L94 电子设备机械结构件 标准查询与下载



共找到 235 条与 电子设备机械结构件 相关的标准,共 16

This test method provides results that are related to the maximum temperature reached in a specific volume by a reacting liquid encapsulating compound, and the time from initial mixing to the time when this peak exothermic temperature is reached. This test method provides a means to measure the peak exothermic temperature of an encapsulating compound. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements see Section 8. Note 1There is no equivalent IEC standard.

Test Method for Exothermic Temperature of Encapsulating Compounds for Electronic and Microelectronic Encapsulation

ICS
31.240
CCS
L94
发布
2007-05-22
实施

This part of IEC 60297 covers the connector dependent interface dimensions for subracks and plug-in units in accordance with subracks of IEC 60297-3-101. In this part of IEC 60297, the two-part connectors of the series IEC 60603-2, IEC 61076-4-101, IEC 61076-4-113 are concerned. Since the connector specific standards contain the dimensions of the connectors only, it is the intention of this part of IEC 60297 to introduce the related subrack and plug-in unit interface dimensions if the connectors mentioned are applied. This standard will also provide dimensional guidelines for the implementation of other connectors by definition of the relationship between subrack mounting pitches and the position of board- type plug-in units and backplanes.

Mechanical Structures for Electronic Equipment. Dimensions of Mechanical Structures of the 482,6 mm (19 in) Series. Part 3-104: Connector Dependent Interface Dimensions of Subracks and Plug-in Units

ICS
31.240
CCS
L94
发布
2007-04-30
实施
2007-04-30

This part of IEC 60297 covers the connector dependent interface dimensions for subracks and plug-in units in accordance with subracks of IEC 60297-3-101. In this part of IEC 60297, the two-part connectors of the series IEC 60603-2, IEC 61076-4-101, IEC 61076-4-113 are concerned. Since the connector specific standards contain the dimensions of the connectors only, it is the intention of this part of IEC 60297 to introduce the related subrack and plug-in unit interface dimensions if the connectors mentioned are applied. This standard will also provide dimensional guidelines for the implementation of other connectors by definition of the relationship between subrack mounting pitches and the position of board- type plug-in units and backplanes.

Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-104: Connector dependent interface dimensions of subracks and plug-in units (IEC 60297-3-104:2006); German version EN 60297-3-104:

ICS
31.240
CCS
L94
发布
2007-03
实施
2007-03-01

This part of IEC 60917 provides additional dimensions for a modular range of subracks and associated plug-in units based on IEC 60917-2-2. A typical subrack consists of a frame design with mounting dimensions for installation into racks or cabinets in accordance with IEC 60917-2-1. The aperture dimensions of a subrack are specified in order to meet the mounting dimensions of front plug-in units.

Modular order for the development of mechanical structures for electronic equipment practices - Part 2-3: Sectional specification - Interface co-ordination dimensions for the 25 mm equipment practice - Extended detail specification - Dimensions for subrac

ICS
CCS
L94
发布
2007-02
实施
2007-02-01

This document defines the requirements for developing an Electronic Components Management Plan (ECMP), hereinafter also called the Plan, to assure customers and regulatory agencies that all of the electronic components in the equipment of the Plan owne

Standard for Preparing an Electronic Components Management Plan (proposed IEC 62239 equiv)

ICS
49.060
CCS
L94
发布
2007-01-19
实施

This standard applies to the interconnection of data terminal equipment and numerical control equipment at the tape reader interface. The data terminal would typically be connected to a remote data source/sink such as a computer.

Technical Guidelines for Aerospace and High Performance Electronic Systems Containing Lead-Free Solder and Finishes - Ballot Draft Copy To be published as GEIA-HB-0005-2

ICS
49.060
CCS
L94
发布
2007-01-01
实施

Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 - Part 3 : electromagnetic shielding performance tests for cabinets, racks and subracks.

ICS
31.240
CCS
L94
发布
2007-01-01
实施
2007-01-20

This part of IEC 61587 specifies the tests for empty cabinets and subracks concerning electromagnetic shielding performance, in the frequency range of 30 MHz to 2 000 MHz. Stipulated attenuation values are chosen for the definition of the shielding performance level of cabinets and subracks for the IEC 60297 and IEC 60917 series. The shielding performance levels are chosen with respect to the requirements of the typical fields of industrial application. They will support the measures to achieve electromagnetic compatibility but cannot replace the final testing of compliance of the equipped enclosure. The purpose of this standard is to ensure physical integrity and environmental performance of cabinets and subracks, taking into account the need for different levels of performance in different applications. It is intended to give the user a level of confidence in the selection of products to meet his specific needs. This standard in whole or part applies only to the empty enclosures, for example cabinets and subracks according to IEC 60297 and IEC 60917 and does not apply to the enclosures when electronic equipment is installed. This standard was developed in close relationship to IEC 61000-5-7 but with the specific focus on subracks and cabinets and the determination of performance levels at the chosen frequency range.

Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297: Electromagnetic shielding performance tests for cabinets, racks and sub-racks

ICS
31.240
CCS
L94
发布
2006-11-30
实施
2006-11-30

本规范规定了军用混合集成电路外壳生产和交付的通用要求,以及应满足的质量和可靠性保证要求。 本规范适用于军用混合集成电路、固体继电器、声表面波及带光纤器件的金属外壳,也适用于这类器件的陶瓷外壳。

General specification for packages of hybrid integrated circuits

ICS
CCS
L94
发布
2006-10-20
实施
2007-01-01

This standard applies to the interconnection of data terminal equipment and numerical control equipment at the tape reader interface. The data terminal would typically be connected to a remote data source/sink such as a computer.

I/O Buffer Information Specification (IBIS) Version 4.2

ICS
49.060
CCS
L94
发布
2006-09-01
实施

Semiconductor devices - Micro- electromechanical devices - Part 1 : terms and definitions.

ICS
01.040.31;31.080.01;31.220.01
CCS
L94
发布
2006-09-01
实施
2006-09-20

This part of IEC 60917 provides additional dimensions for a modular range of subracks and associated plug-in units based on IEC 60917-2-2. A typical subrack consists of a frame design with mounting dimensions for installation into racks or cabinets in accordance with IEC 60917-2-1. The aperture dimensions of a subrack are specified in order to meet the mounting dimensions of front plug-in units. This part of IEC 60917 comprises – additional dimensions for subracks and subrack associated plug-in units with injector/ extractor handle; – dimensions for basic electromagnetic shielding provisions; – dimensions of the key/coding system for subrack and plug-in units; – dimensions of the alignment pin for front panel and plug-in unit; – dimensions of electrostatic discharge provisions; – dimensions of rear-mounted plug-in units. Connector-related dimensions are given in Annex A. In order to ensure the compatibility of plug-in units into the subrack, inspection dimensions and connector-dependent dimensions are defined.

Modular order for the development of mechanical structures for electronic equipment practices - Sectional specification - Interface co-ordination dimensions for the 25 mm equipment practice - Extended detail specification - Dimensions for subracks, chassi

ICS
CCS
L94
发布
2006-08-31
实施
2006-08-31

This International Standard specifies a standard test piece, which is used to guarantee the propriety and accuracy of a tensile testing system for thin film materials with length and width under 1 mm and thickness under 10 µm, which are main structural materials for microelectromechanical systems (MEMS), micromachines and similar devices. This International Standard is based on such a concept that a tensile testing system can be guaranteed in propriety and accuracy, when the measured tensile strengths of the standard test pieces, whose tensile strength is pre-determined, are within the designated range. It also specifies the test pieces to minimize characteristics deviation among the pieces.

Semiconductor devices - Micro electromechanical devices - Part 3: Thin film standard test piece for tensile-testing

ICS
31.080.01;31.080.99;31.220.01
CCS
L94
发布
2006-08
实施
2006-08-16

This International Standard specifies the method for tensile testing of thin film materials with length and width under 1 mm and thickness under 10 µm, which are main structural materials for micro-electromechanical systems (MEMS), micromachines and similar devices. The main structural materials for MEMS, micromachines and similar devices have special features such as typical dimensions in the order of a few microns, a material fabrication by deposition, and a test piece fabrication by non-mechanical machining using etching and photolithography. This International Standard specifies the testing method, which enables a guarantee of accuracy corresponding to the special features.

Semiconductor devices - Micro-electromechanical devices - Part 2: Tensile testing method of thin film materials

ICS
31.080.01;31.080.99;31.220.01
CCS
L94
发布
2006-08
实施

This part of IEC 60297 covers only the additional interface dimensions for injector/extractor devices used with subracks and plug-in units according to IEC 60297-3-101. This standard may also be used in conjunction with IEC 60297-3-103.

Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Injector/extractor handle

ICS
31.240
CCS
L94
发布
2006-06-30
实施
2006-06-30

This part of IEC 60297 covers only the additional interface dimensions for an alignment pin and a keying device used with subracks and plug-in units according to IEC 60297-3-101. This standard may also be used in conjunction with IEC 60297-3-102.

Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Keying and alignment pin

ICS
31.240
CCS
L94
发布
2006-06-30
实施
2006-06-30

Due to a variety of real and potential health issues, many constituent materials used in the production of electronic products have come under scrutiny.

Standard for Mitigating the Effects of Tin Whiskers in Aerospace and High Performance Electronic Systems

ICS
49.060
CCS
L94
发布
2006-06-01
实施

This standard defines the objectives of, and requirements for, documenting processes that assure customers and regulatory agencies that AHP electronic systems containing Pb-free solder, piece parts, and boards will satisfy the applicable requirements fo

Performance Standard for Aerospace and High Performance Electronic Systems Containing Lead-free Solder

ICS
49.060
CCS
L94
发布
2006-06-01
实施

GB/T 18663的本部分规定了空的机柜和插箱在30 MHz~2 000 MHz频率范围内的电磁屏蔽性能试验,并为IEC 60297和IEC 60917系列机柜和插箱的屏蔽性能等级规定了所选用的衰减值。屏蔽性能等级根据工业应用中典型领域的要求选择,并支持这种测量以达到电磁兼容性,但不能取代装有设备的机壳最终的符合性试验。 本部分的目的是保证机柜和插箱的物理完整性和环境性能,考虑了不同应用中不同性能等级的需要。它的意图是让用户在选择产品水平以满足其特定的需要时具有信心。本部分仅全部或部分地适用于空机壳,例如符合IEC 60297和IEC 60917的机柜和插箱,而不适用于安装电子设备后的机壳。 本部分与IEC 61000—5—7紧密相关,但又特别关注机柜和插箱以及在所选择的频率范围内性能等级的确定。

Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 - Part 3: Electromagnetic shielding performance tests for cabinets, racks and subracks

ICS
31.240
CCS
L94
发布
2006-06
实施
2006-06-28

This standard applies to the interconnection of data terminal equipment and numerical control equipment at the tape reader interface. The data terminal would typically be connected to a remote data source/sink such as a computer.

Manual of Organization and Procedure

ICS
49.060
CCS
L94
发布
2006-05-01
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved