA C22.1. It is intended that rubber tape on a joint or splice be mechanically protected by a covering such as friction, PE (thermoplastic polyethylene), or PVC (polyvinyl chloride or a copolymer of vinyl chloride and vinyl acetate) tape. Thermoplastic tape is acceptable without the additional mechanical protection. b) The characteristic constituent of the thermoplastic tape covered in this Standard is PE (thermoplastic polyethylene). Requirements for PVC tape are covered by CSA C22.2 No. 197.

Polyvinyl Chloride, Polyethylene, and Rubber Insulating Tape

ICS
29.035.20
CCS
发布
2020-04-17
实施

Silicone insulating sleeving by non-extrusion molding

ICS
29.035.20
CCS
发布
2020-03-09
实施

Standard Specification for Rubber Insulating Blankets

ICS
29.035.20
CCS
发布
2020-02-01
实施

Specification for polyester fibre woven tapes — Part 1: Definitions, designation and general requirements

ICS
29.035.20
CCS
发布
20191231
实施
20191231

Specification for plastic films for electrical purposes — Part 3: Specifications for individual materials — Sheet 3: Requirements for polycarbonate(PC) films used for electrical insulation

ICS
29.035.20
CCS
发布
20191231
实施
20191231

Flexible insulating sleeving ― Part 3: Specifications for individual types of sleeving ― Sheet 165: Extruded polyolefin, flame retarded, limited fire hazard sleeving

ICS
29.035.20
CCS
发布
20191231
实施
20191231

Insulating materials — Industrial, rigid, moulded, laminated tubes and rods of rectangular and hexagonal cross-section based on thermosetting resins for electrical purposes — Part 1: Definitions, designations and general requirements

ICS
29.035.20
CCS
发布
20191231
实施
20191231

Specification for plastic films for electrical purposes — Part 3: Specifications for individual materials — Sheet 7: Requirements for fluoroethylenepropylene(FEP) films used for electrical insulation

ICS
29.035.20
CCS
发布
20191231
实施
20191231

Flexible insulating sleeving — Part 3: Specifications for individual types of sleeving — Sheet 229: Heat-shrinkable semi-flexible, polyvinylidene fluoride sleeving, flame retarded, fluid resistant, shrink ratio 2:1

ICS
29.035.20
CCS
发布
20191231
实施
20191231



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved