L94 电子设备机械结构件 标准查询与下载



共找到 235 条与 电子设备机械结构件 相关的标准,共 16

Scope and object This part of IEC 60297 defines the interface dimensions between subracks and associated plug-in units using connectors as defined in PICMG-MTCA.0 (Fixed board) and IEC 61076-4-116 (Two part) and other two part connectors. For mechanical and climatic tests refer to IEC 61587-1. For electromagnetic shielding performance tests refer to IEC 61587-3.

Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-107: Dimensions of subracks and plug-in units, small form factor

ICS
31.240
CCS
L94
发布
2012-01
实施
2012-01-11

Mechanical structures for electronic equipment. Tests for IEC 60917 and IEC 60297. Seismic tests for cabinets and racks

ICS
31.240
CCS
L94
发布
2011-11-30
实施
2011-11-30

This part of IEC 61969 contains design guidelines for outdoor enclosures and is applicable over a wide field of mechanical@ electromechanical and electronic equipment and its installation where a modular design is used. The objective of this standard is to provide an overview of specifications for enclosures focused on requirements for outdoor applications for stationary use at non-weather protected locations. These enclosures are considered to contain any equipment and provide protection for the outdoor installed facilities against unwanted environmental impacts. The installed equipment may be@ but is not limited to@ subracks according to IEC 60917-2-2 or IEC 60297-3-101.

Mechanical structures for electronic equipment - Outdoor enclosures - Part 1: Design guidelines

ICS
31.240
CCS
L94
发布
2011-11
实施
2011-11-23

Mechanical structures for electronic equipment - Outdoor enclosures - Part 3: Environmental requirements, tests and safety aspects

ICS
31.240
CCS
L94
发布
2011-11
实施

This part of IEC 61969 applies to the design of enclosures for outdoor applications for stationary use at non-weatherprotected locations as defined in IEC 61969-1 Ed.2.0. The internal and external coordination dimensions are derived from IEC 60917-2. The internal dimensions meet the mounting dimensions of subracks in accordance with IEC 60917-2-2 and IEC 60297-3. The external dimensions@ compared to IEC 60917-2@ are partly increased in order to meet the design requirements of the outdoor specific conditions.

Mechanical structures for electronic equipment - Outdoor enclosures - Part 2: Coordination dimensions

ICS
31.240
CCS
L94
发布
2011-11
实施
2011-11-23

Mechanical structures for electronic equipment. Thermal management for cabinets in accordance with IEC 60297 and IEC 60917 series. Design guide. Method for the determination of forced air-cooling structure

ICS
23.120;31.240
CCS
L94
发布
2011-08-31
实施
2011-08-31

This part of IEC 61587 specifies seismic tests for cabinets and racks accommodated with IEC 60917 and 60297 series. It applies@ in whole or in part@ only to the mechanical structures of cabinets and racks for electronic equipment according to the above cited series of standards@ while it does not apply to the electronic equipment or systems deemed to be installed within these mechanical structures. This standard does not apply either to a cabinet or a rack having an anti-seismic isolation structure@ either external or internal. This standard aims to provide test conditions and criteria that constitute a reference to evaluate the ability of the mechanical structure of the cabinets or racks to acceptably withstand specified seismic intensities. For this purpose@ this standard specifies test specimen conditions@ such as dimensions (i.e. height@ width and depth) of the cabinet and the rack@ load distribution@ structural test condition and the RRS (required response spectra) of singleaxis or tri-axis acceleration as the seismic test wave condition. The single-axis or tri-axis acceleration is selectable.

IEC 61587-2, Ed. 2.0: Mechanical structures for electronic equipment - Tests for IEC 60917 and 60297 - Part 2: Seismic tests for cabinets and racks

ICS
31.240
CCS
L94
发布
2011-08
实施
2011-08-27

Mechanical structures for electronic equipment - Thermal management for cabinets in accordance with IEC 60297 and IEC 60917 series - Part 2: Design guide: Method for determination of forced air-coolin

ICS
31.240
CCS
L94
发布
2011-07-26
实施

Tests for enclosures for JIS C 6010 (all parts) and IEC 60297 (all parts) -- Part 3: Electromagnetic shielding performance tests for cabinets, racks and subracks

ICS
31.240
CCS
L94
发布
2011-01-20
实施

Tests for enclosures for JIS C 6010 (all parts) and IEC 60297 (all parts) -- Part 1: Climatic, mechanical tests and safety aspects for cabinets, racks, subracks and chassis

ICS
31.240
CCS
L94
发布
2011-01-20
实施

Tests for enclosures for JIS C 6010 (all parts) and IEC 60297 (all parts) -- Part 2: Seismic tests for cabinets and racks

ICS
31.240
CCS
L94
发布
2011-01-20
实施

Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-106: Adaptation dimensions for subracks and chassis applicable with metric cabinets or racks in accordance with IEC 60917-2-1 (IEC

ICS
31.240
CCS
L94
发布
2011-01
实施
2011-01-01

Modular order for the development of mechanical structures for electronic equipment practices - Part 2-4: Sectional specification - Interface coordination dimensions for the 25 mm equipment practice - Adaptation dimensions for subracks or chassis applicab

ICS
31.240
CCS
L94
发布
2011-01
实施
2011-01-01

Modular order for the development of mechanical structures for electronic equipment practices - Part 2-4 : sectional specification - Interface coordination dimensions for the 25 mm equipment practice - Adaptation dimensions for subracks or chassis applica

ICS
31.240
CCS
L94
发布
2010-07-01
实施
2010-07-23

Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-106 : adaptation dimensions for subracks and chassis applicable with metric cabinets or racks in accordance with IEC 60917-2-1.

ICS
31.240
CCS
L94
发布
2010-07-01
实施
2010-07-23

This part of IEC 60917 specifies dimensions for mounting flanges of metric subracks or chassis that are to be mounted into 19 in cabinets or racks. Additional dimensions for subracks or chassis are according to the IEC 60917 series, and for 19 in cabinets or racks to the IEC 60297 series. EMC, seismic climatic and environmental requirements and tests, are defined in the IEC 61587 series. The drawings used in this standard are not intended to indicate product design, only the specific dimensions that shall be used. The terminology used complies with IEC 60917-1.

Modular order for the development of mechanical structures for electronic equipment practices - Sectional specification - Interface coordination dimensions for the 25 mm equipment practice - Adaptation dimensions for subracks or chassis applicable in cabi

ICS
31.240
CCS
L94
发布
2010-05-31
实施
2010-05-31

This part of IEC 60297 specifies dimensions for mounting flanges of 19 in subracks or chassis that are to be mounted into metric cabinets or racks. Additional dimensions for subracks or chassis are according to the IEC 60297 series, and for metric cabinets or racks to the IEC 60917 series. EMC, seismic, climatic and environmental requirements and tests, are defined in the IEC 61587 series. The drawings used in this standard are not intended to indicate product design, only the specific dimensions that should be used. The terminology used complies with IEC 60917-1.

Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Adaptation dimensions for subracks and chassis applicable with metric cabinets or racks in accordance with IEC 60917-2-1

ICS
31.240
CCS
L94
发布
2010-05-31
实施
2010-05-31

This part of IEC 60191 provides standard outline drawings, dimensions, and recommended variations for all square ball grid array packages (BGA), whose terminal pitch is 1 mm or larger.

Mechanical standardization of semiconductor devices. General rules for the preparation of outline drawings of surface mounted semiconductor device packages. Design guide for ball grid array (BGA)

ICS
01.100.25;31.080.01;31.240
CCS
L94
发布
2010-04-30
实施
2010-04-30

This part of IEC 60917 specifies dimensions for mounting flanges of metric subracks or chassis that are to be mounted into 19 in cabinets or racks. Additional dimensions for subracks or chassis are according to the IEC 60917 series, and for 19 in cabinets or racks to the IEC 60297 series. EMC, seismic climatic and environmental requirements and tests, are defined in the IEC 61587 series. The drawings used in this standard are not intended to indicate product design, only the specific dimensions that shall be used. The terminology used complies with IEC 60917-1

Modular order for the development of mechanical structures for electronic equipment practices - Part 2-4: Sectional specification - Interface co-ordination dimensions for the 25 mm equipment practice - Adaptation dimensions for subracks or chassis applica

ICS
31.240
CCS
L94
发布
2010-03
实施
2013-07-12

This part of IEC 60297 specifies dimensions for mounting flanges of 19 in subracks or chassis that are to be mounted into metric cabinets or racks. Additional dimensions for subracks or chassis are according to the IEC 60297 series, and for metric cabinets or racks to the IEC 60917 series. EMC, seismic, climatic and environmental requirements and tests, are defined in the IEC 61587 series. The drawings used in this standard are not intended to indicate product design, only the specific dimensions that should be used. The terminology used complies with IEC 60917-1.

Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-106: Adaptation dimensions for subracks and chassis applicable with metric cabinets or racks in accordance with IEC 60917-2-1

ICS
31.240
CCS
L94
发布
2010-03
实施
2013-07-09



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved