29.035.20 塑料和橡胶绝缘材料 标准查询与下载



共找到 1692 条与 塑料和橡胶绝缘材料 相关的标准,共 113

Flexible insulating sleeving — Part 3: Specifications for individual types of sleeving — Sheet 280: Heat-shrinkable, polyolefin sleeving, anti-tracking

ICS
29.035.20
CCS
发布
2020-12-28
实施

Flexible insulating sleeving — Part 3: Specifications for individual types of sleeving — Sheet 216: Heat-shrinkable, flame-retarded, limited-fire-hazard sleeving

ICS
29.035.20
CCS
发布
2020-12-28
实施

Flexible insulating sleeving — Part 3: Specifications for individual types of sleeving — Sheet 247: Heat-shrinkable, polyolefin sleeving, dual wall, not flame retarded, thick and medium wall

ICS
29.035.20
CCS
发布
2020-12-28
实施

Flexible insulating sleeving — Part 3: Specifications for individual types of sleeving — Sheet 280: Heat-shrinkable, polyolefin sleeving, anti-tracking

ICS
29.035.20
CCS
发布
2020-12-28
实施

Flexible insulating sleeving — Part 3: Specifications for individual types of sleeving — Sheet 247: Heat-shrinkable, polyolefin sleeving, dual wall, not flame retarded, thick and medium wall

ICS
29.035.20
CCS
发布
2020-12-28
实施

Flexible insulating sleeving-Part 3:Specifications for individual types of sleeving-Sheet 246:Heat-shrinkable polyolefin sleeving, dual wall, non-flame retarded

ICS
29.035.20
CCS
发布
20201214
实施
20201214

Specification for coatings for loaded printed wire boards(conformal coatings)-Part 3:Specification for individual materials-Sheet 1:Coatings for general purpose(class I) and for high reliability(class II)

ICS
29.035.20
CCS
发布
20201214
实施
20201214

Specification for coatings for loaded printed wire boards(conformal coatings)-Part 2:Methods of test

ICS
29.035.20
CCS
发布
20201214
实施
20201214

Flexible insulating sleeving — Part 3: Specifications for individual types of sleeving — Sheets 121 to 124: Extruded silicone sleeving

ICS
29.035.20
CCS
发布
2020-12-08
实施

Flexible insulating sleeving — Part 3: Specifications for individual types of sleeving — Sheets 121 to 124: Extruded silicone sleeving

ICS
29.035.20
CCS
发布
2020-12-08
实施

Heat shrinkable moulded shapes —Part 1: Definitions and general requirements

ICS
29.035.20
CCS
发布
2020-12-08
实施

Heat shrinkable moulded shapes —Part 1: Definitions and general requirements

ICS
29.035.20
CCS
发布
2020-12-08
实施

Standard Specification for Insulated Vinyl Siding

ICS
29.035.20
CCS
发布
2020-12-01
实施

This part of IEC 60684 gives the requirements for two types of heat-shrinkable, polyolefin sleeving for bus-bar insulation, with a nominal shrink ratio of 2,5:1.

Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 283: Heat-shrinkable, polyolefin sleeving for bus-bar insulation (IEC 60684-3-283:2019); German version EN IEC 60684-3-283:2019

ICS
29.035.20
CCS
发布
2020-12-01
实施
2020-12-01

This part of IEC 60684 gives the requirements for heat-shrinkable, polyolefin sleeving, anti-tracking with a nominal shrink ratio of 3:1.

Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 280: Heat-shrinkable, polyolefin sleeving, anti-tracking (IEC 60684-3-280:2019); German version EN IEC 60684-3-280:2019

ICS
29.035.20
CCS
G91
发布
2020-12-01
实施
2020-12-01

Standard Guide for Installation of Flexible Closed Cell Preformed Insulation in Tube and Sheet Form

ICS
29.035.20
CCS
发布
2020-11-01
实施

1.1 This specification covers silicone liquid for use in transformers, capacitors, and electronic assemblies as an insulating or cooling medium, or both. 1.2 Silicone liquid covered by this specification is polydimethylsiloxane having a nominal viscosity of 50 mm2 /s at 25°C and a fire point of 340°C or greater. This specification applies only to new silicone liquid. Information on in-service maintenance testing is available in appropriate guides.2 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Silicone Liquid Used for Electrical Insulation

ICS
29.035.20
CCS
发布
2020-11-01
实施

1.1 This specification covers a thermoplastic insulation which consists substantially of polyethylene. 1.2 This type of insulation is considered suitable for use on wire or cable that will be used for continuous operation at conductor temperatures up to 75 °C with a maximum conductor size of 1000 kcmil (507 mm2 ). The maximum voltage rating shall not exceed 35 000 V for power application or 9 000 V for series lighting. 1.3 In many instances the insulation material cannot be tested unless it has been formed around a conductor. Therefore, tests done on insulated wire or cable in this specification are solely to determine the relevant property of the insulation material and not to test the insulated conductor or completed cable. 1.4 Whenever two sets of values are stated, in different units, the values in the first set are regarded as standard, while the values in parentheses are provided for information only and are not considered standard. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Thermoplastic Polyethylene Insulation for Electrical Wire and Cable

ICS
29.035.20
CCS
发布
2020-10-01
实施

1.1 This specification covers a crosslinked polyethylene insulation for electrical wires and cables for conductor sizes 8 AWG (8.37 mm2 ) and larger. The base polymer of this insulation consists substantially of polyethylene. 1.2 This type of insulation is suitable for use on power cables in wet and dry locations at conductor temperatures not exceeding 90 °C for continuous operation, 130 °C for emergency overload conditions, and 250 °C for short-circuit conditions. It is considered suitable for all sizes and voltage classifications of singleand multiple-conductor power cables at voltage ratings of 2001 to 35 000 V phase-to-phase at the 100 % insulation level and at voltage ratings of 2001 to 25 000 V at the 133 % insulation level as listed in Table 1C of Test Methods D470. 1.3 Materials covered by this specification are not sunlightand weather-resistant unless they are carbon black pigmented or contain an additive system designed for this protection. 1.4 In many instances the insulation cannot be tested unless it has been formed around a conductor. Therefore, tests are done on insulated wire in this standard solely to determine the relevant property of the insulation and not to test the conductor or completed cable. 1.5 Whenever two sets of values are stated, in different units, the values in the first set are regarded as standard, while the values in parentheses are provided for information only and are not considered standard. 1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Crosslinked Polyethylene Insulation for Wire and Cable Rated 2001 to 35 000 V

ICS
29.035.20
CCS
发布
2020-10-01
实施

Standard Test Methods for Thermoplastic Insulations and Jackets for Wire and Cable

ICS
29.035.20
CCS
发布
2020-10-01
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号